Release Notes for ProLiant Support Pack for SUSE LINUX Enterprise Server 9 (i686), v8.20 and Release Notes for ProLiant Support Pack for SUSE LINUX Enterprise Server 9 (x86_64), v8.20 -------------------------------------------------------------------------------- HP StorageWorks QLogic Fibre Channel Driver for 2.6.x Kernels Version: 8.02.11-6 Related File: hp_qla2x00src-8.02.11-6.noarch.rpm Fix Note: Prevent installation on updates greater than RHEL 5.2, SLES 10 SP 2 and OEL 5.2. -------------------------------------------------------------------------------- HP StorageWorks QLogic Fibre Channel Driver for c-Class Blade Servers Version: 8.01.07.25-4 Related File: hp_qla2x00src-mezz-8.01.07.25-4.noarch.rpm Fix Note: Prevent installation on updates greater than RHEL 5.2, SLES 10 SP 2 and OEL 5.2. -------------------------------------------------------------------------------- HP Linux Driver Kit for Emulex Based Fibre Channel Host Bus Adapters for 2.6.x Kernels Version: 8.2.0.22-7 Related File: hp-lpfc-8.2.0.22-7.noarch.rpm Fix Note: Prevent installation on updates greater than RHEL 5.2, SLES 10 SP 2 and OEL 5.2. -------------------------------------------------------------------------------- HP ProLiant Smart Array Controller (x86/AMD32) Driver for SUSE LINUX Enterprise Server 9 (x86) HP ProLiant Smart Array Controller (AMD64/EM64T) Driver for SUSE LINUX Enterprise Server 9 (AMD64/EM64T) Version: 2.6.20-16 Related File: cpq_cciss-2.6.20-16.sles9.i686.rpm cpq_cciss-2.6.20-16.sles9.x86_64.rpm Fix Note: Improved driver robustness when adding and deleting LUNs. Improved driver information reported by the modinfo command. Enhancement Note: Added support for the following controllers: HP Smart Array P212 controller HP Smart Array P410 controller HP Smart Array P411 controller -------------------------------------------------------------------------------- HP ProLiant 64-Bit/66-Mhz Dual Channel Wide Ultra3 SCSI Controller Driver for SUSE Linux Enterprise Server 9 (x86) HP ProLiant 64-Bit/66-Mhz Dual Channel Wide Ultra3 SCSI Controller Driver for SUSE Linux Enterprise Server 9 (EM64T) Version: 6.3.11-9 Related File: aic7xxx-6.3.11-9.sles9.i686.rpm aic7xxx-6.3.11-9.sles9.x86_64.rpm Enhancement Note: Added support for new errata kernels. -------------------------------------------------------------------------------- HP 6-Port SATA RAID Controller Driver for SUSE Linux Enterprise Server 9 (AMD32/x86) HP 6-Port SATA RAID Controller Driver for SUSE Linux Enterprise Server 9 (AMD64/EM64T) Version: 1.1.5.2421-8 Related File: aacraid-1.1.5.2421-8.sles9.i686.rpm aacraid-1.1.5.2421-8.sles9.x86_64.rpm Enhancement Note: Added support for new errata kernels. -------------------------------------------------------------------------------- HP U320 SCSI Adapter, SAS HBA with RAID, SCxxXe and SCxxGe series HBA (x86 and AMD32) Driver for Linux Enterprise Server 9 (x86) HP U320 SCSI Adapter, SAS HBA with RAID, SCxxXe and SCxxGe series HBA (AMD64/EM64T) Driver for Linux Enterprise Server 9 (AMD64/EM64T) Version: 3.12.14.00-4 Related File: mptlinux-3.12.14.00-4.sles9.i686.rpm mptlinux-3.12.14.00-4.sles9.x86_64.rpm Fix Note: There are no changes from the previous version 3.12.14.00-2. The driver has spun to comply with internal Hewlett Packard Commonality Specifications. Customers only need to update if their driver is 3.12.14.00-1 or earlier. Enhancement Note: Added support for the HP SC08Ge SAS Host Bus Adapter -------------------------------------------------------------------------------- HP NC-Series Intel Driver for Linux Version: 8.0.6-1 Related File: e1000-8.0.6-1.src.rpm Enhancement Note: This driver no longer supports the following network adapters: NC110T NC360m NC360T NC364m NC364T These network adapters are now supported by the HP NC-Series Intel e1000e Driver for Linux. -------------------------------------------------------------------------------- HP NC-Series Intel e1000e Driver for Linux Version: 0.4.1.12-1 Related File: e1000e-0.4.1.12-1.src.rpm Enhancement Note: Initial release. -------------------------------------------------------------------------------- HP NC-Series Broadcom 1Gb and 10GbE Multifunction Driver for Linux Version: 