LINUX TRAP ID AND SNMP TRAPS REFERENCE GUIDE LEGAL NOTICES Copyright 2014-2015 Hewlett-Packard Development Company, L.P. Confidential computer software. Valid license from HP required for possession, use or copying. Consistent with FAR 12.211 and 12.212, Commercial Computer Software, Computer Software Documentation, and Technical Data for Commercial Items are licensed to the U.S. Government under vendor"s standard commercial license. The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. INTRODUCTION This guide contains a listing of the Linux Trap ID messages associated with SNMP traps that are generated by the HP Insight Management Agents for ProLiant servers running Linux. Each event entry has the corresponding SNMP trap number used by the agents. Where to go for additional help In addition to this guide, the following information sources are available: * User documentation * HP Insight Manager software Telephone numbers If you have purchased a Care Pack (service upgrade), call 1-800-633-3600. For more information about Care Packs, refer to the HP website (http://www.hp.com). In other locations, see the Contact HP worldwide (in English) webpage (http://welcome.hp.com/country/us/en/wwcontact.html). FOUNDATION AGENTS Trap IDs: 10003-11020 10003 - cmathreshd Log message: "%s: Variable %s has value %d <= %d." SNMP trap: cpqMe2RisingAlarm - 10003 in CPQTHRSH.MIB Symptom: Rising Threshold passed. An alarm entry has crossed its rising threshold.The instances of those objects contained within the variable list are those of the alarm entry which generated this trap. Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqMeAlarmVariable * cpqMeAlarmSampleType * cpqMeAlarmValue * cpqMeAlarmRisingThreshold * cpqMeAlarmOwner Supporting SNMP trap description: "[cpqMeAlarmOwner]: Variable [cpqMeAlarmVariable] has value [cpqMeAlarmValue] <= [cpqMeAlarmRisingThreshold]." 10004 - cmathreshd Log message: "%s: Variable %s has value %d <= %d." SNMP trap: cpqMe2FallingAlarm - 10004 in CPQTHRESH.MIB Symptom: Falling Threshold passed. An alarm entry has crossed its falling threshold. The instances of those objects contained within the variable list are those of the alarm entry which generated this trap. User action: None required Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqMeAlarmVariable * cpqMeAlarmSampleTyp * cpqMeAlarmValue * cpqMeAlarmFallingThreshold * cpqMeAlarmOwner Supporting SNMP trap description: "[cpqMeAlarmOwner]: Variable [cpqMeAlarmVariable] has value [cpqMeAlarmValue] <= [cpqMeAlarmFallingThreshold]." 10005 - cmathreshd Log message: "Rising Threshold Trap" "Alarm Variable %s" "Threshold Value %d" "Alarm Value %d" "Alarm Sample Type %s" "Alarm Owner %s" "Alarm Severity %d" "Alarm Description %s" SNMP trap: cpqMeRisingAlarmExtended - 10005 in CPQTHRSH.MIB Symptom: Rising Threshold passed. An alarm entry has crossed its rising threshold. The instances of those objects contained within the variable list are those of the alarm entry which generated this trap. User action: None required Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqMeAlarmVariable * cpqMeAlarmSampleType * cpqMeAlarmValue * cpqMeAlarmRisingThreshold * cpqMeAlarmOwner * cpqMeAlarmSeverity * cpqMeAlarmExtendedDescription Supporting SNMP trap description: "[cpqMeAlarmOwner]: Variable [cpqMeAlarmVariable] has value [cpqMeAlarmValue] >= [cpqMeAlarmRisingThreshold]." 10006 - cmathreshd Log message: "Falling Threshold Trap" "Alarm Variable %s" "Threshold Value %d" "Alarm Value %d" "Alarm Sample Type %s" "Alarm Owner %s" "Alarm Severity %d" "Alarm Description %s" SNMP trap: cpqMeFallingAlarmExtended - 10006 in CPQTHRSH.MIB Symptom: Falling Threshold passed. An alarm entry has crossed its falling threshold. The instances of those objects contained within the variable list are those of the alarm entry which generated this trap. Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqMeAlarmVariable * cpqMeAlarmSampleType * cpqMeAlarmValue * cpqMeAlarmFallingThreshold * cpqMeAlarmOwner * cpqMeAlarmSeverity * cpqMeAlarmExtendedDescription Supporting SNMP trap description: "[cpqMeAlarmOwner]: Variable [cpqMeAlarmVariable] has value [cpqMeAlarmValue] <= [cpqMeAlarmFallingThreshold]." 10007 - cmathreshd Log message: "%s: Variable %s has value %d >= %d." SNMP trap: cpqMeCriticalRisingAlarmExtended - 10007 in CPQTHRSH.MIB Symptom: Critical Rising Threshold passed. An alarm entry has crossed its critical rising threshold. The instances of those objects contained within the variable list are those of the alarm entry which generated this trap. User action: None required Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqMeAlarmVariable * cpqMeAlarmSampleType * cpqMeAlarmValue * cpqMeAlarmRisingThreshold * cpqMeAlarmOwner * cpqMeAlarmSeverity * cpqMeAlarmExtendedDescription Supporting SNMP trap description: "[cpqMeAlarmOwner]: Variable [cpqMeAlarmVariable] has value [cpqMeAlarmValue] >= [cpqMeAlarmRisingThreshold]." 10008 - cmathreshd Log message: "%s: Variable %s has value %d >= %d." SNMP trap: cpqMeCriticalFallingAlarmExtended - 10008 in CPQTHRSH.MIB Symptom: Critical Falling Threshold passed. An alarm entry has crossed its critical falling threshold. The instances of those objects contained within the variable list are those of the alarm entry which generated this trap. User action: None required Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqMeAlarmVariable * cpqMeAlarmSampleType * cpqMeAlarmValue * cpqMeAlarmFallingThreshold * cpqMeAlarmOwner * cpqMeAlarmSeverity * cpqMeAlarmExtendedDescription Supporting SNMP trap description: "[cpqMeAlarmOwner]: Variable [cpqMeAlarmVariable] has value [cpqMeAlarmValue] >= [cpqMeAlarmRisingThreshold]." 11003 - cmahostd Log message: "Compaq Generic Trap (11003): %s" SNMP trap: cpqHo2GenericTrap - 11003 in CPQHOST.MIB Symptom: Generic trap. Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqHoGenericData Supporting SNMP trap description: "[cpqHoGenericData]" 11020 - cmahostd Log message: "cpqHoMibHealthStatusArray has changed to the value : [cpqHoMibHealthStatusArray] SNMP trap: cpqHoMibHealthStatusArrayChangeTrap - 11020 in CPQHOST.MIB Symptom: A change in the cpqHoMibStatusArray has occured. Supporting SNMP trap data: * sysName * cpqHoMibHealthStatusArray Supporting SNMP trap description:cpqHoMibStatusArray has changed to the value [cpqHoMibHealthStatusArray] STORAGE AGENTS Trap IDs: 3016-3049 3016 - cmaidad Log message: "Controller Role Changes: Controller in slot [cpqDaCntlrSlot] is now active." SNMP trap: cpqDaCntlrActive - 3016 in CPQIDA.MIB Symptom: Controller Active. The agent has detected that a backup array controller in a duplexed pair has switched over to the active role. The variable cpqDaCntlrSlot indicates the active controller slot and cpqDaCntlrPartnerSlot indicates the backup. User action: Check the partner controller for problems. If this was the result of a user initiated switch over, no action is required. Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqDaCntlrSlot * cpqDaCntlrPartnerSlot Supporting SNMP trap description: "Controller in slot [cpqDaCntlrSlot] is now active." 3033 - cmaidad Log message: "Controller Status Change: [cpqDaCntlrHwLocation]. Status is now [cpqDaCntlrBoardStatus string]." SNMP trap: cpqDa6CntlrStatusChange - 3033 in CPQIDA.MIB Symptom: Controller Status Change. The agent has detected a change in the status of a drive array controller. The variable cpqDaCntlrBoardStatus indicates the current controller status. User action: If the board status is generalFailure(3), you might need to replace the controller. If the board status is cableProblem(4), check the cable connections between the controller and the storage system. Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqDaCntlrHwLocation * cpqDaCntlrIndex * cpqDaCntlrBoardStatus * cpqDaCntlrModel * cpqDaCntlrSerialNumber * cpqDaCntlrFWRev * cpqDaAccelTotalMemory Supporting SNMP trap description: "Status is now [cpqDaCntlrBoardStatus]." 3034 - cmaidad Log message: "Logical Drive Status Change: [cpqDaCntlrHwLocation], Drive: [cpqDaLogDrvIndex]. Status is now [cpqDaLogDrvStatus]." SNMP trap: cpqDa6LogDrvStatusChange - 3034 in CPQIDA.MIB Symptom: Logical Drive Status Change. The agent has detected a change in the status of a drive array logical drive. The variable cpqDaLogDrvStatus indicates the current logical drive status. Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqDaCntlrHwLocation * cpqDaLogDrvCntlrIndex * cpqDaLogDrvIndex * cpqDaLogDrvStatus Supporting SNMP trap description: "Status is now [cpqDaLogDrvStatus]." 3038 - cmaidad Log message: "Accelerator Board Status Change, slot number: [cpqDaCntlrSlot]. Status is now [cpqDaAccelStatus string]." SNMP trap: cpqDa6AccelStatusChange - 3038 in CPQIDA.MIB Symptom: Accelerator Board Status Change. The agent has detected a change in the status of an array accelerator cache board. The current status is represented by the variable cpqDaAccelStatus. User action: If the accelerator board status is permDisabled(5), you might need to replace the accelerator board. Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqDaCntlrHwLocation * cpqDaCntlrModel * cpqDaAccelCntlrIndex * cpqDaAccelSerialNumber * cpqDaAccelTotalMemory * cpqDaAccelStatus * cpqDaAccelErrCode Supporting SNMP trap description: "Status is now [cpqDaAccelStatus]." 3039 - cmaidad Log message: "Accelerator Board Bad Data, slot number: [cpqDaCntlrSlot]. Accelerator lost battery power. Data Loss possible." SNMP trap: cpqDa6AccelBadDataTrap - 3039 in CPQIDA.MIB Symptom: Accelerator Board Bad Data. The agent has detected an array accelerator cache board that has lost battery power. If data was being stored in the accelerator cache memory when the server lost power, that data has been lost. User action: Verify that no data was lost. Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqDaCntlrHwLocation * cpqDaCntlrModel * cpqDaAccelCntlrIndex * cpqDaAccelSerialNumber * cpqDaAccelTotalMemory Supporting SNMP trap description: "Accelerator lost battery power. Data Loss possible." 3040 - cmaidad Log message: "Accelerator Board Battery status change, slot number: [cpqDaCntlrSlot]. Battery failed. Status: %s." SNMP trap: cpqDa6AccelBatteryFailed - 3040 in CPQIDA.MIB Symptom: Accelerator Board Battery Failed. The agent has detected a battery failure associated with the array accelerator cache board. User action: Replace the Accelerator Cache Board. Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqDaCntlrHwLocation * cpqDaCntlrModel * cpqDaAccelCntlrIndex * cpqDaAccelSerialNumber * cpqDaAccelTotalMemory Supporting SNMP trap description: "Battery status is failed" 3041 - cmaidad Log message: " Tape Library Status Change, slot number: [cpqDaCntlrHwLocation], bus number [cpqDaTapeLibraryScsiBus], Target ID: [cpqDaTapeLibraryScsiTarget], Lun Number: [cpqDaTapeLibraryScsiLun]. Status is now [cpqDaTapeLibraryStatus]." SNMP trap: cpqDa6TapeLibraryStatusChange - 3041 in CPQIDA.MIB Symptom: "Tape Library Status Changed. This trap signifies that the agent has detected a change in the status of a tape library. The variable cpqDaTapeLibraryStatus indicates the current tape library status. The variable cpqDaTapeLibraryScsiTarget indicates the SCSI ID of the tape library. User action: If the tape library is failed, check the tape library front panel. Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqDaCntlrHwLocation * cpqDaTapeLibraryCntlrIndex * cpqDaTapeLibraryScsiBus * cpqDaTapeLibraryScsiTarget * cpqDaTapeLibraryScsiLun * cpqDaTapeLibraryModel * cpqDaTapeLibraryFWRev * cpqDaTapeLibrarySerialNumber * cpqDaTapeLibraryStatus Supporting SNMP trap description: " Tape Library Status Change, slot number: [cpqDaCntlrHwLocation], bus number: [cpqDaTapeLibraryScsiBus], Target ID: [cpqDaTapeLibraryScsiTarget], Lun Number: [cpqDaTapeLibraryScsiLun]. Status is now [cpqDaTapeLibraryStatus]." 3042 - cmaidad Log message: Tape Library Door Status Change, slot number: [cpqDaCntlrHwLocation], bus number [cpqDaTapeLibraryScsiBus], Target ID: [cpqDaTapeLibraryScsiTarget], Lun Number: [cpqDaTapeLibraryScsiLun]. Status is now [cpqDaTapeLibraryDoorStatus]". SNMP trap: cpqDa6TapeLibraryDoorStatusChange - 3042 in CPQIDA.MIB Symptom: Tape Library Door Status Change. This trap signifies that the agent has detected a change in the door status of a tape library. The variable cpqDaTapeLibraryDoorStatus indicates the current tape library door status. The variable cpqDaTapeLibraryScsiTarget indicates the the SCSI ID of the tape library. User action: If the tape library door is open, close the tape library door. Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqDaCntlrHwLocation * cpqDaTapeLibraryCntlrIndex * cpqDaTapeLibraryScsiBus * cpqDaTapeLibraryScsiTarget * cpqDaTapeLibraryScsiLun * cpqDaTapeLibraryModel * cpqDaTapeLibraryFWRev * cpqDaTapeLibrarySerialNumber * cpqDaTapeLibraryDoorStatus Supporting SNMP trap description: Tape Library Door Status Change, slot number: [cpqDaCntlrHwLocation], bus number [cpqDaTapeLibraryScsiBus], Target ID: [cpqDaTapeLibraryScsiTarget], Lun Number: [cpqDaTapeLibraryScsiLun]. Status is now [cpqDaTapeLibraryDoorStatus]". 3043 - cmaidad Log message: "Tape Drive Status Change, slot number: [cpqDaCntlrSlot], bus number: [cpqDaTapeDrvBusI ndex], drive ID: [cpqDaTapeDrvScsi IdI ndex]. Status is now [cpqDaTapeDrvStatus string]." SNMP trap: cpqDa6TapeDriveStatusChange - 3043 in CPQIDA.MIB Symptom: Tape Drive Status Change. The agent has detected a change in the status of a tape drive. The variable cpqDaTapeDrvStatus indicates the current tape status. The variable cpqDaTapeDrvScsiIdIndex indicates the SCSI ID of the tape drive. User action: If the tape is failed, check the tape and all SCSI connections. Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqDaCntlrHwLocation * cpqDaTapeDrvCntlrIndex * cpqDaTapeDrvBusIndex * cpqDaTapeDrvScsiIdIndex * cpqDaTapeDrvLunIndex * cpqDaTapeDrvName * cpqDaTapeDrvFwRev * cpqDaTapeDrvSerialNumber * cpqDaTapeDrvStatus Supporting SNMP trap description: "Status is now [cpqDaTapeDrvStatus] for a tape drive." 