========================================================================== Release Notes -------------------------------------------------------------------------- Important: Some of the Linux RPMs require the target server to be rebooted after the RPM is installed. There is no eReboot neededf message reported on the HP Smart Update Manager 4.0.0 'Installation Results' screen. Therefore, it is recommended to reboot the target server after installation of any Linux RPMs. Below is the list of RPMS which require a reboot: HP ProLiant Smart Array Controller Driver - Cpq_cciss HP U320 SCSI Adapter, SAS HBA with RAID, SCxxXe and SCxxGe series HBA Driver - Mptlinux HP Smart Array B110i SATA RAID Controller Driver - Hpahcisr HP NC-Series Broadcom 1/10 GbE Multifunction and iSCSI Drivers for Linux HP NC-Series ServerEngines be2iscsi Driver for Linux HP NC-Series ServerEngines be2net 10GbE Driver for Linux HP NC-Series Intel E1000 Driver for Linux HP NC-Series Intel E1000e Driver for Linux HP NC-Series Intel igb Driver for Linux HP NC-Series Mellanox 10GbE Driver for Linux HP NC-Series QLogic Driver for Linux HP NC-Series Broadcom TG3 Driver for Linux QLogic iSCSI Driver for Linux ========================================================================== Install Instructions -------------------------------------------------------------------------- Prerequisites: Installing these updates requires legacy compatibility libraries be loaded. The autorun script will detect missing libraries and prompt for their installation. For example, under SLES 11 32 or 64 bit, you must install the compatibility RPM package. The command interpreter (shell) /bin/bash must be installed. For autorun capabilties, the system must be running X with a window manager and an installed browser. For some distributions, the CD must be mounted and the ./autorun command executed for autorun to function. Note: Starting with Linux HP ProLiant Support Pack 8.40 and later, please ensure the following RPMs are also installed. For SLES 11 x86 servers: perl (needed to provide the libperl.so) compat-libstdc++-296-2.96-132.7.2.i386 or later libstdc++33-3.3.3-11.9.i586 or later perl-SNMP-5.4.2.1-6.3.i586 or later net-snmp-5.4.2.1-6.3.i586 or later libnl (needed for QLogic and Emulex drivers) The following RPMs needed only on the local Linux system running HP SUM to perform builds of NIC source RPMs) gcc-2.96-108.1 or later kernel-devel (needed to build RPMs from source. Especially for Red Hat Enterprise Server 5.3 and 5.4, please be sure to install the kernel-devel in addition to any kernel specific devel package such as kernel-xen-devel or kernel-PAE-devel) RPM build tools -------------------------------------------------------------------------------- To ensure the integrity of your download, HP recommends verifying your results with this MD5 Checksum value: af45ccc161fcea135dc8224da744a4f2 psp-8.50.sles11.i686.en.tar.gz Installation: Installation of the Linux HP ProLiant Support Pack Using Autorun: PSP's may be installed via autorun if autorun is configured on the target Linux server. Red Hat distributions include autorun. If autorun is not installed, it must be installed and properly configured before beginning. Autorun will typically mount the CD-ROM on /media/cdrom for Red Hat Enterprise Linux 4 and SUSE-based distributions. Note: Red Hat Enterprise Linux 5 and SUSE LINUX Enterprise Server 10 SP2 automount the CD with the noexec property set. In order to run Autorun, the CD must be first be unmounted and then manually remounted. For other distributions, several autorun utilities are available for download from various Internet sites. These distributions will typically mount the CD-ROM on /media/cdrom. For the purposes of these instructions, the CD-ROM is assumed to have been mounted on /mnt/mnt. The actual mount point should replace /mnt/mnt when executing these instructions. Installation of the Linux HP ProLiant Support Pack using SmartStart CD:. Login on the console as root. Insert the CD. If autorun is activated, skip the next step. If autorun is not activated, manually mount the CD and execute the autorun script (e.g. /mnt/mnt/autorun). On the End User License Agreement screen of autorun, select the Agree button if you agree with the terms of the agreement and wish to proceed with autorun. Select Disagree if you do not agree with the terms of the agreement and wish to exit autorun. Select the Software tab. Select the "Install the HP ProLiant Support Pack" option to install the desired Linux PSP. Manual Installation of the Linux HP ProLiant Support Pack: For the remainder of this discussion, the CD mount directory will be considered to be /mnt/mnt. The actual mount point should replace /mnt/mnt when executing these instructions. Red Hat Enterprise Linux 4 and SUSE-based distributions mount CD's on /media/cdrom. If the CD-ROM mount point is not defined in /etc/fstab, a complete mount command will be required. Login on the console as root. Insert the SmartStart CD. Mount the CD (e.g. mount /mnt/mnt or mount -t iso9660 /dev/cdrom /mnt/mnt). Change to the /compaq/csp/linux directory. Execute the ./hpsum command to install the Linux HP ProLiant Support Pack. The installer will open an interactive session which will allow you to install the Linux HP ProLiant Support Pack. /end