4.8.2-2 Related File: netxtreme2-4.8.2-2.src.rpm Fix Note: This driver now interacts properly with netdump, so you can get core dumps. Enhancement Note: This rpm contains drivers that support Broadcom 1Gb and 10GbE Multifunction network adapters. It replaces the following rpms: HP NC-Series Broadcom 1Gb Multifunction Driver for Linux HP NC-Series Broadcom 10GbE Multifunction Driver for Linux -------------------------------------------------------------------------------- HP NC-Series Broadcom TG3 Driver for Linux Version: 3.92n-2 Related File: tg3-3.92n-2.src.rpm Enhancement Note: The spec file in this rpm has been modified to drop the module in the updates directory. -------------------------------------------------------------------------------- HP NC-Series NetXen Driver for Linux Version: 4.0.230-1 Related File: nx_nic-4.0.230-1.src.rpm Enhancement Note: This driver now supports the NC375i, NC522SFP and NC524SFP network adapters. -------------------------------------------------------------------------------- HP NC-Series NetXen Linux Socket Acceleration Version: 4.0.225-1 Related File: nx_lsa-4.0.225-1.src.rpm Enhancement Note: This software now supports the NC375i, NC522SFP and NC524SFP network adapters. -------------------------------------------------------------------------------- QLogic iSCSI Driver for Linux Version: 5.01.01.04-1 Related File: qla4xxx-5.01.01.04-1.src.rpm Enhancement Note: Initial release. -------------------------------------------------------------------------------- HP NC-Series Intel igb Driver for Linux Version: 1.3.8.6-1 Related File: igb-1.3.8.6-1.src.rpm Enhancement Note: Initial release. -------------------------------------------------------------------------------- HP OpenIPMI Device Driver for SUSE LINUX Enterprise Server 9 (x86) HP OpenIPMI Device Driver for SUSE LINUX Enterprise Server 9 (AMD64/EM64T) Version: 8.2.0-285.sles9 Related File: hp-OpenIPMI-8.2.0-285.sles9.i386.rpm hp-OpenIPMI-8.2.0-285.sles9.x86_64.rpm Enhancement Note: Added support for HP ProLiant G6 servers. -------------------------------------------------------------------------------- HP ProLiant Channel Interface for SUSE LINUX Enterprise Server 9 (x86) HP ProLiant Channel Interface for SUSE LINUX Enterprise Server 9 (AMD64/EM64T) Version: 8.2.0-236.sles9 Related File: hp-ilo-8.2.0-236.sles9.i386.rpm hp-ilo-8.2.0-236.sles9.x86_64.rpm Enhancement Note: Package modified to use upstream hpilo channel interface driver. -------------------------------------------------------------------------------- HP System Health Application and Command line Utilities for SUSE LINUX Enterprise Server 9 (x86) HP System Health Application and Command Line Utilities for SUSE LINUX Enterprise Server 9 (AMD64/EM64T) Version: 8.2.0-283.sles9 Related File: hp-health-8.2.0-283.sles9.i386.rpm hp-health-8.2.0-283.sles9.x86_64.rpm Important Note: The HP System Health Application and Insight Management Agents (hpasm) version 8.0.0 was split into three individual rpm packages: HP System Health Application and Command Line Utilities (hp-health) version 8.1.0 HP SNMP Agents (hp-snmp-agents) version 8.1.0 HP System Management Homepage Templates (hp-smh-templates) version 8.1.0 These three packages provide equivalent functionality as hpasm v8.0.0 and allow for a more modular installation choice. Fix Note: Fixed an issue where hpasmcli does segmentation fault if we execute the following sequence of commands in hpasmcli on Intel platforms: show dimm, show temp, show dimm. Fixed the improper functioning of repair option in hpasmcli utility. Fixed an issue where hpasmxld/hpasmlited was logging all the messages into syslog with priority "error". Now it will log each message with its actual priority. Fixed an issue where IML was not showing new events in hpasmlited + OpenIPMI configuration. Fixed an issue where the command "service hp-health restart" was showing the twice Enhancement Note: Added support for HP ProLiant G6 servers. ASR time-out value can be set from hpasmcli when ASR is enabled. Updated the installation instructions in hp_mgmgt_install man page. Removed the script dependency between the hp-health and hp-snmp-agents RPM. To enable just