Release Notes for ProLiant Support Pack for SUSE LINUX Enterprise Server 9, v8.10 Following is the list of the fixes and/or enhancements for all components in either the 8.00 x86 or x86_64 SUSE LINUX Enterprise Server 9 support packs. ******************************** hp_qla2x00src-8.01.07.25-2.linux.noarch.rpm - HP StorageWorks FCA2214/FCA2214DC FC HBA Driver for 2.6.x Kernels, v8.01.07.25-2 Enhancements Added 8.01.07.25 adapter driver Added support for auto-failback on MSA active-active arrays and EVA4000/6000/8000 Added support for HP XP Array static load balancing ******************************** hp-lpfc-8.0.16.32-4.linux.rpm - HP Linux Driver Kit for Emulex Based Fibre Channel Host Bus Adapters for 2.6.x Kernels, v8.0.16.32-4 Enhancements Added 8.0.16.32 Emulex base driver Changed default number of discovery threads (outstanding login sessions) from 1 to 32 ******************************** cpq_cciss-2.6.18-16.sles9.i586.rpm - HP ProLiant Smart Array Controller (x86/AMD32) Driver for SUSE LINUX Enterprise Server 9 (x86), v2.6.18-16 Fixes Includes fix for LifeKeeper to address zero Lun size on failover, Sg_io error handling issues and code reordering for optimization ******************************** cpq_cciss-2.6.18-16.sles9.x86_64.rpm - HP ProLiant Smart Array Controller (AMD64/EM64T) Driver for SUSE LINUX Enterprise Server 9 (AMD64/EM64T), v2.6.18-16 Fixes Includes fix for LifeKeeper to address zero Lun size on failover, Sg_io error handling issues and code reordering for optimization ******************************** aic7xxx-6.3.11-9.sles9.x86_64.rpm - HP ProLiant 64-Bit/66-Mhz Dual Channel Wide Ultra3 SCSI Controller Driver for SUSE Linux Enterprise Server 9 (AMD64/EM64T), v6.3.11-9 Enhancements Added support for new errata kernels. ******************************** aic7xxx-6.3.11-9.sles9.i586.rpm - HP ProLiant 64-Bit/66-Mhz Dual Channel Wide Ultra3 SCSI Controller Driver for SUSE LINUX Enterprise Server 9 (AMD32/x86), v6.3.11-9 Enhancements Added support for new errata kernels. ******************************** aacraid-1.1.5.2421-8.sles9.i586.rpm - HP 6-Port SATA RAID Controller Driver for SUSE Linux Enterprise Server 9 (AMD32/x86), v1.1.5.2421-8 Enhancements Added support for new errata kernels. ******************************** aacraid-1.1.5.2421-8.sles9.x86_64.rpm - HP 6-Port SATA RAID Controller Driver for SUSE Linux Enterprise Server 9 (AMD64/EM64T), v1.1.5.2421-8 Enhancements Added support for new errata kernels. ******************************** mptlinux-3.12.14.00-2.sles9.x86_64.rpm - HP U320 SCSI Adapter, SAS HBA with RAID, SCxxXe and SCxxGe series HBA (AMD64/EM64T) Driver for SUSE LINUX Enterprise Server 9 (AMD64/EM64T), v3.12.14.00-2 Fixes Fixed an issue where not all hard drive details where available when a hard drive within RAID 1 volume failed. Enhancements Added support for SP4. ******************************** mptlinux-3.12.14.00-2.sles9.i586.rpm - HP U320 SCSI Adapter, SAS HBA with RAID, SCxxXe and SCxxGe series HBA (x86 & AMD32) Driver for SUSE LINUX Enterprise Server 9 (x86), v3.12.14.00-2 Fixes Fixed an issue where not all hard drive details where available when a hard drive within RAID 1 volume failed. Enhancements Added support for SP4. ********************************* e1000-7.6.15a-1.src.rpm - HP NC-Series Intel Driver for Linux, v7.6.15a-1 Fixes Driver will not work in 2.6.24 kernel in NAPI. Driver fails to build with -DE1000_NO_NAPI on kernels < 2.6.24-rc3. Panic when changing RX/TX ring values beyond 4096. Cannot pass traffic after dis/reconnecting cable. Driver does not acknowledge link status change. Enhancements This driver is the latest available driver from Intel. ******************************** tg3-3.90b-1.src.rpm - HP NC-Series Broadcom TG3 Driver for Linux, v3.90b-1 Enhancements This driver now supports the NC107i network adapter. ******************************** bnx2-1.7.6b-1.src.rpm - HP HP NC-Series Multifunction Driver for Linux, v1.7.6b-1 Fixes This driver now correctly reports link loss on blade servers with the NC370i LOM. This driver now compiles correctly on SLES9.4. Enhancements This driver now supports the HP NC382i, NC382m and NC382T network adapters. ******************************** nx_nic-3.4.336-1.src.rpm - HP Linux Socket Acceleration, v3.4.336-1 Enhancements This software is the latest available from NetXen. ******************************** nx_lsa-3.4.336-1.src.rpm - HP NC-Series NetXen Driver for Linux, v3.4.336-1 Enhancements This driver is the latest driver version available from NetXen. ******************************** hp-OpenIPMI-8.1.0-104.sles9.i386.rpm - HP OpenIPMI Device Driver for SUSE LINUX Enterprise Server 