3044 - cmaidad Log message: "Tape Drive Cleaning Required, slot number: [cpqDaCntlrSlot], bus number: [cpqDaTapeDrvBusIndex], drive ID: [cpqDaTapeDrvScsiIdIndex]" SNMP trap: cpqDa6TapeDriveCleaningRequired - 3044 in CPQIDA.MIB Symptom: Tape Drive Cleaning Required trap. The agent has detected a tape drive that needs to have a cleaning tape inserted and run. This will cause the tape drive heads to be cleaned. Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqDaCntlrHwLocation * cpqDaTapeDrvCntlrIndex * cpqDaTapeDrvBusIndex * cpqDaTapeDrvScsiIdIndex * cpqDaTapeDrvLunIndex * cpqDaTapeDrvName * cpqDaTapeDrvFwRev * cpqDaTapeDrvSerialNumber Supporting SNMP trap description: "Cleaning is needed for the tape drive." 3045 - cmaidad Log message: "Tape Drive Cleaning Tape Needs Replacing, slot number: [cpqDaCntlrSlot], bus number: [cpqDaTapeDrvBusIndex], drive ID: [cpqDaTapeDrvScsiIdIndex]" SNMP trap: cpqDa6TapeDriveCleanTapeReplace - 3045 in CPQIDA.MIB Symptom: Tape Drive Cleaning Tape Needs Replacing. The agent has detected that an autoloader tape unit has a cleaning tape that has been fully used and needs to be replaced with a new cleaning tape. Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqDaCntlrHwLocation * cpqDaTapeDrvCntlrIndex * cpqDaTapeDrvBusIndex * cpqDaTapeDrvScsiIdIndex * cpqDaTapeDrvLunIndex * cpqDaTapeDrvName * cpqDaTapeDrvFwRev * cpqDaTapeDrvSerialNumber Supporting SNMP trap description: "Cleaning tape needs replacing" 3046 - cmidad Log message: "Physical Drive Status Change: [cpqDaCntlrHwLocation] [cpqDaPhyDrvLocationString]. Status is now [cpqDaPhyDrvStatus string]." SNMP trap: - cpqDa7PhyDrvStatusChange 3046 in CPQIDA.MIB Symptom: Physical Drive Status Changed. The agent has detected a change in the status of a drive array physical drive. The variable cpqDaPhyDrvStatus indicates the current physical drive status. User action: If the physical drive status is failed(3) or predictiveFailure(4), replace the drive." Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqDaCntlrHwLocation * cpqDaPhyDrvCntlrIndex * cpqDaPhyDrvIndex * cpqDaPhyDrvLocationString * cpqDaPhyDrvType * cpqDaPhyDrvModel * cpqDaPhyDrvFWRev * cpqDaPhyDrvSerialNum * cpqDaPhyDrvFailureCode * cpqDaPhyDrvStatus * cpqDaPhyDrvBusNumber Supporting SNMP trap description: "Physical Drive Status is now [cpqDaPhyDrvStatus]." 3047 - cmaidad Log message: "Spare Drive Status Change: [cpqDaCntlrHwLocation] [cpqDaSpareLocationString]. Status is now [cpqDaSpareStatus string]." SNMP trap: cpqDa7SpareStatusChange - 3047 in CPQIDA.MIB Symptom: Spare Drive Status Change. The agent has detected a change in the status of a drive array spare drive. The variable cpqDaSpareStatus indicates the current spare drive status. User action: If the spare drive status is failed, replace the drive. Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqDaCntlrHwLocation * cpqDaSpareCntlrIndex * cpqDaSparePhyDrvIndex * cpqDaSpareStatus * cpqDaSpareLocationString * cpqDaSpareBusNumber Supporting SNMP trap description: "Spare Status is now [cpqDaSpareStatus]." 3048 - cmaidad Log Message: "Partner Controller Status Change: [cpqDaCntlrPartnerSerialNumber]. Status is now [cpqDaCntlrPartnerBoardStatus]." SNMP trap: - cpqDaCntlrPartnerStatusChange 3048 in CPQIDA.MIB Symptom: Partner Controller Status Change.This trap signifies that the agent has detected a change in the status of a drive array partner controller. The variable cpqDaCntlrPartnerBoardStatus indicates the current partner controller status. The variable cpqDaCntlrSerialNumber indicates the controller.s serial number and cpqDaCntlrPartnerSerialNumber indicates the partner controller.s serial number. User action: Check the partner controller for problems. If lost communication with the partner controller is the result of a user initiated action, no remedial action is required." Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqDaCntlrHwLocation * cpqDaCntlrIndex * cpqDaCntlrModel * cpqDaCntlrSerialNumber * cpqDaCntlrPartnerSerialNumber * cpqDaCntlrPartnerBoardStatus Supporting SNMP trap description: "Partner Controller Status Change: [cpqDaCntlrPartnerSerialNumber]. Status is now [cpqDaCntlrPartnerBoardStatus]." 3049 - cmaidad Log Message: "Solid State Disk Wear Status Change (3049). Solid State Disk Wear Status is now [cpqDaPhyDrvSSDWearStatus]" SNMP trap: - cpqDaPhyDrvSSDWearStatusChange 3049 in CPQIDA.MIB Symptom: Solid State Disk Wear Status Change.This trap signifies that the agent has detected a change in the SSD wear status of a drive array physical drive. The variable cpqDaPhyDrvSSDWearStatus indicates the current SSD wear status. User Action: If the SSD wear status is ssdWearOut(6), replace the drive. Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqDaCntlrHwLocation * cpqDaPhyDrvCntlrIndex * cpqDaPhyDrvIndex * cpqDaPhyDrvModel * cpqDaPhyDrvFWRev * cpqDaPhyDrvSerialNum * cpqDaPhyDrvSSDWearStatus Supporting SNMP trap description: "Solid State Disk Wear Status Change (3049). Solid State Disk Wear Status is now [cpqDaPhyDrvSSDWearStatus]" Trap IDs: 5008-5026 5008 - cmascsid Log message: "Tape drive cleaning required: Status is now [cpqTapePhyDrvCondition]." SNMP trap: cpqTape3PhyDrvCleaningRequired - 5008 in CPQSCSI.MIB Symptom: Tape Drive Cleaning Required trap. The agent has detected a tape drive that needs to have a cleaning tape inserted and run. This will cause the tape drive heads to be cleaned. Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqTapePhyDrvCondition Supporting SNMP trap description: "Status is now [cpqTapePhyDrvCondition]." 5009 - cmascsid Log message: "Tape drive cleaning tape needs replacing. Status is now [cpqTapePhyDrvCondition]." SNMP trap: cpqTape3PhyDrvCleanTapeReplace - 5009 in CPQSCSI.MIB Symptom: Tape Drive Cleaning Tape Needs Replacing. The agent has detected that an autoloader tape unit has a cleaning tape that has been fully used and needs to be replaced with a new cleaning tape. Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqTapePhyDrvCondition Supporting SNMP trap description: "Status is now [cpqTapePhyDrvCondition]." 5013 - cmascsid Log message: "Tape library [cpqTapeLibrarySerialNumber] door opened" SNMP trap: cpqTape3LibraryDoorOpen - 5013 in CPQSCSI.MIB Symptom: Tape Library Door Open. The agent has detected that the door on an autoloader is open so the unit is not operational. Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqTapeLibrarySerialNumber Supporting SNMP trap description: "Tape library [cpqTapeLibrarySerialNumber] door opened" 5014 - cmascsid Log message: "Tape library [cpqTapeLibrarySerialNumber] door closed" SNMP trap: cpqTape3LibraryDoorClosed - 5014 in CPQSCSI.MIB Symptom: Tape Library Door Closed. The agent has detected that the door on an autoloader has closed. Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqTapeLibrarySerialNumber Supporting SNMP trap description: "Tape library [cpqTapeLibrarySerialNumber] door closed" 5018 - cmascsid Log message: "Tape Library Status Changed: Status is now [cpqTapeLibraryState]." SNMP trap: cpqTapeLibraryStatusChange - 5018 in CPQSCSI.MIB Symptom: Tape Library Status Change. The agent has detected a change in the status of a tape library. The current tape library status is indicated in the cpqTapeLibraryState variable. Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqTapeLibraryCntlrIndex * cpqTapeLibraryBusIndex * cpqTapeLibraryScsiIdIndex * cpqTapeLibraryLunIndex * cpqTapeLibraryName * cpqTapeLibraryFwRev * cpqTapeLibrarySerialNumber * cpqTapeLibraryState Supporting SNMP trap description: "Status is now [cpqTapeLibraryState]." 5019 - cmascsid Log message: "Tape Drive Status Changed: Status is now [cpqTapePhyDrvStatus]." SNMP trap: cpqTape5PhyDrvStatusChange - 5019 in CPQSCSI.MIB Symptom: Tape Drive Status Change. The agent has detected a change in the status of a tape drive. The current physical drive status is indicated in the cpqTapePhyDrvStatus variable. Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqTapePhyDrvCntlrIndex * cpqTapePhyDrvBusIndex * cpqTapePhyDrvScsiIdIndex * cpqTapePhyDrvLunIndex * cpqTapePhyDrvName * cpqTapePhyDrvFwRev * cpqTapePhyDrvSerialNumber * cpqTapePhyDrvStatus Supporting SNMP trap description: "Status is now [cpqTapePhyDrvStatus]." 5020 - cmascsid Log message: "Disk status changed from [previous cpqScsiPhyDrvStatus] to [current cpqScsiPhyDrvStatus]. Slot [cpqScsiPhyDrvCntlrIndex] port [cpqScsiPhyDrvBusIndex] id [cpqScsiPhyDrvIndex] ." SNMP trap: cpqScsi5PhyDrvStatusChange - 5020 in CPQSCSI.MIB Symptom: Physical Drive Status Change. The agent has detected a change in the status of a SCSI physical drive. The current physical drive status is indicated in the cpqScsiPhyDrvStatus variable. User action: None required Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqScsiPhyDrvStatus * cpqScsiPhyDrvCntlrIndex * cpqScsiPhyDrvBusIndex * cpqScsiPhyDrvIndex * cpqScsiPhyDrvVendor * cpqScsiPhyDrvModel * cpqScsiPhyDrvFWRev * cpqScsiPhyDrvSerialNum * cpqScsiPhyDrvOsName Supporting SNMP trap description: "Status is now [cpqScsiPhyDrvStatus]." 5022 - cmasasd Log message: "SAS Physical Drive Status Changed: Status changed from [previous cpqSasPhyDrvStatus] to [current cpqSasPhyDrvStatus]." SNMP trap: cpqSasPhyDrvStatusChange - 5022 in CPQSCSI.MIB Symptom: Physical Drive Status Change. The agent has detected a change in the status of a SAS or SATA physical drive. The current physical drive status is indicated in the cpqSasPhyDrvStatus variable. User action: None required Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqSasHbaHwLocation * cpqSasPhyDrvLocationString * cpqSasPhyDrvHbaIndex * cpqSasPhyDrvIndex * cpqSasPhyDrvStatus * cpqSasPhyDrvType * cpqSasPhyDrvModel * cpqSasPhyDrvFWRev * cpqSasPhyDrvSerialNumber * cpqSasPhyDrvSasAddress Supporting SNMP trap description: "Status is now [cpqSasPhyDrvStatus]." 5023 - cmasasd Log message: "SAS Logical Drive Status Changed: Status changed from [previous cpqSasLogDrvStatus] to [current cpqSasLogDrvStatus]." SNMP trap: cpqSasLogDrvStatusChange - 5023 in CPQSCSI.MIB Symptom: Logical Drive Status Change. The agent has detected a change in the status of a SAS or SATA logical drive. The current logical drive status is indicated in the cpqSasLogDrvStatus variable. User action: None required Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqSasHbaHwLocation * cpqSasLogDrvHbaIndex * cpqSasLogDrvIndex * cpqSasLogDrvStatus * cpqSasLogDrvOsName Supporting SNMP trap description: "Status is now [cpqLogPhyDrvStatus]." 5025 - cmasasd Log message: "SAS Tape Drive Status Changed: Status changed from [previous cpqSasTapeDrvStatus] to [current cpqSasTapeDrvStatus]." SNMP trap: cpqSas2TapeDrvStatusChange - 5025 in CPQSCSI.MIB Symptom: SAS Tape Drive Status Change. The agent has detected a change in the status of a SAS tape drive. The current tape drive status is indicated in the cpqSasTapeDrvStatus variable. User action: None required Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqSasHbaHwLocation * cpqSasTapeDrvLocationString * cpqSasTapeDrvHbaIndex * cpqSasTapeDrvIndex * cpqSasTapeDrvName * cpqSasTapeDrvFWRev * cpqSasTapeDrvSerialNumber * cpqSasTapeDrvSasAddress * cpqSasTapeDrvStatus Supporting SNMP trap description: "Status is now [cpqSasPhyDrvStatus]." 5026 - cmasasd Log message: "Solid State Disk Wear Status Change (5026). Solid State Disk Wear Status is now [cpqSasPhyDrvSSDWearStatus]" SNMP trap: cpqSasPhyDrvSSDWearStatusChange - 5026 in CPQSCSI.MIB Symptom: Solid State Disk Wear Status Change. The agent has detected a change in the SSD wear status of a SAS or SATA physical drive. The variable cpqSasPhyDrvSSDWearStatus indicates the current SSD wear status User action: If the SSD wear status is ssdWearOut(6), replace the drive. Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqSasHbaHwLocation * cpqSasPhyDrvLocationString * cpqSasPhyDrvHbaIndex * cpqSasPhyDrvIndex * cpqSasPhyDrvType * cpqSasPhyDrvModel * cpqSasPhyDrvFWRev * cpqSasPhyDrvSerialNumber * cpqSasPhyDrvSasAddress * cpqSasPhyDrvSSDWearStatus Supporting SNMP trap description: "Solid State Disk Wear Status Change (5026). Solid State Disk Wear Status is now [cpqSasPhyDrvSSDWearStatus]" Trap IDs: 8008-8032 8008 - cmascsid Log message: "Storage system fan status changed to [cpqSsBoxFanStatus string]." SNMP trap: cpqSs3FanStatusChange - 8008 in CPQSTSYS.MIB Symptom: Storage system fan status change. The agent has detected a change in the Fan Status of a storage system. The variable cpqSsBoxFanStatus indicates the current fan status. User action: If the fan status is degraded or failed, replace any failed fans. Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqSsBoxFanStatus Supporting SNMP trap description: "Storage System fan status changed to [cpqSsBoxFanStatus]." 8009 - cmascsid Log message: "Storage system temperature failure." SNMP trap: cpqSs3TempFailed - 8009 in CPQSTSYS.MIB Symptom: Storage system temperature failure. The agent has detected that a temperature status has been set to Failed. The storage system will be shut down. User action: Shut down the storage system as soon as possible. Ensure that the storage system environment is cooled properly and that no components are overheated. Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqSsBoxTempStatus Supporting SNMP trap description: "Storage System will be shut down." 8010 - cmascsid Log message: "Storage system temperature degraded." SNMP trap: cpqSs3TempDegraded - 8010 in CPQSTSYS.MIB Symptom: Storage system temperature degraded. The agent has detected a temperature status that has been set to degraded. The storage system's temperature is outside of the normal operating range. User action: Shut down the storage system as soon as possible. Ensure that the storage system environment is cooled properly and that no components are overheated. Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqSsBoxTempStatus Supporting SNMP trap description: "Temp is outside of normal range." 8011 - cmascsid Log message: "Storage system temperature OK." SNMP trap: cpqSs3TempOk - 8011 in CPQSTSYS.MIB Symptom: Storage system temperature ok. The temperature status has been set to OK. The storage system's temperature has returned to normal operating range. It can be reactivated by the administrator. User action: None Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqSsBoxTempStatus Supporting SNMP trap description: "Storage System temperature ok." 8012 - cmascsid Log message: "Storage system side panel is re-installed on unit." SNMP trap: cpqSs3SidePanelInPlace - 8012 in CPQSTSYS.MIB Symptom: Storage System side panel is in place. The side panel status has been set to in place. The storage system's side panel has returned to a properly installed state. User action: None. Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqSsBoxSidePanelStatus Supporting SNMP trap description: "Side panel is re-installed on unit." 8013 - cmascsid Log message: "Storage system side panel is removed from unit." SNMP trap: cpqSs3SidePanelRemoved - 8013 in CPQSTSYS.MIB Symptom: Storage system side panel is removed. The side panel status has been set to removed. The storage system's side panel is not in a properly installed state. This situation might result in improper cooling of the drives in the storage system because of airflow changes caused by the missing side panel. User action: Replace the storage system side panel. Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqSsBoxSidePanelStatus Supporting SNMP trap description: "Side panel is removed from unit." 8015 - cmascsid Log message: "A storage system power supply unit has become degraded." SNMP trap: cpqSs4PwrSupplyDegraded - 8015 in CPQSTSYS.MIB Symptom: A storage system power supply status has been set to degraded. User action: Take action to restore power or replace any failed storage system power supply. Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqSsBoxFltTolPwrSupplyStatus Supporting SNMP trap description: "A storage system power supply unit has become degraded" 8018 - cmafcad Log message: "Power Supply UPS Status Change. Chassis Name: [cpqSsChassisName], UPS Status: [cpqSsPowerSupplyUpsStatus string]." SNMP trap: cpqSsExPowerSupplyUpsStatusChange - 8018 in CPQSTSYS.MIB Symptom: Storage system power supply UPS status change. The agent has detected a change status of a UPS attached to a storage system power supply. The variable cpqSsPowerSupplyUpsStatus indicates the current status. User action: If the UPS status is powerFailed(4) or batteryLow(5), take action to restore power to the UPS. Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqSsChassisName * cpqSsChassisTime * cpqSsPowerSupplyBay * cpqSsPowerSupplyUpsStatus Supporting SNMP trap description: "Storage system power supply UPS status changed to [cpqSsPowerSupplyUpsStatus]." 8019 - cmafcad Log message: "Temperature Sensor Status Change. Chassis name: [cpqSsChassisName], Temperature sensor status: [cpqSsTempSensorStatus string]." SNMP trap: cpqSsExTempSensorStatusChange - 8019 in CPQSTSYS.MIB Symptom: Storage system temperature sensor status change. The agent has detected a change in the status of a storage system temperature sensor. The variable cpqSsTempSensorStatus indicates the current status. User action: If the temperature status is degraded or failed, shut down the storage system as soon as possible. Ensure that the storage system environment is being cooled properly and that no components are overheated. Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqSsChassisName * cpqSsChassisTime * cpqSsTempSensorLocation * cpqSsTempSensorStatus * cpqSsTempSensorCurrentValue Supporting SNMP trap description: "Storage system temperature sensor status changed to [cpqSsTempSensorStatus]." 8020 - cmafcad Log message: "Fan status change. Chassis Name: [cpqSsChassisName], Fan Status: [cpqSsFanModuleStatus]." SNMP trap: cpqSsEx2FanStatusChange - 8020 in CPQSTSYS.MIB Symptom: Storage system fan status change. The agent has detected a change in the fan module status of a storage system. The variable cpqSsFanModuleStatus indicates the current fan status. User action: If the fan status is degraded or failed, replace any failed fans. Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqSsChassisName * cpqSsChassisTime * cpqSsFanModuleLocation * cpqSsFanModuleStatus * cpqSsFanModuleSerialNumber * cpqSsFanModuleBoardRevision Supporting SNMP trap description: "Storage system fan status changed to [cpqSsFanModuleStatus]." 8021 - cmafcad Log message: "Power Supply Status Change. Chassis Name: [cpqSsChassisName], Power Supply Status: [cpqSsPowerSupplyStatus string]." SNMP trap: cpqSsEx2PowerSupplyStatusChange - 8021 in CPQSTSYS.MIB Symptom: Storage system power supply status change. The agent has detected a change in the power supply status of a storage system. The variable cpqSsPowerSupplyStatus indicates the current status. User action: If the power supply status is failed, take action to restore power or replace the failed power supply. Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqSsChassisName * cpqSsChassisTime * cpqSsPowerSupplyBay * cpqSsPowerSupplyStatus * cpqSsPowerSupplySerialNumber * cpqSsPowerSupplyBoardRevision * cpqSsPowerSupplyFirmwareRevision Supporting SNMP trap description: "Storage system power supply status changed to [cpqSsPowerSupplyStatus]." 8022 - cmafcad Log message: "Backplane Fan Status Change. Chassis Name: [cpqSsChassisName], Status: [cpqSsBackplaneFanStatus]." SNMP trap: cpqSsExBackplaneFanStatusChange - 8022 in CPQSTSYS.MIB Symptom: Storage system fan status change. The agent has detected a change in the fan status of a storage system. The variable cpqSsBackplaneFanStatus indicates the current fan status. User action: If the fan status is degraded or failed, replace any failed fans. Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqSsChassisName * cpqSsChassisTime * cpqSsBackplaneIndex * cpqSsBackplaneVendor * cpqSsBackplaneModel * cpqSsBackplaneSerialNumber * cpqSsBackplaneFanStatus Supporting SNMP trap description: "Storage system fan status changed to [cpqSsBackplaneFanStatus]." 8023 - cmafcad Log message: "Backplane Temp Status Change. Chassis Name: [cpqSsChassisName], Status: [cpqSsBackplaneTempStatus]." SNMP trap: cpqSsExBackplaneTempStatusChange - 8023 in CPQSTSYS.MIB Symptom: Storage system temperature status change. The agent has detected a change in the status of the temperature in a storage system. The variable cpqSsBackplaneTempStatus indicates the current status. User action: If the temperature status is degraded or failed, shut down the storage system as soon as possible. Ensure that the storage system environment is being cooled properly and that no components are overheated. Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqSsChassisName * cpqSsChassisTime * cpqSsBackplaneIndex * cpqSsBackplaneVendor * cpqSsBackplaneModel * cpqSsBackplaneSerialNumber * cpqSsBackplaneTempStatus Supporting SNMP trap description: "Storage system temperature status changed to [cpqSsBackplaneTempStatus]." 8024 - cmafcad Log message: "Backplane Power Status Change. Chassis Name: [cpqSsChassisName], Status: [cpqSsBackplaneFtpsStatus string]." SNMP trap: cpqSsExBackplanePowerSupplyStatusChange - 8024 in CPQSTSYS.MIB Symptom: Storage system power supply status change. The agent has detected a change in the power supply status of a storage system. The variable cpqSsBackplaneFtpsStatus indicates the current status. User action: If the power supply status is degraded, take action to restore power or replace the failed power supply. Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqSsChassisName * cpqSsChassisTime * cpqSsBackplaneIndex * cpqSsBackplaneVendor * cpqSsBackplaneModel * cpqSsBackplaneSerialNumber * cpqSsBackplaneFtpsStatus Supporting SNMP trap description: "Storage system power supply status changed to [cpqSsBackplaneFtpsStatus]." 8025 - cmafcad Log message: "Redundant Server Option Status Change. Storage system redundant server option status changed to [cpqSsChassisRsoStatus string]." SNMP trap: cpqSsExRecoveryServerStatusChange - 8025 in CPQSTSYS.MIB Symptom: Storage system recovery server option status change. The agent has detected a change in the recovery server option status of a storage system. The variable cpqSsChassisRsoStatus indicates the current status. User action: If the RSO status is noSecondary(6) or linkDown(7), ensure the secondary server is operational and all cables are connected properly. If the RSO status is secondaryRunningAuto(8) or secondaryRunningUser(9), examine the primary server for failed components. Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqSsChassisName * cpqSsChassisTime * cpqSsChassisRsoStatus * cpqSsChassisIndex Supporting SNMP trap description: "Storage system recovery server option status changed to [cpqSsChassisRsoStatus]." 8029 - cmasasd Log message: " Storage box fan status changed: Status changed from [Old cpqSsBoxFanStatus] to [new cpqSsBoxFanStatus]." SNMP trap: cpqSs6FanStatusChange " 8029 in cpqstsys.mib Symptom: Storage System fan status change. The agent has detected a change in the Fan Status of a storage system. The variable cpqSsBoxFanStatus indicates the current fan status. User action: If the fan status is degraded or failed, replace any failed fans. Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqSsBoxCntlrHwLocation * cpqSsBoxCntlrIndex * cpqSsBoxBusIndex * cpqSsBoxVendor * cpqSsBoxModel * cpqSsBoxSerialNumber * cpqSsBoxFanStatus * cpqSsBoxLocationString Supporting SNMP trap description: " Storage box fan status changed: Status changed from [Old cpqSsBoxFanStatus] to [new cpqSsBoxFanStatus]." 8030 - cmasasd Log message: "Storage box temperature status changed: Status changed from [old cpqSsBoxTempStatus] to [new cpqSsBoxTempStatus]" SNMP trap: cpqSs6TempStatusChange" 8030 in cpqstsys.mib Symptom: Storage System temperature status change. The agent has detected a change in the temperature status of a storage system. The variable cpqSsBoxTempStatus indicates the current temperature status. User action: If the temperature status is degraded or failed, shutdown the storage system as soon as possible. Insure that the storage system environment is being cooled properly and that no components are overheated. Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqSsBoxCntlrHwLocation * cpqSsBoxCntlrIndex * cpqSsBoxBusIndex * cpqSsBoxVendor * cpqSsBoxModel * cpqSsBoxSerialNumber * cpqSsBoxTempStatus * cpqSsBoxLocationString Supporting SNMP trap description: "Storage box temperature status changed: Status changed from [old cpqSsBoxTempStatus] to [new cpqSsBoxTempStatus]" 8031 - cmasasd Log message: "Storage box power supply status changed: Status changed from [old cpqSsBoxFltTolPwrSupplyStatus] to [new cpqSsBoxFltTolPwrSupplyStatus]" SNMP trap: cpqSs6PwrSupplyStatusChange - 8031 in cpqstsys.mib Symptom: Storage system power supply status change. The agent has detected a change in the power supply status of a storage system. The variable cpqSsBoxFltTolPwrSupplyStatus indicates the current power supply status. User action: If the power supply status is degraded, take action to restore power or replace the failed power supply. Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqSsBoxCntlrHwLocation * cpqSsBoxCntlrIndex * cpqSsBoxBusIndex * cpqSsBoxVendor * cpqSsBoxModel * cpqSsBoxSerialNumber * cpqSsBoxFltTolPwrSupplyStatus * cpqSsBoxLocationString Supporting SNMP trap description: "Storage box power supply status changed: Status changed from [old cpqSsBoxFltTolPwrSupplyStatus] to [new cpqSsBoxFltTolPwrSupplyStatus]" 8032 - cmasasd Log Message: "Storage box connection status Change: Status is now [cpqSsBoxConnectionStatus]" SNMP trap: cpqSsConnectionStatusChange 8032 in CPQSTSYS.MIB Symptom: Storage system connection status change.The agent has detected a change in the connection status of a storage system. The variable cpqSSboxConnectionStatus indicates the current connection status. User action: If the connection status is disconnected, take action to restore the connection between the HBA and the storage system. Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqSsBoxCntlrHwLocation * cpqSsBoxCntlrIndex * cpqSsBoxBusIndex * cpqSsBoxVendor * cpqSsBoxModel * cpqSsBoxSerialNumber * cpqSsBoxConnectionStatus * cpqSsBoxLocationString * cpqSsBoxTargetSasAddress * cpqSsBoxLocalManageIpAddress Supporting SNMP trap description:. Storage box connection status Change: Status is now [cpqSsBoxConnectionStatus]" Trap IDs: 14004-16028 14004 - cmaided Log message: "ATA Disk Status Changes: Disk number [cpqIdeAtaDiskNumber], Status is now [cpqIdeAtaDiskStatus]" SNMP trap: cpqIdeAtaDiskStatusChange - 14004 in CPQIDE.MIB Symptom: ATA Disk Status Change. The agent has detected a change in the status of an ATA disk drive. The variable cpqIdeAtaDiskStatus indicates the current disk drive status. User action: If the physical drive status is smartError(3) or failed(4), replace the drive. Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqIdeAtaDiskControllerIndex * cpqIdeAtaDiskIndex * cpqIdeAtaDiskModel * cpqIdeAtaDiskFwRev * cpqIdeAtaDiskSerialNumber * cpqIdeAtaDiskStatus * cpqIdeAtaDiskChannel * cpqIdeAtaDiskNumber Supporting SNMP trap description: "ATA Disk Status Changes: Disk number [cpqIdeAtaDiskNumber], Status is now [cpqIdeAtaDiskStatus]" 14005 - cmaided Log message: "IDE Logical Drive Status Changes: Slot [cpqIdeControllerSlot], Status is now [cpqIdeLogicalDriveStatus]" SNMP trap: cpqIdeLogicalDriveStatusChange - 14005 in CPQIDE.MIB Symptom: IDE Logical Drive Status Change. The agent has detected a change in the status of an IDE logical drive. The variable cpqIdeLogicalDriveStatus indicates the current logical drive status. User action: If the logical drive status is failed(5), examine the array for failed drives that need replacement. Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqIdeControllerModel * cpqIdeControllerSlot * cpqIdeLogicalDriveControllerIndex * cpqIdeLogicalDriveIndex * cpqIdeLogicalDriveStatus Supporting SNMP trap description: "IDE Logical Drive Status Changes: Slot [cpqIdeControllerSlot], Status is now [cpqIdeLogicalDriveStatus]" 14006 - cmaided Log message: "Solid State Disk Wear Status Change (14006). Solid State Disk Wear Status is now [cpqIdeAtaDiskSSDWearStatus]" SNMP trap: cpqIdeAtaDiskSSDWearStatusChange - 14006 in CPQIDE.MIB Symptom: IDE Solid State Disk Wear Status Change. The agent has detected a change in SSD wear status of a SATA physical drive. The variable cpqIdeAtaDiskSSDWearStatus indicates the current SSD wear status. User action: If the SSD wear status is ssdWearOut(6), replace the drive. Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqIdeAtaDiskControllerIndex * cpqIdeAtaDiskIndex * cpqIdeAtaDiskModel * cpqIdeAtaDiskFwRev * cpqIdeAtaDiskSerialNumber * cpqIdeAtaDiskSSDWearStatus * cpqIdeAtaDiskChannel * cpqIdeAtaDiskNumber Supporting SNMP trap description: "Solid State Disk Wear Status Change (14006). Solid State Disk Wear Status is now [cpqIdeAtaDiskSSDWearStatus]" 16002 - cmafcad Log message: "Spare drive status change. Chassis name: [cpqSsChassisName], Bus: [cpqFcaSpareBusNumber], Bay: [cpqFcaSpareBay]. Spare status is now [cpqFcaSpareStatus string]." SNMP trap: cpqFcaSpareStatusChange - 16002 in cpqfca.mib Symptom: External Array Spare Drive Status Change. The agent has detected a change in the status of an External Array spare drive. The variable indicates the current spare drive status. The variable cpqFcaSpareBusNumber indicates the SCSI bus number associated with this drive. User action: If the spare drive status is failed, replace the drive." Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqSsChassisName * cpqSsChassisTime * cpqFcaSpareBusNumber * cpqFcaSpareBay * cpqFcaSpareStatus Supporting SNMP trap description: "Spare Status is now [cpqFcaSpareStatus] on bus [cpqFcaSpareBusNumber]." 16008 - cmafcad Log message: "Status is now %d for tape controller %s." SNMP trap: cpqFcTapeCntlrStatusChange - 16008 in cpqfca.mib Symptom: This trap signifies that the agent has detected a change in the status of a Fiber Channel Tape Controller. The variable cpqFcTapeCntlrStatus indicates the current tape controller status. The variable cpqFcTapeCntlrWWN indicates the unique tape controller world wide name associated with this controller. User action: If the tape controller status is offline, access to the tape library and tapes has been lost. Check the tape library and all Fibre connections for problems. * sysName * cpqHoTrapFlags * cpqFcTapeCntlrWWN * cpqFcTapeCntlrStatus Supporting SNMP trap description: ""Status is now [cpqFcTapeCntlrStatus] for tape controller [cpqFcTapeCntlrWWN]" 16014 - cmafcad Log message: "Redundant controller is now active. Chassis name: [cpqSsChassisName], I/O slot: [cpqFcaCntlrBoxIoS lot]" SNMP trap: cpqFcaCntlrActive - 16014 in CPQFCA.MIB Symptom: Fibre Array Controller Active. The agent has detected that a backup array controller in a duplexed pair has switched over to the active role. The variable cpqFcaCntlrBoxIoSlot indicates the new active controller index. User action: Check the partner controller for problems. If this was the result of a user initiated switch over, no action is required. Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqSsChassisName * cpqSsChassisTime * cpqFcaCntlrBoxIoSlot Supporting SNMP trap description: "Controller in i/o slot [cpqFcaCntlrBoxIoSlot] is now active on chassis [cpqSsChassisName]." 16016 - cmafcad Log message: "Physical drive status change. Chassis name: [cpqSsChassisName], Bus: [cpqFcaPhyDrvBusNumber], Bay: [cpqFcaPhyDrvBay]. Status is now [cpqFcaPhyDrvStatus string]." SNMP trap: cpqFca2PhyDrvStatusChange - 16016 in CPQFCA.MIB Symptom: External Array Physical Drive Status Change. The agent has detected a change in the status of a physical drive. The variable cpqFcaPhyDrvStatus indicates the current physical drive status. User action: If the physical drive status is threshExceeded(4), predictiveFailure(5) or failed(6), replace the drive. Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqSsChassisName * cpqSsChassisTime * cpqFcaPhyDrvBusNumber * cpqFcaPhyDrvBay * cpqFcaPhyDrvStatus * cpqFcaPhyDrvModel * cpqFcaPhyDrvSerialNum * cpqFcaPhyDrvFWRev * cpqFcaPhyDrvFailureCode Supporting SNMP trap description: "Status is now [cpqFcaPhyDrvStatus] for a physical drive on bus [cpqFcaPhyDrvBusNumber], bay [cpqFcaPhyDrvBay]." 16017 - cmafcad Log message: "Accelerator Board status change. Chassis name: [cpqSsChassisName], I/O slot: [cpqFcaAccelBoxIoSlot]. Status is now [cpqFcaAccelStatus string]." SNMP trap: cpqFca2AccelStatusChange - 16017 in CPQFCA.MIB Symptom: External Array Accelerator Board Status Change. The agent has detected a change in the status of an Array Accelerator Cache Board. The current status is represented by the variable cpqFcaAccelStatus. User action: If the accelerator board status is permDisabled(5), you might need to replace the accelerator board. Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqSsChassisName * cpqSsChassisTime * cpqFcaAccelBoxIoSlot * cpqFcaAccelStatus * cpqFcaCntlrModel * cpqFcaAccelSerialNumber * cpqFcaAccelTotalMemory * cpqFcaAccelErrCode Supporting SNMP trap description: "Status is now [cpqFcaAccelStatus]." 16018 - cmafcad Log message: "Accelerator Board Bad Data. Chassis name: [cpqSsChassisName], I/O slot: [cpqSsChassisName]. Accelerator lost battery power. Data loss possible." SNMP trap: cpqFca2AccelBadDataTrap - 16018 in CPQFCA.MIB Symptom: External Array Accelerator Board Bad Data. The agent has detected an Array Accelerator Cache Board that has lost battery power. If data was being stored in the accelerator memory when the system lost power, the data has been lost. User action: Verify that no data has been lost. Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqSsChassisName * cpqSsChassisTime * cpqFcaAccelBoxIoSlot * cpqFcaCntlrModel * cpqFcaAccelSerialNumber * cpqFcaAccelTotalMemory Supporting SNMP trap description: "Accelerator lost battery power. Data Loss possible." 16019 - cmafcad Log message: "Accelerator Board Battery Failed. Chassis name: [cpqSsChassisName], I/O slot: [cpqFcaAccelBoxIoSlot]." SNMP trap: cpqFca2AccelBatteryFailed - 16019 in CPQFCA.MIB Symptom: External Array Accelerator Board Battery Failed. The agent has detected a battery failure associated with the Array Accelerator Cache Board. User action: Replace the Accelerator Cache Board. Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqSsChassisName * cpqSsChassisTime * cpqFcaAccelBoxIoSlot * cpqFcaCntlrModel * cpqFcaAccelSerialNumber * cpqFcaAccelTotalMemory Supporting SNMP trap description: "Battery status is failed." 16020 - cmafcad Log message: "Array Controller status change. Chassis name: [cpqSsChassisName], I/O slot: [cpqFcaCntlrBoxIoSlot]. Status is now [cpqFcaCntlrStatus string]." SNMP trap: cpqFca2CntlrStatusChange - 16020 in CPQFCA.MIB Symptom: External Array Controller Status Change. The agent has detected a change in the status of an External Array Controller. The variable cpqFcaCntlrStatus indicates the current controller status. User action: If the controller status is offline(4), access to the storage box has been lost. Check the storage box and all Fibre Channel connections for problems. Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqSsChassisName * cpqSsChassisTime * cpqFcaCntlrBoxIoSlot * cpqFcaCntlrStatus * cpqFcaCntlrModel * cpqFcaCntlrSerialNumber * cpqFcaAccelTotalMemory Supporting SNMP trap description: "Status is now [cpqFcaCntlrStatus]." 16022 - cmafcad Log message: "Logical drive status change. Chassis name: [cpqSsChassisName], Storage box: [cpqFcaLogDrvBoxIndex] . Status is now [cpqFcaLogDrvStatus string] for logical drive [cpqFcaLogDrvIndex]." SNMP trap: cpqExtArrayLogDrvStatusChange - 16022 in cpqfca.mib Symptom: External Array Logical Drive Status Change. The agent has detected a change in the status of an External Array logical drive. The variable cpqFcaLogDrvStatus indicates the current logical drive status. User action: If the logical drive status is failed, examine the array for failed drives that need replacement. Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqSsChassisName * cpqSsChassisTime * cpqFcaLogDrvBoxIndex * cpqFcaLogDrvIndex * cpqFcaLogDrvStatus * cpqFcaLogDrvOsName * cpqFcaLogDrvFaultTol * cpqFcaLogDrvSize Supporting SNMP trap description: "Status is now [cpqFcaLogDrvStatus]." 16023 - cmafcad Log message: "Tape Drive Status Change: Status is now [cpqFcTapeDriveStatus] for [cpqFcTapeDriveModel] on port [cpqFcTapeDriveScsi Bus] target [cpqFcTapeDriveScsiTarget]." SNMP trap: cpqExtTapeDriveStatusChange - 16023 in cpqfca.mib Symptom: External Tape Drive Status Change. The agent has detected a change in the status of an External Tape Drive. The variable cpqFcTapeDriveStatus indicates the current tape status. User action: If the tape is failed or offline, check the tape and all connections. Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqFcTapeDriveCntlrIndex * cpqFcTapeDriveScsiBus * cpqFcTapeDriveScsiTarget * cpqFcTapeDriveScsiLun * cpqFcTapeDriveModel * cpqFcTapeDriveFWRev * cpqFcTapeDriveSerialNumber * cpqFcTapeDriveLocation * cpqFcTapeDriveStatus Supporting SNMP trap description: "Status is now [cpqFcTapeDriveStatus] for a tape drive." 16024 - cmafcad Log message: "Tape Drive Cleaning Require. Cleaning is required for [cpqFcTapeDriveModel] on port [cpqFcTapeDriveScsi Bus] device [cpqFcTapeDriveScsiTarget]." SNMP trap: cpqExtTapeDriveCleaningRequired - 16024 in cpqfca.mib Symptom: External Tape Drive Cleaning Required. The agent has detected a tape drive that needs to have a cleaning tape inserted and run. This will cause the tape drive heads to be cleaned. User action: None required Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqFcTapeDriveCntlrIndex * cpqFcTapeDriveScsiBus * cpqFcTapeDriveScsiTarget * cpqFcTapeDriveScsiLun, * cpqFcTapeDriveModel * cpqFcTapeDriveFWRev * cpqFcTapeDriveSerialNumber * cpqFcTapeDriveLocation Supporting SNMP trap description: "Cleaning is needed for tape drive." 16025 - cmafcad Log message: "Cleaning tape on port [cpqFcTapeDriveScsiBus] device [cpqFcTapeDriveScsiTarget] needs replacing." SNMP trap: cpqExtTapeDriveCleanTapeReplace - 16025 in cpqfca.mib Symptom: External Tape Drive Cleaning Tape Needs Replacing. The agent has detected that an autoloader tape unit has a cleaning tape that has been fully used and needs to be replaced with a new cleaning tape. User action: None required Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqFcTapeDriveCntlrIndex * cpqFcTapeDriveScsiBus * cpqFcTapeDriveScsiTarget * cpqFcTapeDriveScsiLun * cpqFcTapeDriveModel * cpqFcTapeDriveFWRev * cpqFcTapeDriveSerialNumber * cpqFcTapeDriveLocation Supporting SNMP trap description: "Cleaning tape needs replacing" 16026 - cmafcad Log message: "Status is now %d for the tape library." SNMP trap: cpqExtTapeLibraryStatusChange - 16026 in cpqfca.mib Symptom: External Tape Library Status Change. This trap signifies that the agent has detected a change in the status of an External Tape library. The variable cpqFcTapeLibraryStatus indicates the current tape library status. User action: If the tape library is failed or offline, check the tape library front panel and all connections. Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqFcTapeLibraryCntlrIndex * cpqFcTapeLibraryScsiBus * cpqFcTapeLibraryScsiTarget * cpqFcTapeLibraryScsiLun * cpqFcTapeLibraryModel * cpqFcTapeLibraryFWRev * cpqFcTapeLibrarySerialNumber * cpqFcTapeLibraryLocation * cpqFcTapeLibraryStatus Supporting SNMP trap description: "Status is now [cpqFcTapeLibraryStatus] for the tape library." 16027 - cmafcad Log message: "The door is %d for tape library." SNMP trap: cpqExtTapeLibraryDoorStatusChange - 16027 in cpqfca.mib Symptom: External Tape Library Door Status Change. This trap signifies that the agent has detected a change in the door status of an External Tape library. The variable cpqFcTapeLibraryDoorStatus indicates the current tape library door status. User action: If the tape library door is open, close the tape library door. Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqFcTapeLibraryCntlrIndex * cpqFcTapeLibraryScsiBus * cpqFcTapeLibraryScsiTarget * cpqFcTapeLibraryScsiLun * cpqFcTapeLibraryModel * cpqFcTapeLibraryFWRev * cpqFcTapeLibrarySerialNumber * cpqFcTapeLibraryLocation * cpqFcTapeLibraryDoorStatus Supporting SNMP trap description: "The door is [cpqFcTapeLibraryStatus] for tape library." 16028 - cmafcad Log message: "Host controller status change: slot [cpqFcaHostCntlrSlot], status is now [current cpqFcaHostCntlrStatus]" SNMP trap: cpqFca3HostCntlrStatusChange- 16028 in cpqfca.mib Symptom: Fibre Channel Host Controller Status Change. The agent has detected a change in the status of a Fibre Channel Host Controller. The variable cpqFcaHostCntlrStatus indicates the current controller status. User action: If the controller status is failed, replace the controller. Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqFcaHostCntlrHwLocation * cpqFcaHostCntlrIndex * cpqFcaHostCntlrStatus * cpqFcaHostCntlrModel * cpqFcaHostCntlrSerialNumber * cpqFcaHostCntlrWorldWideName * cpqFcaHostCntlrWorldWidePortName Supporting SNMP trap description: "Host controller status change: slot [cpqFcaHostCntlrSlot], status is now [current cpqFcaHostCntlrStatus]." SERVER AGENTS Trap IDs: 1005-6049 1005 - cmastdeqd Log message: "CPU internal corrected errors have passed a set threshold." SNMP trap: cpqSeCpuThresholdPassed - 1005 in CPQSTDEQ.MIB Symptom: This trap is sent when an internal CPU error threshold has been passed on a particular CPU causing it to go degraded. This trap will be sent when cpqSeCpuThreshPassed transitions from false to true. Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqSeCpuSlot * cpqSeCpuSocketNumber * cpqSeCpuSpeed * cpqSeCpuExtSpeed * cpqSeCpuCacheSize Supporting SNMP trap description: "CPU internal corrected errors have passed a set threshold." 1008 - cmastdeqd Log message: "A USB storage device has been attached to the system." SNMP trap: cpqSeUSBStorageDeviceAttached - 1008 in CPQSTDEQ.MIB Symptom: This trap is sent when a USB storage device has been attached. * sysName * cpqHoTrapFlags * cpqSeUSBPortIndex * cpqSeUSBPortDeviceName Supporting SNMP trap description: "A USB storage device has been attached to the system." 1009 - cmastdeqd Log message: "A USB storage device has been removed from the system." SNMP trap: cpqSeUSBStorageDeviceRemoved - 1009 in CPQSTDEQ.MIB Symptom: This trap is sent when a attached USB storage device is removed. * sysName * cpqHoTrapFlags * cpqSeUSBPortIndex * cpqSeUSBPortDeviceName Supporting SNMP trap description: "A USB storage device has been removed from the system." 