storage agents, customers now install the hp-health and hp-snmp-agents. If the "/etc/init.d/hp-health" file is removed or renamed, the storage agents will start if configured in the /opt/hp/hp-snmp-agents/cma.conf file. Init scripts "status"¯ function for hp-snmp-agents & hp-health now differentiates whether an agent exited normally or abnormally. libcpqci moved to hp-health to simplify dependency handling¯ and libcpqci updated to version 2, will now handle hpilo driver. Added Trusted Platform Module (TPM) awareness. -------------------------------------------------------------------------------- HP SNMP Agents for SUSE LINUX Enterprise Server 9 (x86) HP SNMP Agents for SUSE LINUX Enterprise Server 9 (AMD64/EM64T) Version: 8.2.0-284.sles9 Related File: hp-snmp-agents-8.2.0-284.sles9.i386.rpm hp-snmp-agents-8.2.0-284.sles9.x86_64.rpm Important Note: The HP System Health Application and Insight Management Agents (hpasm) version 8.0.0 was split into three individual rpm packages: HP System Health Application and Command Line Utilities (hp-health) version 8.1.0 HP SNMP Agents (hp-snmp-agents) version 8.1.0 HP System Management Homepage Templates (hp-smh-templates) version 8.1.0 These three packages provide equivalent functionality as hpasm v8.0.0 and allow for a more modular installation choices. Fix Note: Fixed an issue where the cmasm2d agent used to log the following error in cma.log after an iLO reset had been occurred: "cmasm2d[7880]: sm2_ioctl: Index mismatch 50 != 51, retrying receive". Fixed an issue when a fan removed or failed, the overall thermal and fan status will be updated correctly in System Management Homepage. Fixed an issue where the System Management Homepage was not displaying the file system details of a USB key after unmounting and mounting it again. Fixed an issue where the agents used to send the trap email twice after a restart. The shut down notification sent by cmapeerd daemon is now acknowledged by all agents before the cmapeerd shuts down. This will eliminate the sporadic error messages logged by the agents during shut down. The build number will now increment when the hp-snmp-agents rebuild. Enhancement Note: Added support for HP ProLiant G6 servers. Added Trusted Platform Module (TPM) awareness. Removed the script dependency between the hp-health and hp-snmp-agents RPM. To enable just storage agents, customers now install the hp-health and hp-snmp-agents. If the "/etc/init.d/hp-health" file is removed or renamed, the storage agents will start if configured in the /opt/hp/hp-snmp-agents/cma.conf file. Enabled the selective bubbling up of events in Integrated Management Log. Init scripts status¯ function for hp-snmp-agents & hp-health now differentiates whether an agent exited normally or abnormally. Added support for CpqHeResMem2 MIBs. The following MIB tables have been deprecated. These tables will be removed in a future release: cpqSiMemModuleTable, cpqHeResMemBoardTable, cpqHeResMemModuleTable. The data in these tables will be available in the new cpqHe2ResMemModuleTable & cpqHe2ResMemBoardTable MIB tables. -------------------------------------------------------------------------------- HP System Management Homepage for Linux (x86) HP System Management Homepage for Linux (AMD64/EM64T) Version: 3.0.0-68 Related File: hpsmh-3.0.0-68.i386.rpm hpsmh-3.0.0-68.x86_64.rpm Fixes: Improved security Enhancement Note: Session Persistence SIM communication through secure port and support to enable/disable non-secure port (2301) IPv6 support New interface and icons Per-user UI preferences Command line interface for SMH configuration XEN server support VMware 3.5 support Log localization Apache 2.2.6 OpenSSL 0.9.8h PHP 5.2.6 libxml2 2.7.2 -------------------------------------------------------------------------------- HP System Management Homepage Templates for Linux Version: 8.2.0-282 Related File: hp-smh-templates-8.2.0-282.noarch.rpm Important Note: The HP System Health Application and Insight Management Agents (hpasm) version 8.0.0 was split into three individual rpm packages: HP System Health Application and Command Line Utilities (hp-health) version 8.1.0 HP SNMP Agents (hp-snmp-agents) version 8.1.0 HP