Release Notes for ProLiant Support Pack for SUSE LINUX Enterprise Server 11 (i686), v8.25 and ProLiant Support Pack for SUSE LINUX Enterprise Server 11 (x86_64), v8.25 -------------------------------------------------------------------------------- HP ProLiant Smart Array Controller (x86/AMD32) Driver for SUSE LINUX Enterprise Server 11 (x86) and HP ProLiant Smart Array Controller (AMD64/EM64T) Driver for SUSE LINUX Enterprise Server 11 (AMD64/EM64T) Version: 4.6.20-22 Related File: cpq_cciss-4.6.20-22.sles11.i586.rpm and cpq_cciss-4.6.20-22.sles11.x86_64.rpm Fix Note: Updated Rpm code to make installs on xen configuration more robust. Enhancement Note: Added Support for HP Smart Array P712m controller. Added Support for SUSE LINUX Enterprise Server 11. -------------------------------------------------------------------------------- HP U320 SCSI Adapter, SAS HBA with RAID, SCxxXe and SCxxGe series HBA (x86) Driver for SUSE LINUX Enterprise Server 11 (x86) and HP U320 SCSI Adapter, SAS HBA with RAID, SCxxXe and SCxxGe series HBA (AMD64/EM64T) Driver for SUSE LINUX Enterprise Server 11 (AMD64/EM64T) Version: 4.00.13.05-3.sles11 Related File: mptlinux-4.00.13.05-3.sles11.i586.rpm and mptlinux-4.00.13.05-3.sles11.x86_64.rpm Enhancement Note: New support. ----------------------------------------------------------------------------- HP NC-Series Intel Driver for Linux Version: 8.0.6-3 Related File: e1000-8.0.6-3.src.rpm Fix Note: SUSE Linux Enterprise Server 11 modules now load as "supported: external." -------------------------------------------------------------------------------- HP NC-Series Intel e1000e Driver for Linux Version: 0.4.1.12-3 Related File: e1000e-0.4.1.12-3.src.rpm Fix Note: SUSE Linux Enterprise Server 11 modules now load as "supported: external." -------------------------------------------------------------------------------- HP NC-Series Broadcom 1Gb and 10GbE Multifunction Driver for Linux Version: 4.8.22-2 Related File: netxtreme2-4.8.22-2.src.rpm Fix Note: SUSE Linux Enterprise Server 11 modules now load as "supported: external." -------------------------------------------------------------------------------- HP NC-Series Broadcom TG3 Driver for Linux Version: 3.98e-3 Related File: tg3-3.98e-3.src.rpm Fix Note: This driver no longer fails to install when the /lib/modules/{KVER}/updates directory does not exist. -------------------------------------------------------------------------------- HP NC-Series NetXen Driver for Linux Version: 4.0.304-2 Related File: nx_nic-4.0.304-2.src.rpm Fix Note: SUSE Linux Enterprise Server 11 modules now load as "supported: external." -------------------------------------------------------------------------------- HP NC-Series Intel igb Driver for Linux Version: 1.3.8.6-2 Related File: igb-1.3.8.6-2.src.rpm Enhancement Note: This driver now supports SUSE LINUX Enterprise Server 11. -------------------------------------------------------------------------------- HP OpenIPMI Device Driver for SUSE LINUX Enterprise Server 11 (x86) and HP OpenIPMI Device Driver for SUSE LINUX Enterprise Server 11 (x86_64) Version: 8.2.5-34.sles11 Related File: hp-OpenIPMI-8.2.5-34.sles11.i386.rpm and hp-OpenIPMI-8.2.5-34.sles11.x86_64.rpm Enhancement Note: Initial release. -------------------------------------------------------------------------------- HP System Health Application and Command Line Utilities for SUSE LINUX Enterprise Server 11 (x86) and HP System Health Application and Command Line Utilities for SUSE LINUX Enterprise Server 11 (x86_64) Version: 8.2.5-50.sles11 Related File: hp-health-8.2.5-50.sles11.i386.rpm and hp-health-8.2.5-50.sles11.x86_64.rpm Enhancement Note: Initial release. -------------------------------------------------------------------------------- HP SNMP Agents for SUSE LINUX Enterprise Server 11 (x86) and HP SNMP Agents for SUSE LINUX Enterprise Server 11 (x86_86) Version: 8.2.5-50.sles11 Related File: hp-snmp-agents-8.2.5-50.sles11.i386.rpm and hp-snmp-agents-8.2.5-50.sles11.x86_64.rpm Fix Note: Fixed an issue where Linux event daemon reported RAID 1 inconsistency events. Fixed an issue where cmaidad agents send bad request commands to HP P700m Smart Array controller. Fixed an issue with inconsistent data by setting Monitor and performance data buffers to zero before issuing ioctls to HP Smart Array B110i SATA raid controller. Fixed an issue where HP Smart Array B110i SATA raid controller was displayed twice as HP Smart Array B110i SATA raid controller and standard IDE controller. Fixed an issue where incorrect PCA Part number and system ID details sent in trap email. Fixed an issue where agent crashed when multiple VLANs are created and link up/down events are generated. Fixed an issue with displaying HP BL p-Class rack data in the System Management HomePage. Fixed an issue where cmahealthd sends the 6064 trap correctly when correctable memory errors are occurred. Fixed an issue where System Management Homepage correctly displays the FB DDR3 DIMM type information. Fixed an issue on HP ProLiant DL320 G6 server where the 6018 trap is not sent correctly when the temperature sensors are overheated. Fixed the customer issue to use bond IP while sending traps if bondX is chosen as param in cma.conf. Fixed problem with cmarackd startup. Enhancement