6016 - cmahealthd Log message: "The frequency of correctable memory errors is so high that correctable error detection/correction has been disabled." SNMP trap: cpqHe3CorrectableMemoryLogDisabled - 6016 in CPQHLTH.MIB Symptom: Correctable memory error tracking disabled. The frequency of errors is so high that the error tracking logic has been temporarily disabled. The cpqHeCorrMemLogStatus variable indicates the current tracking status. Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqHeCorrMemLogStatus Supporting SNMP trap description: "Too many memory errors - tracking now disabled." 6017 - cmahealthd Log message: "The system will be shutdown due to a thermal condition." SNMP trap: cpqHe3ThermalTempFailed - 6017 in CPQHLTH.MIB Symptom: The temperature status has been set to Failed. The system will be shut down because of this thermal condition. Supporting SNMP trap data: * sysName * cpqHoTrapFlags Supporting SNMP trap description: "System will be shut down due to this thermal condition." 6018 - cmahealthd Log message: "The server's temperature is outside of normal operating range. The system will be shutdown." SNMP trap: cpqHe3ThermalTempDegraded - 6018 in CPQHLTH.MIB Symptom: The temperature status has been set to Degraded. The server's temperature is outside of the normal operating range. The server will be shut down if the cpqHeThermalDegradedAction variable is set to shutdown (3). Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqHeThermalDegradedAction Supporting SNMP trap description: "Temperature out of range. Shutdown may occur." 6019 - cmahealthd Log message: "The server's temperature has returned to normal operating range." SNMP trap: cpqHe3ThermalTempOk - 6019 in CPQHLTH.MIB Symptom: The temperature status has been set to OK. The server's temperature has returned to the normal operating range. Supporting SNMP trap data: * sysName * cpqHoTrapFlags Supporting SNMP trap description: "Temperature has returned to normal range." 6020 - cmahealthd Log message: "A required system fan is not operating normally." When the Thermal Degraded action is in Shutdown mode then concaninate below massages with above Log message. "The system will be shutdown." SNMP trap: cpqHe3ThermalSystemFanFailed - 6020 in CPQHLTH.MIB Symptom: The system fan status has been set to Failed. A required system fan is not operating normally. The system will be shutdown if the cpqHeThermalDegradedAction variable is set to shutdown (3). Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqHeThermalDegradedAction Supporting SNMP trap description: "Required fan not operating normally. Shutdown may occur." 6021 - cmahealthd Log message: "A system fan is not operating normally." When redundant Fan is removed or Failed system won't go for shutdown because, the minimal fan's are available for operating the system. SNMP trap: cpqHe3ThermalSystemFanDegraded - 6021 in CPQHLTH.MIB Symptom: The system fan status has been set to Degraded. An optional system fan is not operating normally. Supporting SNMP trap data: * sysName * cpqHoTrapFlags Supporting SNMP trap description: "An optional fan is not operating normally." 6022 - cmahealthd Log message: "A non-operational system fan has returned to normal operation." SNMP trap: cpqHe3ThermalSystemFanOk " 6022 - CPQHLTH.MIB Log message: "System fan has returned to normal operation." Supporting SNMP trap data: * sysName * cpqHoTrapFlags Supporting SNMP trap description: "System fan has returned to normal operation." 6023 - cmahealthd Log message: "A processor fan is not operating normally. The system will be shutdown." SNMP trap: cpqHe3ThermalCpuFanFailed - 6023 in CPQHLTH.MIB Symptom: The CPU fan status has been set to Failed. A processor fan is not operating normally. The server will be shut down. Supporting SNMP trap data: * sysName * cpqHoTrapFlags Supporting SNMP trap description: "CPU fan has failed. Server will be shutdown." 6024 - cmahealthd Log message: "A non-operational processor fan has returned to normal operation." SNMP trap: cpqHe3ThermalCpuFanOk - 6024 in CPQHLTH.MIB Symptom: The CPU fan status has been set to OK. Any previously non-operational processor fans have returned to normal operation. Supporting SNMP trap data: * sysName * cpqHoTrapFlags Supporting SNMP trap description: "CPU fan is now OK." 6025 - cmahealthd Log message: "An 'ASR Recover Complete' trap signifies that the system has been shutdown by the ASR feature and has just become operational again." SNMP trap: cpqHe3AsrConfirmation - 6025 in CPQHLTH.MIB Symptom: The server is operational again. The server was previously shut down by the Automatic Server Recovery (ASR) feature and has become operational again. Supporting SNMP trap data: * sysName * cpqHoTrapFlags Supporting SNMP trap description: "Server is operational again after ASR shutdown." 6026 - cmahealthd Log message: "The server has previously been shutdown due to a thermal anomaly and has just become operational again." SNMP trap: cpqHe3ThermalConfirmation - 6026 in CPQHLTH.MIB Symptom: The server is operational again. The server was previously shut down because of a thermal anomaly on the server and has become operational again. Supporting SNMP trap data: * sysName * cpqHoTrapFlags Supporting SNMP trap description: "Server is operational again after thermal shutdown." 6027 - cmahealthd Log message: "Power on Self-Test (POST) errors occurred during the server restart process." SNMP trap: cpqHe3PostError - 6027 in CPQHLTH.MIB Symptom: One or more power on self-test (POST) errors occurred. POST errors occur during the server restart process. Supporting SNMP trap data: * sysName * cpqHoTrapFlags Supporting SNMP trap description: "Errors occurred during server restart." 6028 - cmahealthd Log message: "The server power supply status has become degraded." SNMP trap: cpqHe3FltTolPwrSupplyDegraded - 6028 in CPQHLTH.MIB Symptom: The fault tolerant power supply sub-system condition has been set to Degraded. Supporting SNMP trap data: * sysName * cpqHoTrapFlags Supporting SNMP trap description: "The server power supply status has become degraded." 6029 " cmahealthd Log message: "A correctable memory log entry indicates a memory module needs to be replaced." SNMP trap: cpqHe3CorrMemReplaceMemModule - 6029 in CPQHLTH.MIB Symptom: A correctable memory log entry indicates a memory module needs to be replaced. The errors have been corrected, but the memory module should be replaced. The error information is reported in the variable cpqHeCorrMemErrDesc. Supporting SNMP trap data: * sysName * cpqHoTrapFlags Supporting SNMP trap description: "Correctable memory errors require a replacement memory module." 6032 - cmahealthd Log message: "The power supply has lost redundancy." SNMP trap: cpqHe3FltTolPowerRedundancyLost - 6032 in CPQHLTH.MIB Symptom: The fault tolerant power supplies have lost redundancy for the specified chassis. Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqHeFltTolPowerSupplyChassis Supporting SNMP trap description: "The Power Supplies are no longer redundant on Chassis [cpqHeFltTolPowerSupplyChassis]." 6033 - cmahealthd Log message: "The power supply was inserted." SNMP trap: cpqHe3FltTolPowerSupplyInserted - 6033 in CPQHLTH.MIB Symptom: A fault tolerant power supply has been inserted in the specified chassis and bay location. Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqHeFltTolPowerSupplyChassis * cpqHeFltTolPowerSupplyBay Supporting SNMP trap description: "The Power Supply Inserted on Chassis [cpqHeFltTolPowerSupplyChassis], Bay [cpqHeFltTolPowerSupplyBay]." 6034 - cmahealthd Log message: "The power supply was removed." SNMP trap: cpqHe3FltTolPowerSupplyRemoved - 6034 in CPQHLTH.MIB Symptom: A fault tolerant power supply has been removed from the specified chassis and bay location. Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqHeFltTolPowerSupplyChassis * cpqHeFltTolPowerSupplyBay Supporting SNMP trap description: "The Power Supply Removed on Chassis [cpqHeFltTolPowerSupplyChassis], Bay [cpqHeFltTolPowerSupplyBay]." 6035 - cmahealthd Log message: "The redundant fan has degraded." SNMP trap: cpqHe3FltTolFanDegraded - 6035 in CPQHLTH.MIB Symptom: The fault tolerant fan condition has been set to Degraded for the specified chassis and fan. Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqHeFltTolFanChassis * cpqHeFltTolFanIndex Supporting SNMP trap description: "The Fan Degraded on Chassis [cpqHeFltTolFanChassis], Fan [cpqHeFltTolFanIndex]." 6036 - cmahealthd Log message: "The redundant fan has failed." SNMP trap: cpqHe3FltTolFanFailed - 6036 in CPQHLTH.MIB Symptom: The fault tolerant fan condition has been set to Failed for the specified chassis and fan. Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqHeFltTolFanChassis * cpqHeFltTolFanIndex Supporting SNMP trap description: "The Fan Failed on Chassis [cpqHeFltTolFanChassis], Fan [cpqHeFltTolFanIndex]." 6037 - cmahealthd Log message: "The redundant fan has lost redundancy." SNMP trap: cpqHe3FltTolFanRedundancyLost - 6037 in CPQHLTH.MIB Symptom: The fault tolerant fans have lost redundancy for the specified chassis. Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqHeFltTolFanChassis Supporting SNMP trap description: "The Fans are no longer redundant on Chassis [cpqHeFltTolFanChassis]." 6038 - cmahealthd Log message: "The redundant fan was inserted." SNMP trap: cpqHe3FltTolFanInserted - 6038 in CPQHLTH.MIB Symptom: A fault tolerant fan has been inserted into the specified chassis and fan location. Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqHeFltTolFanChassis * cpqHeFltTolFanIndex Supporting SNMP trap description: "The Fan Inserted on Chassis [cpqHeFltTolFanChassis], Fan [cpqHeFltTolFanIndex]." 6039 - cmahealthd Log message: "The redundant fan was removed." SNMP trap: cpqHe3FltTolFanRemoved - 6039 in CPQHLTH.MIB Symptom: A fault tolerant fan has been removed from the specified chassis and fan location. Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqHeFltTolFanChassis * cpqHeFltTolFanIndex Supporting SNMP trap description: "The Fan Removed on Chassis [cpqHeFltTolFanChassis], Fan [cpqHeFltTolFanIndex]." 6040 - cmahealthd Log message: "The temperature status has failed." SNMP trap: cpqHe3TemperatureFailed - 6040 in CPQHLTH.MIB Symptom: The temperature status has been set to Failed in the specified chassis and location. The system will be shut down because of this condition. Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqHeTemperatureChassis * cpqHeTemperatureLocale Supporting SNMP trap description: "Temperature Exceeded on Chassis [cpqHeTemperatureChassis], Location [cpqHeTemperatureLocale]." 6041 - cmahealthd Log message: "The temperature status is degraded." SNMP trap: cpqHe3TemperatureDegraded - 6041 in CPQHLTH.MIB Symptom: The temperature status has been set to Degraded in the specified chassis and location. The server's temperature is outside of the normal operating range. The server will be shut down if the cpqHeThermalDegradedAction variable is set to shutdown(3). Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqHeThermalDegradedAction * cpqHeTemperatureChassis * cpqHeTemperatureLocale Supporting SNMP trap description: "Temperature out of range on Chassis [cpqHeTemperatureChassis], Location [cpqHeTemperatureLocale]. Shutdown may occur." 6042 - cmahealthd Log message: "The temperature status is ok." SNMP trap: cpqHe3TemperatureOk - 6042 in CPQHLTH.MIB Symptom: The temperature status has been set to OK in the specified chassis and location. The server's temperature has returned to the normal operating range. Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqHeTemperatureChassis * cpqHeTemperatureLocale Supporting SNMP trap description: "Temperature Normal on Chassis [cpqHeTemperatureChassis], Location [cpqHeTemperatureLocale]." 6043 - cmahealthd Log message: "The DC-DC Power Converter condition has been set to Degraded." SNMP trap: cpqHe3PowerConverterDegraded - 6043 in CPQHLTH.MIB Symptom: The DC-DC Power Converter condition has been set to Degraded for the specified chassis, slot, and socket. Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqHePwrConvChassis * cpqHePwrConvSlot * cpqHePwrConvSocket Supporting SNMP trap description: "The Power Converter Degraded on Chassis [cpqHePwrConvChassis], Slot [cpqHePwrConvSlot], Socket [cpqHePwrConvSocket]." 6044 - cmahealthd Log message: "The DC-DC Power Converter condition has been set to Failed." SNMP trap: cpqHe3PowerConverterFailed - 6044 in CPQHLTH.MIB Symptom: The DC-DC Power Converter condition has been set to Failed for the specified chassis, slot, and socket. Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqHePwrConvChassis * cpqHePwrConvSlot * cpqHePwrConvSocket Supporting SNMP trap description: "The Power Converter Failed on Chassis [cpqHePwrConvChassis], Slot [cpqHePwrConvSlot], Socket [cpqHePwrConvSocket]." 6045 - cmahealthd Log message: "The DC-DC Power Converters have lost redundancy." SNMP trap: cpqHe3PowerConverterRedundancyLost - 6045 in CPQHLTH.MIB Symptom: The DC-DC Power Converters have lost redundancy for the specified chassis. Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqHePwrConvChassis Supporting SNMP trap description: "The Power Converters are no longer redundant on Chassis [cpqHePwrConvChassis] ." 6046 - cmahealthd Log message: "Cache accelerator parity error occurred. A cache module needs to be replaced." SNMP trap: cpqHe3CacheAccelParityError - 6046 in CPQHLTH.MIB Symptom: A cache accelerator parity error indicates a cache module needs to be replaced. The error information is reported in the variable cpqHeEventLogErrorDesc. Supporting SNMP trap data: * sysName * cpqHoTrapFlags Supporting SNMP trap description: "Cache Accelerator errors may require a replacement module." 6047 - cmahealthd Log message: "Online Spare Memory Engaged" SNMP trap: cpqHeResilientMemOnlineSpareEngaged - 6047 in CPQHLTH.MIB Symptom: Advanced Memory Protection Online Spare Engaged. The Advanced Memory Protection subsystem has detected a memory fault. The Online Spare Memory has been activated. User action: Schedule server down time to replace the faulty memory. Supporting SNMP trap data: * sysName * cpqHoTrapFlags Supporting SNMP trap description: "The Advanced Memory Protection subsystem has engaged the online spare memory." 