System Management Homepage Templates (hp-smh-templates) version 8.1.0 These three packages provide equivalent functionality as hpasm v8.0.0 and allow for a more modular installation choices. Enhancement Note: Updated the templates to display the CPU/Memory subsystem information on HP ProLiant G6 servers. Updated the help pages for the sections: System Board, Integrated Management Log, CPU Usage, Memory Subsystem, Environment, C-class enclosure, Power Supply, iLO. Added Trusted Platform Module (TPM) awareness. The ASR time-out value can now be set from System Management Homepage if the ASR has been enabled. -------------------------------------------------------------------------------- HP Version Control Agent for Linux Version: 2.2.0-9 Related File: hpvca-2.2.0-9.linux.rpm Fixes: When primary node is down in clustered VCRM, PSP deployment through VCA fails Enhancement Note: Supports IPV6 New! Support for online system firmware update. New! Ability to select and install multiple components. New! Ability to install RPM packages. -------------------------------------------------------------------------------- HP iLO2 High-Performance Mouse for Linux Version: 1.1.1-41 Related File: hpmouse-1.1.1-41.noarch.rpm Enhancement Note: Added code to accept any variance of "Yes" will work for HPMOUSESILENT. -------------------------------------------------------------------------------- HP Array Configuration Utility for Linux Version: 8.25-5 Related File: cpqacuxe-8.25-5.noarch.rpm Enhancement Note: Added Support for the following Controllers: Smart Array P212 Smart Array P212 ZMR Smart Array P410 Smart Array P410 ZMR Smart Array P410i Smart Array P410i ZMR Smart Array P411 Smart Array P411 ZMR Smart Array B110i SATA RAID Additionally, added support for Advanced Pack -------------------------------------------------------------------------------- HP Array Configuration Utility CLI for Linux Version: 8.25-5 Related File: hpacucli-8.25-5.noarch.rpm Enhancement Note: Added Support for the following Controllers: Smart Array P212 Smart Array P212 ZMR Smart Array P410 Smart Array P410 ZMR Smart Array P410i Smart Array P410i ZMR Smart Array P411 Smart Array P411 ZMR Smart Array B110i SATA RAID Additionally, added support for Advanced Pack -------------------------------------------------------------------------------- HP Array Diagnostics Utility for Linux Version: 8.25-5 Related File: hpadu-8.25-5.noarch.rpm Enhancement Note: Added Support for the following Controllers: Smart Array P212 Smart Array P212 ZMR Smart Array P410 Smart Array P410 ZMR Smart Array P410i Smart Array P410i ZMR Smart Array P411 Smart Array P411 ZMR Smart Array B110i SATA RAID Additionally, added support for Advanced Pack -------------------------------------------------------------------------------- HP Insight Diagnostics Online Edition for Linux Version: 8.2.0-479 Related File: hpdiags-8.2.0-479.linux.i586.rpm Enhancement Note: Added new hardware support. -------------------------------------------------------------------------------- Fibre Channel Utilities for HP StorageWorks FCA2214/FCA2214DC FC HBA for Linux (x86) Fibre Channel Utilities for HP StorageWorks FCA2214/FCA2214DC FC HBA for Linux (AMD64/EM64T) Version: 2.5-4 Related File: fibreutils-2.5-4.linux.i386.rpm fibreutils-2.5-4.linux.x86_64.rpm Fix Note: - Add preinstall checks so that version 2.x of fibreutils does not install on RHEL 5.3 or greater - Fixed problem in lssd printing sdsd* device names - Add support for a five character device name is lssd - Changes to RPM to comply with RPM commonality spec. - Fix grep statement that parses /sys/block for sd devices in lssd - Fixed adapter_info -L flag on SLES 9 SP 4 - Fixed printing QLogic driver version in adapter_info -------------------------------------------------------------------------------- HP Lights-Out Online Configuration Utility for Linux Version: 1.9.0-3 Related File: hponcfg-1.9.0-3.noarch.rpm Fixes: Hponcfg 1.9 is updated to work with the new driver package that is present in ProLiant Support Pack 8.20. -------------------------------------------------------------------------------- Copyright 2003-2009 Hewlett-Packard Development Company, L.P.