Note: Initial release. -------------------------------------------------------------------------------- HP System Management Homepage for Linux (x86) Version: 3.0.1-73 Related File: hpsmh-3.0.1-73.i386.rpm Fix Note: Addressed the following vulnerabilities: CVE-2008-5814: Cross-site scripting (XSS) vulnerability in PHP, possibly 5.2.7 and earlier, when display_errors is enabled, allows remote attackers to inject arbitrary web script or HTML via unspecified vectors. CVE-2008-5557: Heap-based buffer overflow in ext/mbstring/libmbfl/filters/mbfilter_htmlent.c in the mbstring extension in PHP 4.3.0 through 5.2.6 allows context-dependent attackers to execute arbitrary code via a crafted string containing an HTML entity, which is not properly handled during Unicode conversion, related to the (1) mb_convert_encoding, (2) mb_check_encoding, (3) mb_convert_variables, and (4) mb_parse_str functions. "message.php" page is vulnerable to XSS. Enhancement Note: Updated PHP and OpenSSL libraries -------------------------------------------------------------------------------- HP System Management Homepage Templates for Linux Version: 8.2.5-41 Related File: hp-smh-templates-8.2.5-41.noarch.rpm Important Note: The HP System Health Application and Insight Management Agents (hpasm) version 8.0.0 was split into three individual rpm packages: HP System Health Application and Command Line Utilities (hp-health) version 8.1.0 HP SNMP Agents (hp-snmp-agents) version 8.1.0 HP System Management Homepage Templates (hp-smh-templates) version 8.1.0 These three packages provide equivalent functionality as hpasm v8.0.0 and allow for a more modular installation choices. Fix Note: Fixed an issue where the memory subsystem was showing the correctable memory error as uncorrectable error in System Management Homepage. Fixed an issue where the logical serial number was not getting displayed correctly in System Management Homepage on blade servers. Fixed an issue where the status icon for processor utilization was not getting displayed correctly. Enhancement Note: Added support for SUSE LINUX Enterprise Server 11. -------------------------------------------------------------------------------- HP Array Configuration Utility for Linux Version: 8.28-13.0 Related File: cpqacuxe-8.28-13.0.noarch.rpm Enhancement Note: Changes for ACU 8.28.X.X: Diagnostics (ADU - Array Diagnostic Utility) is now integrated with ACU (Array Configuration Utility) GUI interface and icon updates Tabs control for major task categories...Configuration, Diagnostics, and Wizards Controller/Device Dropdown control for selecting controllers and devices System Status section displays the overall issue status count Transactions from tasks are committed to the controller as soon as the Save or Next button is clicked This behavior is new for ACU but similar to how HPACUCLI has always performed Systems and Devices Tree supports right mouse click for faster access to available tasks Systems and Devices Tree section can be extended by dragging the mouse to show more text information Available Tasks section supports a Mini-FAQ description to guide users for task selection ACU now supports context sensitive Help when in a task Supports collapsible header sections to simplify viewing of information Keyboard controls for accessibility Keyboard shortcuts for common tasks Scripting for captures and inputs is no longer supported in ACU HPACUCLI is now responsible for Scripting New SSP (Selective Storage Presentation) interface accessible from the Access Control (SSP) Tab if applicable -------------------------------------------------------------------------------- HP Array Configuration Utility CLI for Linux Version: 8.28-13.0 Related File: hpacucli-8.28-13.0.noarch.rpm Enhancement Note: Changes for HPACUCLI 8.28.X.X: Command Line Diagnostics (ADUCLI) is now integrated with HPACUCLI Scripting for captures and inputs is now intergrated with HPACUCLI This support was previously delivered with ACU The scripting command has changed from cpqacuxe to hpacuscripting -------------------------------------------------------------------------------- HP Version Control Agent for Linux Version: 2.2.1-2 Related File: hpvca-2.2.1-2.linux.rpm Fix Note: Fixed RPM pckage consistancy errors and warnings ( rpm -V ) Enhancement Note: VCA package is now a non interactive RPM package Added command line configuration tool. -------------------------------------------------------------------------------- HP Insight Diagnostics Online Edition for Linux Version: 8.2.5-7 Related File: hpdiags-8.2.5-7.linux.i586.rpm Enhancement Note: Added new hardware support. -------------------------------------------------------------------------------- HP Fibre Channel Enablement Kit for Linux Version: 1.1-4 Related File: hp-fc-enablement-1.1-4.noarch.rpm Enhancement Note: Initial version -------------------------------------------------------------------------------- HP Lights-Out Online Configuration Utility for Linux Version: 1.9.0-3 Related File: hponcfg-1.9.0-3.noarch.rpm Fix Note: Hponcfg 1.9 is updated to work with the new driver package that is present in ProLiant Support Pack 8.20. -------------------------------------------------------------------------------- Copyright 2003-2009 Hewlett-Packard Development Company, L.P.