6048 - cmahealthd Log message: "The power supply is OK." SNMP trap: cpqHe4FltTolPowerSupplyOk - 6048 in CPQHLTH.MIB Symptom: The fault tolerant power supply condition has been set back to the OK state for the specified chassis and bay location. Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqHeFltTolPowerSupplyChassis * cpqHeFltTolPowerSupplyBay * cpqHeFltTolPowerSupplyStatus * cpqHeFltTolPowerSupplyModel * cpqHeFltTolPowerSupplySerialNumber * cpqHeFltTolPowerSupplyAutoRev * cpqHeFltTolPowerSupplyFirmwareRev * cpqHeFltTolPowerSupplySparePartNum * cpqSiServerSystemId Supporting SNMP trap description: "The Power Supply is OK on Chassis [cpqHeFltTolPowerSupplyChassis], Bay [cpqHeFltTolPowerSupplyBay], Status [cpqHeFltTolPowerSupplyStatus], Model [cpqHeFltTolPowerSupplyModel], Serial Num [cpqHeFltTolPowerSupplySerialNumber], Firmware [cpqHeFltTolPowerSupplyFirmwareRev]." 6049 - cmahealthd Log message: "The power supply has degraded." SNMP trap: cpqHe4FltTolPowerSupplyDegraded - 6049 in CPQHLTH.MIB Symptom: The fault tolerant power supply condition has been set to Degraded for the specified chassis and bay location. Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqHeFltTolPowerSupplyChassis * cpqHeFltTolPowerSupplyBay * cpqHeFltTolPowerSupplyStatus * cpqHeFltTolPowerSupplyModel * cpqHeFltTolPowerSupplySerialNumber * cpqHeFltTolPowerSupplyAutoRev * cpqHeFltTolPowerSupplyFirmwareRev * cpqHeFltTolPowerSupplySparePartNum * cpqSiServerSystemId Supporting SNMP trap description: "The Power Supply is Degraded on Chassis [cpqHeFltTolPowerSupplyChassis], Bay [cpqHeFltTolPowerSupplyBay], Status [cpqHeFltTolPowerSupplyStatus], Model [cpqHeFltTolPowerSupplyModel], Serial Num [cpqHeFltTolPowerSupplySerialNumber], Firmware [cpqHeFltTolPowerSupplyFirmwareRev]." Trap IDs: 6050-9016 6050 - cmahealthd Log message: "The power supply has failed." SNMP trap: cpqHe4FltTolPowerSupplyFailed - 6050 in CPQHLTH.MIB Symptom: The fault tolerant power supply condition has been set to Failed for the specified chassis and bay location. Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqHeFltTolPowerSupplyChassis * cpqHeFltTolPowerSupplyBay * cpqHeFltTolPowerSupplyStatus * cpqHeFltTolPowerSupplyModel * cpqHeFltTolPowerSupplySerialNumber * cpqHeFltTolPowerSupplyAutoRev * cpqHeFltTolPowerSupplyFirmwareRev * cpqHeFltTolPowerSupplySparePartNum * cpqSiServerSystemId Supporting SNMP trap description: "The Power Supply is Failed on Chassis [cpqHeFltTolPowerSupplyChassis], Bay [cpqHeFltTolPowerSupplyBay], Status [cpqHeFltTolPowerSupplyStatus], Model [cpqHeFltTolPowerSupplyModel], Serial Num [cpqHeFltTolPowerSupplySerialNumber], Firmware [cpqHeFltTolPowerSupplyFirmwareRev]." 6051 - cmahealthd Log message: "Mirrored Memory Engaged" SNMP trap: cpqHeResilientMemMirroredMemoryEngaged - 6051 in CPQHLTH.MIB Symptom: Advanced Memory Protection Mirrored Memory Engaged. The Advanced Memory Protection subsystem has detected a memory fault. Mirrored Memory has been activated. User action: Replace the faulty memory. Supporting SNMP trap data: * sysName * cpqHoTrapFlags Supporting SNMP trap description: "The Advanced Memory Protection subsystem has engaged the online spare memory." 6052 - cmahealthd Log message: "Advanced ECC Memory Engaged" SNMP trap: cpqHeResilientAdvancedECCMemoryEngaged - 6052 in CPQHLTH.MIB Symptom: Advanced Memory Protection Advanced ECC Memory Engaged. The Advanced Memory Protection subsystem has detected a memory fault. Advanced ECC has been activated. User action: Replace the faulty memory. Supporting SNMP trap data: * sysName * cpqHoTrapFlags Supporting SNMP trap description: "The Advanced Memory Protection subsystem has engaged the advanced ECC memory." 6053 - cmahealthd Log message: "Advanced XOR Memory Engaged" SNMP trap: cpqHeResilientMemXorMemoryEngaged - 6053 in CPQHLTH.MIB Symptom: Advanced Memory Protection XOR Engine Memory Engaged. The Advanced Memory Protection subsystem detected a memory fault. The XOR engine has been activated. User action: Replace the faulty memory. Supporting SNMP trap data: * sysName * cpqHoTrapFlags Supporting SNMP trap description: "The Advanced Memory Protection subsystem has engaged the XOR memory." 6054 - cmahealthd Log message: "The Power Supplies are now redundant on Chassis %d." SNMP trap: cpqHe3FltTolPowerRedundancyRestore - 6054 in CPQHLTH.MIB Symptom: The fault tolerant power supplies have returned to a redundant state for the specified chassis. User action: None required Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqHeFltTol PowerSupplyChassis Supporting SNMP trap description: "The Power Supplies are now redundant on Chassis [cpqHeFltTolPowerSupplyChassis]." 6055 - cmahealthd Log message: "The Fans are now redundant on Chassis %d." SNMP trap: cpqHe3FltTolFanRedundancyRestored - 6055 in CPQHLTH.MIB Symptom: The Fault Tolerant Fans have returned to a redundant state for the specified chassis. User action: None required Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqHeFltTolFanChassis Supporting SNMP trap description: "The Fans are now redundant on Chassis [cpqHeFltTolFanChassis]." 6057 - cmahealthd Log message: "Memory Board or Cartridge Removed" SNMP trap: cpqHeResMemBoardRemoved - 6057 in CPQHLTH.MIB Symptom: Memory board or cartridge removed. An Advanced Memory Protection sub-system board or cartridge was removed from the system. User action: Ensure the board or cartridge has memory correctly installed and reinsert the memory board or cartridge back into the system. Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqHeResMemBoardSlotIndex Supporting SNMP trap description: "Memory Board or Cartridge Removed from Slot [cpqHeResMemBoardSlotIndex]." 6058 - cmahealthd Log message: "Memory Board or Cartridge Inserted" SNMP trap: cpqHeResMemBoardInserted - 6058 in CPQHLTH.MIB Symptom: Memory board or cartridge inserted. An Advanced Memory Protection sub-system board or cartridge has been inserted into the system. User action: None required Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqHeResMemBoardSlotIndex Supporting SNMP trap description: "Memory Board or Cartridge Inserted into Slot [cpqHeResMemBoardSlotIndex]." 6064 - cmahealthd Log message: "Correctable \\ Uncorrectable Memory Errors Detected." SNMP trap: cpqHe5CorrMemReplaceMemModule - 6064 in CPQHLTH.MIB Symptom: Corrected Memory Errors Detected. The errors have been corrected, but the memory module should be replaced. Value 0 for CPU means memory is not Processor based. User action: None required Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqHeResMem2BoardNum * cpqHeResMem2CpuNum * cpqHeResMem2RiserNum * cpqHeResMem2ModuleNum * cpqHeResMem2ModulePartNo * cpqHeResMem2ModuleSize * cpqSiServerSystemId Supporting SNMP trap description: "Correctable memory errors require a replacement of the memory module in slot [cpqHeResMem2BoardNum], cpu [cpqHeResMem2CpuNum], riser [cpqHeResMem2RiserNum], socket [cpqHeResMem2ModuleNum]." 6065 - cmahealthd Log message: "Memory Board or Cartridge or riser Removed from Slot %d, Cpu %d Riser %d." SNMP trap: cpqHe5ResMemBoardRemoved - 6055 in CPQHLTH.MIB Symptom:" Memory board or cartridge or riser removed." An Advanced Memory Protection sub-system board or cartridge or riser has been removed from the system. Value 0 for CPU means memory is not processor based. User action: Insure the board or cartridge or riser has memory correctly installed and re-insert the memory board or cartridge or CPU back into the system. Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqHeResMem2BoardSlotNum * cpqHeResMem2BoardCpuNum * cpqHeResMem2BoardRiserNum Supporting SNMP trap description: "Memory Board or Cartridge or riser Removed from Slot [cpqHeResMem2BoardSlotNum] , Cpu [cpqHeResMem2BoardCpuNum] Riser [cpqHeResMem2BoardRiserNum]." 6066 - cmahealthd Log message: "Memory Board or Cartridge Inserted into Slot %d, Cpu %d, Riser %d." SNMP trap: cpqHe5ResMemBoardInserted - 6066 in CPQHLTH.MIB Symptom: Memory board or cartridge or riser inserted. An Advanced Memory Protection sub-system board or cartridge or riser has been inserted into the system. Value 0 for CPU means memory is not processor based. User action: None required Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqHeResMem2BoardSlotNum * cpqHeResMem2BoardCpuNum * cpqHeResMem2BoardRiserNum Supporting SNMP trap description: "Memory Board or Cartridge inserted into Slot [cpqHeResMem2BoardSlotNum], Cpu [cpqHeResMem2BoardCpuNum] Riser [cpqHeResMem2BoardRiserNum]." 6067 - cmahealthd Log message: "Memory Board or Cartridge Bus Error Detected in Slot %d, Cpu %d, Riser %d." SNMP trap: cpqHe5ResMemBoardBusError - 6067 in CPQHLTH.MIB Symptom: "Memory board or cartridge or Riser bus error detected." An Advanced Memory Protection sub-system board or cartridge or Riser bus error has been detected. Value 0 for CPU means memory is not processor based. User action: Replace the indicated board or cartridge or Riser. Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqHeResMem2BoardSlotNum * cpqHeResMem2BoardCpuNum * cpqHeResMem2BoardRiserNum Supporting SNMP trap description:" "Memory Board or Cartridge Bus Error Detected in Slot[cpqHeResMem2BoardSlotNum], Cpu[cpqHeResMem2BoardCpuNum], Riser[cpqHeResMem2BoardRiserNum]." 6068 - cmahealthd Log message: "The Advanced Memory Protection subsystem has engaged the LockStep memory." SNMP trap: cpqHeResilientMemLockStepMemoryEngaged - 6068 in CPQHLTH.MIB Symptom: Advanced Memory Protection LockStep Engine Memory Engaged." The Advanced Memory Protection subsystem has detected a memory fault. The LockStep engine has been activated. User action: Replace the faulty memory. Supporting SNMP trap data: * sysName * cpqHoTrapFlags Supporting SNMP trap description: "The Advanced Memory Protection subsystem has engaged the LockStep memory." 6069 - cmahealthd Log message: "The fault tolerant power supply AC power loss for the specified chassis and bay location." SNMP trap: cpqHe4FltTolPowerSupplyACpowerloss - 6069 in CPQHLTH.MIB Symptom: The fault tolerant power supply in the specified chassis and bay reported AC power loss. User action: Check the power connection to the power supply. Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqHeFltTolPowerSupplyChassis * cpqHeFltTolPowerSupplyBay * cpqHeFltTolPowerSupplyStatus * cpqHeFltTolPowerSupplyModel * cpqHeFltTolPowerSupplySerialNumber * cpqHeFltTolPowerSupplyAutoRev * cpqHeFltTolPowerSupplyFirmwareRev * cpqHeFltTolPowerSupplySparePartNum * cpqSiServerSystemId Supporting SNMP trap description: "The Power Supply AC power loss in [cpqHeFltTolPowerSupplyChassis], Bay [cpqHeFltTolPowerSupplyBay], Status [cpqHeFltTolPowerSupplyStatus], Model [cpqHeFltTolPowerSupplyModel], Serial Num [cpqHeFltTolPowerSupplySerialNumber], Firmware [cpqHeFltTolPowerSupplyFirmwareRev]." 9003 - cmasm2d Log message: "The Remote Insight firmware has detected unauthorized login attempts" SNMP trap: cpqSm2UnauthorizedLoginAttempts - 9003 in CPQSM2.MIB Symptom: Remote Insight/Integrated Lights-Out Unauthorized Login Attempts. The Remote Insight/Integrated Lights-Out firmware has detected unauthorized login attempts. Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqSm2CntlrBadLoginAttemptsThresh Supporting SNMP trap description: "More than [cpqSm2CntlrBadLoginAttemptsThresh] unauthorized login attempts detected." 9004 - cmasm2d Log message: "The Remote Insight Battery has failed and needs to be replaced" SNMP trap: cpqSm2BatteryFailed - 9004 in CPQSM2.MIB Symptom: Remote Insight Battery Failed. The Remote Insight battery has failed and needs to be replaced. Supporting SNMP trap data: * sysName * cpqHoTrapFlags Supporting SNMP trap description: "Remote Insight battery failed." 9005 - cmasm2d Log message: "The Remote Insight firmware has detected a board self test error" SNMP trap: cpqSm2SelfTestError - 9005 in CPQSM2.MIB Symptom: Remote Insight/Integrated Lights-Out Self Test Error. The Remote Insight/Integrated Lights-Out firmware has detected a Remote Insight self test error. Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqSm2CntlrSelfTestErrors Supporting SNMP trap description: "Remote Insight/Integrated Lights-Out self test error [cpqSm2CntlrSelfTestErrors]." 9006 - cmasm2d Log message: "The firmware is not responding" SNMP trap: cpqSm2InterfaceError - 9006 in CPQSM2.MIB Symptom: Remote Insight/Integrated Lights-Out Interface Error. The host OS has detected an error in the Remote Insight/ Integrated Lights-Out interface. The firmware is not responding. Supporting SNMP trap data: * sysName * cpqHoTrapFlags Supporting SNMP trap description: "Server [sysName], Remote Insight/Integrated Lights-Out interface error." 9007 - cmasm2d Log message: "The Remote Insight battery has been disconnected" SNMP trap: cpqSm2BatteryDisconnected - 9007 in CPQSM2.MIB Symptom: Remote Insight Battery Disconnected. The Remote Insight battery cable was disconnected. Supporting SNMP trap data: * sysName * cpqHoTrapFlags Supporting SNMP trap description: "Remote Insight battery disconnected." 9008 - cmasm2d Log message: "The Remote Insight keyboard cable has been disconnected" SNMP trap: cpqSm2KeyboardCableDisconnected - 9008 in CPQSM2.MIB Symptom: Keyboard Cable Disconnected. The Remote Insight keyboard cable was disconnected. Supporting SNMP trap data: * sysName * cpqHoTrapFlags Supporting SNMP trap description: "Remote Insight keyboard cable disconnected." 9009 - cmasm2d Log message: "The Remote Insight mouse cable has been disconnected" SNMP trap: cpqSm2MouseCableDisconnected - 9009 in CPQSM2.MIB Symptom: Mouse Cable Disconnected. The Remote Insight mouse cable was disconnected. Supporting SNMP trap data: * sysName * cpqHoTrapFlags Supporting SNMP trap description: "Remote Insight mouse cable disconnected." 9010 - cmasm2d Log message: "The Remote Insight external power cable has been disconnected" SNMP trap: cpqSm2ExternalPowerCableDisconnected - 9010 in CPQSM2.MIB Symptom: External Power Cable Disconnected. The Remote Insight external power cable was disconnected. Supporting SNMP trap data: * sysName * cpqHoTrapFlags Supporting SNMP trap description: "Remote Insight external power cable disconnected." 