HP Smart Storage Administrator Diagnostics and SmartSSD Wear Gauge Utility CLI Version 2.10-14.0 (linuxX64) 12/16/2014 Description ----------- The HP Smart Storage Administrator Diagnostics and SmartSSD Wear Gauge Utility CLI (HPSSADUCLI) is a command line application that creates a report of all HP storage controllers and disk drives. This report provides vital information to HP service personnel to assist in identifying faults or conditions that may require attention. The utility can also generate SmartSSD Wear Gauge reports. These reports contain wear (usage) information for all SmartSSD devices attached to the system. * All other product names mentioned herein may be trademarks of their respective companies. Support ------- Supported Operating Systems 32bit Platforms: Red Hat Enterprise Linux 5 Red Hat Enterprise Linux 6 SuSE Linux Enterprise Server 10, 11 64bit Platforms: SuSE Linux Enterprise Server 11 (x86_64) Red Hat Enterprise Linux 5 (x86_64) Red Hat Enterprise Linux 6 (x86_64) * All these platforms need to have the following driver upgrades: CISS driver version 2.4.50 or later Updated versions of the driver are available from http://www.hp.com. Supported Controllers --------------------- Dynamic Smart Array B110i SATA RAID Smart Array P212 Controller Smart Array P410 Controller Smart Array P410i Controller Smart Array P411 Controller Smart Array P711m Controller Smart Array P712m Controller Smart Array P812 Controller Dynamic Smart Array B120i Dynamic Smart Array B320i Smart Array P220i Controller Smart Array P222 Controller Smart Array P420 Controller Smart Array P420i Controller Smart Array P421 Controller Smart Array P721m Controller Smart Array P822 Controller Smart Array P230i Controller Smart Array P430 Controller Smart Array P431 Controller Smart Array P530 Controller Smart Array P531 Controller Smart Array P731m Controller Smart Array P830 Controller Smart Array P830i Controller Dynamic Smart Array B140i Smart HBA H240 Controller Smart HBA H240ar Controller Smart HBA H241 Controller Smart HBA H244br Controller Smart Array P244br Controller Smart Array P246br Controller Smart Array P440 Controller Smart Array P440ar Controller Smart Array P441 Controller Smart Array P741m Controller Smart Array P840 Controller Smart Array P841 Controller Installing & Running the HP Smart Storage Administrator -------------------------------------------------------------- Installation: HPSSACLI is distributed using Red Hat Package Manager (RPM) packages and .deb packages for Debian. If there is an older version of HPSSACLI installed on the system, please use "rpm -e hpssacli" to remove it first. Use "rpm -i " to install the application. Please type "man rpm" for other details regarding RPM. NOTE: On Debian systems, a ".deb" package file can be installed using the "dpkg -i hpssacli.xxx.deb" command. The dpkg -r hpssacli command is used to remove the package. The software resides in /opt/hp/hpssacli and the executable name is hpssacli which is located in /usr/sbin. When attempting to run HPSSACLI on any HP-supported version of Linux, it is highly recommended that you install the latest version of the HP ProLiant Smart Array Controller driver for your intended Linux operating system. Drivers may be obtained by clicking on "Support & Drivers" from HP's website at: http://www.hp.com For Debian 64 bit: dpkg -i --force-architecture . hpssacli requires the libunwind bit package to be installed. Run the HPSSACLI: Dynamic Smart Array B110i Dynamic Smart Array B120i Dynamic Smart Array B320i Dynamic Smart Array B140i Running HPSSADUCLI ------------------------------------------------------------------------ To run the command-line application: Open a command prompt and change directory (cd) to the location where HPSSADUCLI is installed. This is commonly /opt/hp/hpssaducli/bin. To generate a diagnostic report, enter the following command: hpssaducli -f adu-report.zip To generate a SmartSSD Wear gauge report, enter the following command: hpssaducli -ssd -f ssd-report.zip More options can be found by "hpssaducli -help". Additional Notes ---------------- Both the diagnostic and SmartSSD wear gauge reports are generated in compressed (ZIP) format. The diagnostic report output archive contains the following files: * ADUReport.txt => Diagnostic report in text format * ADUReport.xml => Diagnostic report in XML format * ADUReport.htm => HTML viewer for diagnostic report * report.checksum => checksum file * SlotX.txt (SlotX.old) => Controller serial output log Note: The serial output log file(s) are only available if the "HP Storage Agent" daemon is installed and running. To view the diagnostic report in a browser, extract the ADUReport.htm. Open ADUReport.htm in the browser. The SmartSSD wear gauge report output archive contains the following files: * SmartSSDWearGaugeReport.txt => SmartSSD wear gauge report in text format * SmartSSDWearGaugeReport.json => SmartSSD wear gauge report in JSON format * SmartSSDWearGaugeReport.htm => HTML viewer for the JSON wear gauge report To view the SmartSSD wear gauge report in a browser, extract the SmartSSDWearGaugeReport.json, SmartSSDWearGaugeReport.htm files to a directory (both files must reside in the same directory). Open SmartSSDWearGaugeReport.htm in the browser. Known Issues ------------ N/A Feedback -------- * For support for HPSSADUCLI or Smart Array controllers, please visit the web at http://support.hp.com.