9015 - cmasm2d Log message: "The iLO NIC Link is Down." SNMP trap: cpqSm2NicLinkDown - 9015 in CPQSM2.MIB Symptom: "The Remote Insight/ Integrated Lights-Out firmware has detected the loss of network link." Supporting SNMP trap data: * sysName Supporting SNMP trap description:"The iLO NIC Link is Down." 9016 - cmasm2d Log message: "The iLO NIC Link is Up." SNMP trap: cpqSm2NicLinkDown - 9016 in CPQSM2.MIB Symptom: "The Remote Insight/ Integrated Lights-Out firmware has detected the presence of network link." Supporting SNMP trap data: * sysName Supporting SNMP trap description:"The iLO NIC Link is Up" Trap IDs: 22001-22036 22001 - cmarackd Log message: "The Rack Name has changed" SNMP trap: cpqRackNameChanged - 22001 in CPQRACK.MIB Symptom: Rack name has changed. An agent or utility has changed the name of the rack. Each of the server blades in each of the enclosures within the rack will be updated to reflect the new rack name. It might take several minutes for the rack name change to be propagated throughout the entire rack. User action: None Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqRackName * cpqRackUid * cpqRackSerialNum * cpqRackTrapSequenceNum Supporting SNMP trap description: "The rack name has changed to [cpqRackName]." 22002 - cmarackd Log message: "The Enclosure Name has changed" SNMP trap: cpqRackEnclosureNameChanged - 22002 in CPQRACK.MIB Symptom: The enclosure name has changed. An agent or utility has changed the name of an enclosure within the rack. Each of the components within the rack will be updated to reflect the new enclosure name. It might take several minutes for the enclosure name change to be propagated throughout the entire enclosure. User action: None Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqRackName * cpqRackUid * cpqRackCommonEnclosureName * cpqRackCommonEnclosureSerialNum * cpqRackCommonEnclosureModel * cpqRackCommonEnclosureSparePartNumber * cpqRackCommonEnclosu reTrapSequenceNum Supporting SNMP trap description: "The enclosure name has changed to [cpqRackCommonEnclosureName] in rack [cpqRackName] ." 22003 - cmarackd Log message: "Enclosure removed" SNMP trap: cpqRackEnclosureRemoved - 22003 in CPQRACK.MIB Symptom: The enclosure has been removed. An enclosure has been removed from the rack. User action: None Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqRackName * cpqRackUid * cpqRackCommonEnclosureName * cpqRackCommonEnclosureModel * cpqRackCommonEnclosureSerialNum * cpqRackCommonEnclosureSparePartNumber * cpqRackCommonEnclosu reTrapSequenceNu m Supporting SNMP trap description: "The enclosure [cpqRackCommonEnclosureName] has been removed from rack [cpqRackName]." 22004 - cmarackd Log message: "Enclosure inserted" SNMP trap: cpqRackEnclosureInserted - 22004 in CPQRACK.MIB Symptom: The enclosure has been inserted. An enclosure has been inserted into the rack. User action: None Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqRackName * cpqRackUid * cpqRackCommonEnclosureName * cpqRackCommonEnclosureModel * cpqRackCommonEnclosureSerialNum * cpqRackCommonEnclosureSparePartNumber * cpqRackCommonEnclosu reTrapSequenceNu m Supporting SNMP trap description: "The enclosure [cpqRackCommonEnclosureName] has been inserted into rack [cpqRackName]." 22013 - cmarackd Log message: "Rack power supply failed" SNMP trap: cpqRackPowerSupplyFailed - 22013 in CPQRACK.MIB Symptom: The power supply status has been set to Failed. A power supply has failed. User action: Replace the power supply as soon as possible. Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqRackName * cpqRackUid * cpqRackPowerSupplyEnclosureName * cpqRackPowerSupplySerialNum * cpqRackPowerSupplyPosition * cpqRackPowerSupplyFWRev * cpqRackPowerSupplySparePartNumber * cpqRackCommonEnclosureSerialNum * cpqRackCommonEnclosureTrapSequenceNum Supporting SNMP trap description: "The power supply [cpqRackPowerSupplyPosition] in enclosure [cpqRackPowerSupplyEnclosureName] in rack [cpqRackName] has been set to Failed." 22016 - cmahealthd Log message: "Rack power supply removed" SNMP trap: cpqRackPowerSupplyRemoved - 22016 in CPQRACK.MIB Symptom: The power supply has been removed. User action: None required Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqRackName * cpqRackUid * cpqRackPowerSupplyEnclosureName * cpqRackPowerSupplySerialNum * cpqRackPowerSupplyPosition * cpqRackPowerSupplyFWRev * cpqRackPowerSupplySparePartNumber * cpqRackCommonEnclosureSerialNum * cpqRackCommonEnclosureTrapSequenceNum Supporting SNMP trap description: "The power supply [cpqRackPowerSupplyPosition] in enclosure [cpqRackPowerSupplyEnclosureName] in rack [cpqRackName] has been removed." 22017 - cmahealthd Log message: "Rack power supply inserted" SNMP trap: cpqRackPowerSupplyInserted - 22017 in CPQRACK.MIB Symptom: The power supply has been inserted. User action: None required Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqRackName * cpqRackUid * cpqRackPowerSupplyEnclosureName * cpqRackPowerSupplySerialNum * cpqRackPowerSupplyPosition * cpqRackPowerSupplyFWRev * cpqRackPowerSupplySparePartNumber * cpqRackCommonEnclosureSerialNum * cpqRackCommonEnclosureTrapSequenceNum Supporting SNMP trap description: "The power supply [cpqRackPowerSupplyPosition] in enclosure [cpqRackPowerSupplyEnclosureName] in rack [cpqRackName] has been inserted." 22018 - cmahealthd Log message: "Rack power supply not redundant" SNMP trap: cpqRackPowerSubsystemNotRedundant - 22018 in CPQRACK.MIB Symptom: The rack power subsystem is no longer in a redundant state. User action: Replace any failed power supplies as soon as possible to return the system to a redundant state. Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqRackName * cpqRackUid * cpqRackPowerEnclosureName * cpqRackCommonEnclosureSerialNum * cpqRackCommonEnclosureTrapSequenceNum Supporting SNMP trap description: "The power subsystem in enclosure [cpqRackPowerEnclosureName] in rack [cpqRackName] is no longer redundant." 22019 - cmahealthd Log message: "Rack power supply detected an input voltage problem." SNMP trap: cpqRackPowerSubsystemLineVoltageProblem - 22019 in CPQRACK.MIB Symptom: The rack power supply detected an input line voltage problem. User action: Check the power input for the power supply or replace any failed power supplies as soon as possible. Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqRackName * cpqRackUid * cpqRackPowerSupplyEnclosureName * cpqRackPowerSupplyPosition * cpqRackPowerSupplyFWRev * cpqRackPowerSupplyInputLineStatus * cpqRackPowerSupplySparePartNumber * cpqRackCommonEnclosureSerialNum * cpqRackCommonEnclosureTrapSequenceNum Supporting SNMP trap description: "The rack power supply detected an input line voltage problem in power supply [cpqRackPowerSupplyPosition], enclosure [cpqRackPowerSupplyEnclosureName], rack [cpqRackName]." 22020 - cmahealthd Log message: "Rack power subsystem overload condition" SNMP trap: cpqRackPowerSubsystemOverloadCondition - 22020 in CPQRACK.MIB Symptom: The rack power subsystem has an overload condition. User action: Replace any failed power supplies as soon as possible to return the system to a redundant state. Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqRackName * cpqRackUid * cpqRackPowerEnclosureName * cpqRackCommonEnclosureSparePartNumber * cpqRackCommonEnclosureSerialNum * cpqRackCommonEnclosureTrapSequenceNu m Supporting SNMP trap description: "The power subsystem in enclosure [cpqRackPowerEnclosureName] in rack [cpqRackName] is in an overload condition." 22022 - cmahealthd Log message: "Server power on prevented to preserve redundancy." SNMP trap: cpqRackServerPowerOnFailedNotRedundant - 22022 in CPQRACK.MIB Symptom: Server power on prevented to preserve redundancy. There is not enough power to power on the server blade and maintain redundancy for the other blades in the enclosure. User action: Check power connections or add power supplies. Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqRackName * cpqRackUid * cpqRackServerBladeEnclosureName * cpqRackServerBladePosition * cpqRackServerBladeSparePartNumber * cpqRackCommonEnclosureSerialNum * cpqRackCommonEnclosureTrapSequenceNum Supporting SNMP trap description: "Server power on prevented to preserve redundancy in blade [cpqRackServerBladePosition], in enclosure [cpqRackServerBladeEnclosureName], in rack [cpqRackName]." 22023 - cmahealthd Log message: "Server power on prevented inadequate power to power on." SNMP trap: cpqRackServerPowerOnFailedNotEnoughPower - 22023 in CPQRACK.MIB Symptom: Inadequate power to power on. There is not enough power to power on the server blade. User action: Check power connections or add power supplies. Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqRackName * cpqRackUid * cpqRackServerBladeEnclosureName * cpqRackServerBladePosition * cpqRackServerBladeSparePartNumber * cpqRackCommonEnclosureSerialNum * cpqRackCommonEnclosureTrapSequenceNum Supporting SNMP trap description: "Inadequate power to power on blade [cpqRackServerBladePosition], in enclosure [cpqRackServerBladeEnclosureName], in rack [cpqRackName]." 22024 - cmahealthd Log message: "Server power on prevented server enclosure micro-controller not found." SNMP trap: cpqRackServerPowerOnFailedEnclosureNotFound - 22024 in CPQRACK.MIB Symptom: Inadequate power to power on. There is not enough power to power on the server blade. The server enclosure micro-controller was not found. User action: Check server enclosure connections or add power supplies. Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqRackName * cpqRackUid * cpqRackServerBladeEnclosureName * cpqRackServerBladePosition * cpqRackServerBladeSparePartNumber * cpqRackCommonEnclosureSerialNum * cpqRackCommonEnclosureTrapSequenceNum Supporting SNMP trap description: "Inadequate power to power on blade [cpqRackServerBladePosition], in enclosure [cpqRackServerBladeEnclosureName], in rack [cpqRackName]." 22025 - cmahealthd Log message: "Server power on prevented power enclosure micro-controller not found." SNMP trap: cpqRackServerPowerOnFailedPowerChassisNotFound - 22025 in CPQRACK.MIB Symptom: Inadequate power to power on. There is not enough power to power on the server blade. The power enclosure micro-controller was not found. User action: Check power enclosure connections or add power supplies. Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqRackName * cpqRackUid * cpqRackServerBladeEnclosureName * cpqRackServerBladePosition * cpqRackServerBladeSparePartNumber * cpqRackCommonEnclosureSerialNum * cpqRackCommonEnclosureTrapSequenceNum Supporting SNMP trap description: "Inadequate power to power on blade [cpqRackServerBladePosition], in enclosure [cpqRackServerBladeEnclosureName], in rack [cpqRackName]." 22026 - cmahealthd Log message: "Server power on via manual override." SNMP trap: cpqRackServerPowerOnManualOverride - 22026 in CPQRACK.MIB Symptom: Server power on via manual override. The server blade was powered on by a manual override. User action: None Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqRackName * cpqRackUid * cpqRackServerBladeEnclosureName * cpqRackServerBladePosition * cpqRackServerBladeSparePartNumber * cpqRackCommonEnclosureSerialNum * cpqRackCommonEnclosureTrapSequenceNum Supporting SNMP trap description: "Server power on via manual override on blade [cpqRackServerBladePosition], in enclosure [cpqRackServerBladeEnclosureName], in rack [cpqRackName]." 22027 - cmahealthd Log message: "Rack enclosure fuse open." SNMP trap: cpqRackFuseOpen - 22027 in CPQRACK.MIB Symptom: Fuse open. The fuse has been tripped. User action: Check enclosure and/or blade power connections and reset the fuse. Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqRackName * cpqRackUid * cpqRackCommonEnclosureName * cpqRackCommonEnclosu reFuseLocation * cpqRackCommonEnclosureSparePartNumber * cpqRackCommonEnclosureSerialNum * cpqRackCommonEnclosureTrapSequenceNum Supporting SNMP trap description: "Fuse open fuse [cpqRackCommonEnclosureFuseLocation], in enclosure [cpqRackCommonEnclosureName], in rack [cpqRackName]." 22028 - cmahealthd Log message: "Server blade removed" SNMP trap: cpqRackServerBladeRemoved - 22028 in CPQRACK.MIB Symptom: Server blade removed. The server blade has been removed from the enclosure. User action: None Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqRackName * cpqRackUid * cpqRackServerBladeEnclosureName * cpqRackServerBladeName * cpqRackServerBladePosition * cpqRackServerBladeSparePartNumber * cpqRackCommonEnclosureSerialNum * cpqRackCommonEnclosureTrapSequenceNum Supporting SNMP trap description: "Server blade [cpqRackServerBladeName] removed from position [cpqRackServerBladePosition], in enclosure [cpqRackServerBladeEnclosureName], in rack [cpqRackName]." 22029 - cmahealthd Log message: "Server blade inserted" SNMP trap: cpqRackServerBladeInserted - 22029 in CPQRACK.MIB Symptom: Server blade inserted. The server blade has been inserted into the enclosure. User action: None Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqRackName * cpqRackUid * cpqRackServerBladeEnclosureName * cpqRackServerBladeName * cpqRackServerBladePosition * cpqRackServerBladeSparePartNumber * cpqRackCommonEnclosureSerialNum * cpqRackCommonEnclosureTrapSequenceNum Supporting SNMP trap description: "Server blade [cpqRackServerBladeName] inserted into position [cpqRackServerBladePosition], in enclosure [cpqRackServerBladeEnclosureName], in rack [cpqRackName]." 22030 - cmahealthd Log message: "Power subsystem not load balanced." SNMP trap: cpqRackPowerChassisNotLoadBalanced - 22030 in CPQRACK.MIB Symptom: Power subsystem not load balanced. The power subsystem is out of balance for this power enclosure. User action: Check the power enclosure and power supplies. Replace any failed or degraded power supplies. Add additional power supplies if needed. Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqRackName * cpqRackUid * cpqRackCommonEnclosureName * cpqRackCommonEnclosureSerialNum * cpqRackCommonEnclosureSparePartNumber * cpqRackCommonEnclosureTrapSequenceNum Supporting SNMP trap description: "Power subsystem not load balanced in enclosure [cpqRackCommonEnclosureName], in rack [cpqRackName]." 22031 - cmahealthd Log message: "Power subsystem DC power problem." SNMP trap: cpqRackPowerChassisDcPowerProblem - 22031 in CPQRACK.MIB Symptom: Power subsystem DC power problem. There is a power subsystem DC power problem for this power enclosure. User action: Check the power enclosure and power supplies. Replace any failed or degraded power supplies. Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqRackName * cpqRackUid * cpqRackCommonEnclosureName * cpqRackCommonEnclosureSerialNum * cpqRackCommonEnclosureSparePartNumber * cpqRackCommonEnclosureTrapSequenceNum Supporting SNMP trap description: "Power subsystem DC power problem in enclosure [cpqRackCommonEnclosureName], in rack [cpqRackName]." 22032 - cmahealthd Log message: "Power subsystem AC facility input power exceeded." SNMP trap: cpqRackPowerChassisAcFacilityPowerExceeded - 22032 in CPQRACK.MIB Symptom: Power subsystem AC facility input power exceeded for this power enclosure. User action: Check the power enclosure and power supplies. Replace any failed or degraded power supplies. Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqRackName * cpqRackUid * cpqRackCommonEnclosureName * cpqRackCommonEnclosureSerialNum * cpqRackCommonEnclosureSparePartNumber * cpqRackCommonEnclosureTrapSequenceNum Supporting SNMP trap description: "Power subsystem AC facility input power exceeded in enclosure [cpqRackCommonEnclosureName], in rack [cpqRackName]." 22033 - cmahealthd Log message: "Unknown power consumption" SNMP trap: cpqRackPowerUnknownPowerConsumption - 22033 in CPQRACK.MIB Symptom: Unknown power consumption. There is an unknown power consumer drawing power. User action: Check the power enclosure and power supplies. Replace any failed or degraded power supplies. Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqRackName * cpqRackUid * cpqRackCommonEnclosureSerialNum * cpqRackCommonEnclosu reTrapSequenceNu m Supporting SNMP trap description: "Unknown power consumption in rack [cpqRackName]." 22034 - cmahealthd Log message: "Power subsystem load balancing wire missing" SNMP trap: cpqRackPowerChassisLoadBalancingWireMissing - 22034 in CPQRACK.MIB Symptom: Power subsystem load balancing wire missing. The power subsystem load balancing wire is missing. User action: Connect the load balancing wire. Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqRackName * cpqRackUid * cpqRackCommonEnclosureName * cpqRackCommonEnclosureSerialNum * cpqRackCommonEnclosureSparePartNumber * cpqRackCommonEnclosureTrapSequenceNum Supporting SNMP trap description: "Power subsystem load balancing wire missing for enclosure [cpqRackCommonEnclosureName], in rack [cpqRackName]." 22035 - cmahealthd Log message: "Power subsystem has too many power enclosures." SNMP trap: cpqRackPowerChassisTooManyPowerChassis - 22035 in CPQRACK.MIB Symptom: Power subsystem has too many power enclosures. The maximum number of power enclosures was exceeded. User action: Remove the extra power enclosure. Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqRackName * cpqRackUid * cpqRackCommonEnclosureName * cpqRackCommonEnclosureSerialNum * cpqRackCommonEnclosureTrapSequenceNum Supporting SNMP trap description: "Power subsystem has too may power enclosures [cpqRackCommonEnclosureName], in rack [cpqRackName]." 22036 - cmahealthd Log message: "Power subsystem has been improperly configured." SNMP trap: cpqRackPowerChassisConfigError - 22036 in CPQRACK.MIB Symptom: Power subsystem improperly configured. The power subsystem was improperly configured. User action: Check the cabling of the power enclosure. Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqRackName * cpqRackUid * cpqRackCommonEnclosureName * cpqRackCommonEnclosureSerialNum * cpqRackCommonEnclosureSparePartNumber * cpqRackCommonEnclosureTrapSequenceNum Supporting SNMP trap description: "Power subsystem has been improperly configured in enclosure [cpqRackCommonEnclosureName], in rack [cpqRackName]." NIC AGENTS Trap IDs: 18001-18014 18001 - cmanicd Log message: "Connectivity is restored for adapter in slot %d, port %d" SNMP trap: cpqNicConnectivityRestored - 18001 in CPQNIC.MIB Symptom: This trap is sent any time connectivity is restored to a logical adapter. This occurs when the physical adapter in a single adapter configuration returns to the OK condition or at least one physical adapter in a logical adapter group returns to the OK condition. This can be caused by replacement of a faulty cable or re-attaching a cable that was unplugged. User action: None required Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqNicIfPhysAdapterSlot * cpqNicIfPhysAdapterPort Supporting SNMP trap description: "Connectivity is restored for adapter in slot [cpqNicIfPhysAdapterSlot], port [cpqNicIfPhysAdapterPort]." 18002 - cmanicd Log message: "Connectivity lost for adapter in slot %d, port %d" SNMP trap: cpqNicConnectivityLost - 18002 in CPQNIC.MIB Symptom: This trap is sent any time the status of a logical adapter changes to the Failed condition. This occurs when the adapter in a single adapter configuration fails, or when the last adapter in a redundant configuration fails. This can be caused by loss of link because of a cable being removed from the adapter or the hub or switch. Internal adapter, hub, or switch failures can also cause this condition. User action: Check the cables to the adapter and the hub or switch. If no cable problems are found, the adapter, hub, or switch may need replacement. Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqNicIfPhysAdapterSlot * cpqNicIfPhysAdapterPort Supporting SNMP trap description: "Connectivity lost for adapter in slot [cpqNicIfPhysAdapterSlot], port [cpqNicIfPhysAdapterPort]." 18005 - cmanicd Log message: "Connectivity is restored for adapter in slot %d, port %d." SNMP trap: cpqNic2ConnectivityRestored " 18005 in CPQNIC.MIB Symptom: This trap is sent any time connectivity is restored to a logical adapter. This occurs when the physical adapter in a single adapter configuration returns to the OK condition or at least one physical adapter in a logical adapter group returns to the OK condition. This can be caused by replacement of a faulty cable or re-attaching a cable that was unplugged. User action: None required Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqNicIfPhysAdapterSlot * cpqNicIfPhysAdapterPort * cpqSiServerSystemId * cpqNicIfPhysAdapterStatus * cpqSePciSlotBoardName * cpqNicIfPhysAdapterPartNumber * ipAdEntAddr Supporting SNMP trap description: "Connectivity is restored for adapter in slot [cpqNicIfPhysAdapterSlot], port [cpqNicIfPhysAdapterPort]." 18006 - cmanicd Log message: "Connectivity lost for adapter in slot %d, port %d." SNMP trap: cpqNic2ConnectivityLost " 18006 in CPQNIC.MIB Symptom: This trap is sent any time the status of a logical adapter changes to the Failed condition. This occurs when the adapter in a single adapter configuration fails, or when the last adapter in a redundant configuration fails. This can be caused by loss of link because of a cable being removed from the adapter or the hub or switch. Internal adapter, hub, or switch failures can also cause this condition. User action: Check the cables to the adapter and the hub or switch. If no cable problems are found, the adapter, hub, or switch may need replacement. Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqNicIfPhysAdapterSlot * cpqNicIfPhysAdapterPort * cpqSiServerSystemId * cpqNicIfPhysAdapterStatus * cpqSePciSlotBoardName * cpqNicIfPhysAdapterPartNumber * ipAdEntAddr Supporting SNMP trap description: "Connectivity lost for adapter in slot [cpqNicIfPhysAdapterSlot], port [cpqNicIfPhysAdapterPort]." 18007 - cmanicd Log message: "Redundancy increased by adapter in slot %d, port %d." SNMP trap: cpqNic2RedundancyIncreased " 18007 in CPQNIC.MIB Symptom: This trap is sent any time a previously failed physical in a connected logical adapter group returns to the OK condition. This trap is not sent when a logical adapter group has connectivity restored from a Failed condition. The cpqNicConnectivityRestored trap is sent instead. This can be caused by replacement of a faulty cable or re-attaching a cable that was unplugged. User action: None required Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqNicIfPhysAdapterSlot * cpqNicIfPhysAdapterPort * cpqSiServerSystemId * cpqNicIfPhysAdapterStatus * cpqSePciSlotBoardName * cpqNicIfPhysAdapterPartNumber * ipAdEntAddr * cpqNicIfLogMapAdapterOKCoun Supporting SNMP trap description: "Redundancy increased by adapter in slot [cpqNicIfPhysAdapterSlot], port [cpqNicIfPhysAdapterPort]." 18008 - cmanicd Log message: "Redundancy decreased by adapter in slot %d, port %d." SNMP trap: cpqNic2RedundancyReduced " 18008 in CPQNIC.MIB Symptom: This trap is sent any time a physical adapter in a logical adapter group changes to the Failed condition, but at least one physical adapter remains in the OK condition. This can be caused by loss of link because of a cable being removed from the adapter or the hub or switch. Internal adapter, hub, or switch failures can also cause this condition. User action: Check the cables to the adapter and the hub or switch. If no cable problems are found, the adapter, hub, or switch might need replacement. Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqNicIfPhysAdapterSlot * cpqNicIfPhysAdapterPort * cpqSiServerSystemId * cpqNicIfPhysAdapterStatus * cpqSePciSlotBoardName * cpqNicIfPhysAdapterPartNumber * ipAdEntAddr * cpqNicIfLogMapAdapterOKCount Supporting SNMP trap description: "Redundancy decreased by adapter in slot [cpqNicIfPhysAdapterSlot], port [cpqNicIfPhysAdapterPort]." 18009 - cmanicd Log message: "Virus-like activity detected" SNMP trap: cpqNicVirusLikeActivityDetected " 18009 in CPQNIC.MIB Symptom: This trap is sent when the Virus Throttle Filter Driver detects virus like activity. User action: The system reporting this trap requires immediate attention. Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqSiServerSystemId Supporting SNMP trap description: "Virus-like activity detected" 18010 - cmanicd Log message: "Virus-like activity no longer detected" SNMP trap: cpqNicVirusLikeActivityStopped " 18010 in CPQNIC.MIB Symptom: This trap is sent when the Virus Throttle Filter Driver no longer detects virus like activity. User action: None required Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqSiServerSystemId Supporting SNMP trap description: "Virus-like activity no longer detected" 18011 - cmanicd Log message: "Connectivity is restored for adapter in slot %d, port %d." SNMP Trap: cpqNic3ConnectivityRestored " 18011 in CPQNIC.MIB Symptom: This trap will be sent any time connectivity is restored to a logical adapter. This occurs when the physical adapter in a single adapter configuration returns to the OK condition or at least one physical adapter in a logical adapter group returns to the OK condition. This can be caused by replacement of a faulty cable or re-attaching a cable that was unplugged. User action: None required Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqNicIfPhysAdapterSlot * cpqNicIfPhysAdapterPort * cpqSiServerSystemId * cpqNicIfPhysAdapterStatus * cpqSePciSlotBoardName * cpqNicIfPhysAdapterPartNumber * ipAdEntAddr * cpqNicIfLogMapIPV6Address Supporting SNMP trap description: "Connectivity is restored for adapter in slot [cpqNicIfPhysAdapterSlot], port [cpqNicIfPhysAdapterPort]." 18012 - cmanicd Log message: "Connectivity Lost for adapter in slot %d, port %d." SNMP Trap: cpqNic3ConnectivityLost " 18012 in CPQNIC.MIB Symptom: This trap will be sent any time the status of a logical adapter changes to the Failed condition. This occurs when the adapter in a single adapter configuration fails, or when the last adapter in a redundant configuration fails. This can be caused by loss of link due to a cable being removed from the adapter or the Hub or Switch. Internal adapter, Hub, or Switch failures can also cause this condition. User action: Check the cables to the adapter and the Hub or Switch. If no cable problems are found, the adapter, Hub, or Switch may need replacement. Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqNicIfPhysAdapterSlot * cpqNicIfPhysAdapterPort * cpqSiServerSystemId * cpqNicIfPhysAdapterStatus * cpqSePciSlotBoardName * cpqNicIfPhysAdapterPartNumber * ipAdEntAddr * cpqNicIfLogMapIPV6Address Supporting SNMP trap description: "Connectivity lost for adapter in slot [cpqNicIfPhysAdapterSlot], port [cpqNicIfPhysAdapterPort]." 18013 - cmanicd Log message: "Redundancy increased by adapter in slot %d, port %d." SNMP Trap: cpqNic3RedundancyIncreased " 18013 in CPQNIC.MIB Symptom: This trap will be sent any time a previously failed physical adapter in a connected logical adapter group returns to the OK condition. This trap is not sent when a logical adapter group has connectivity restored from a Failed condition. The cpqNicConnectivityRestored trap is sent instead. This can be caused by replacement of a faulty cable or re-attaching a cable that was unplugged. User action: None required. Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqNicIfPhysAdapterSlot * cpqNicIfPhysAdapterPort * cpqSiServerSystemId * cpqNicIfPhysAdapterStatus * cpqSePciSlotBoardName * cpqNicIfPhysAdapterPartNumber * ipAdEntAddr * cpqNicIfLogMapIPV6Address * cpqNicIfLogMapAdapterOKCount Supporting SNMP trap description: " Redundancy increased by adapter in slot [cpqNicIfPhysAdapterSlot], port [cpqNicIfPhysAdapterPort]." 18014 - cmanicd Log message: "Redundancy Reduced by adapter in slot %d, port %d." SNMP Trap: cpqNic3RedundancyReduced " 18014 in CPQNIC.MIB Symptom: This trap will be sent any time a physical adapter in a logical adapter group changes to the Failed condition, but at least one physical adapter remains in the OK condition. This can be caused by loss of link due to a cable being removed from the adapter or the Hub or Switch. Internal adapter, Hub, or Switch failures can also cause this condition. User action: Check the cables to the adapter and the Hub or Switch. If no cable problems are found, the adapter, Hub, or Switch may need replacement. Supporting SNMP trap data: * sysName * cpqHoTrapFlags * cpqNicIfPhysAdapterSlot * cpqNicIfPhysAdapterPort * cpqSiServerSystemId * cpqNicIfPhysAdapterStatus * cpqSePciSlotBoardName * cpqNicIfPhysAdapterPartNumber * ipAdEntAddr * cpqNicIfLogMapIPV6Address * cpqNicIfLogMapAdapterOKCount Supporting SNMP trap description: "Redundancy decreased by adapter in slot [cpqNicIfPhysAdapterSlot], port [cpqNicIfPhysAdapterPort]."