9, Update 6 (x86), v8.1.0-104.sles9, and hp-OpenIPMI-8.1.0-104.sles9.x86_64.rpm - HP OpenIPMI Device Driver for SUSE LINUX Enterprise Server 9 (AMD64/EM64T), v8.1.0-104.sles9 Fixes Minor packaging fixes, including file permissions and rpm header information. Enhancements Package upgrade support (rpm -U). ******************************** hp-ilo-8.1.0-104.sles9.i386.rpm - HP ProLiant Channel Interface for SUSE LINUX Enterprise Server 9 (x86) , v8.1.0-104.sles9, and hp-ilo-8.1.0-104.sles9.x86_64.rpm - HP ProLiant Channel Interface for SUSE LINUX Enterprise Server 9 (AMD64/EM64T) , v8.1.0-104.sles9 Fixes Minor packaging fixes, including file permissions and rpm header information. Enhancements Package upgrade support (rpm -U). ******************************** hp-health-8.1.0-104.sles9.i386.rpm - HP System Health Application and Insight Management Agents for SUSE LINUX Enterprise Server 9 (x86), v8.1.0-104.sles9, and hp-health-8.1.0-104.sles9.x86_64.rpm - HP System Health Application and Command Line Utilities for SUSE LINUX Enterprise Server 9 (AMD64/EM64T), v8.1.0-104.sles9 Enhancements Initial release. ******************************** hp-snmp-agents-8.1.0-110.sles9.i386.rpm - HP SNMP Agents for SUSE LINUX Enterprise Server 9 (x86), v8.1.0-110.sles9, and hp-snmp-agents-8.1.0-110.sles9.x86_64.rpm - HP SNMP Agents for SUSE LINUX Enterprise Server 9 (AMD64/EM64T), v8.1.0-110.sles9 Fixes Fixed the ProLiant Management Command Line Interface Utility (hpasmcli) to display the temperature and fan failure information correctly. Fixed the ProLiant Integrated Management Log (IML) Utility (hplog) to display number of events correctly. Fixed the discrepancy in ASR time-out value displayed on hpasmcli and hplog. Fixed an issue where hpasmcli, hplog and System Management Homepage (hpsmh) were showing different status for CPU fan redundancy in ML350 G5. Fixed an issue where Power supply status of DL585G1 not shown correctly in CLI utilities. Fixed the hpasmcli to display the UID information correctly on ML310 G4. NIC Agent now shows proper link status for Loopback interface (lo). Fixed NIC Agent where it does not generate netsnmp_assert error messages in cma.log file. Fixed NIC Agent to show the correct speed (10Gbps) in the System Management Homepage for 10Gig NICs. Fixed NIC Agent to show the correct Adapter Name for HP NC380T Adapter. Fixed issue where some events may not reported if a large number of physical drives were present. Fixed issue where the device node name was sometimes not reported correctly for Smart array attached drives. Fixed issue where Logical drives shown as none in hpsmh after deleting the first logical drive. Fixed ps/grep race in storage agent (cmastor) startup script. Fixed status of processor SCSI ID reported as unknown. Fixed hpsmh where sometimes shows drive is blinking when it isn't. Fixed re-insertion of hot-plugged fan module generated IPMI failure event. Fixed an issue where cpqriisd was showing error “ daemon: command not found” at startup on SLES9. Fixed an issue where cmapeerd was showing the error message “recvfrom() failed”. Enhancements Initial release. NIC Agent now shows IPV6 address in System Management Homepage (hpsmh) on IPv6 only system. Added fan module number to message logged to syslog for MSA70. Changed "opt/compaq" to "opt/hp/hp-snmp-agents". Updated reported MIB revisions for 8.10 storage agents. Make physical drive path status in the physical drive table report as PATH_STATUS_OTHER if the physical drive status is PHYS_FAILED. Make the path table report path status as "PATH_STATUS_OTHER" when the physical drive status is unknown. ******************************** hpsmh-2.1.12-200.linux.i386.rpm - HP System Management Homepage for Linux (x86), v2.1.12-200, and hpsmh-2.1.12-200.linux.x86_64.rpm - HP System Management Homepage for Linux (AMD64/EM64T), v2.1.12-200 Fixes Fixed a cross-site scripting vulnerability (XSS) ******************************** hp-smh-templates-8.1.0-104.noarch.rpm - HP System Management Homepage Templates for Linux, v8.1.0-104 Fixes Fixed an issue where the C-class enclosure health status was displayed as ‘Unknown’ in System Management Home page. Fixed an issue where cmapeerd was showing the error message “recvfrom() failed”. Fixed an issue where cpqriisd was showing error “ daemon: command not found” at startup on SLES9. Enhancements Initial release. Added the entry 'trapIf' to cma.conf file. This can be used to inform SNMP daemon which IP Address to use for sending the traps if there are multiple NICs configured in the system. ******************************** hpmouse-1.1.1-41.noarch.rpm - HP Version Control Agent for Linux, v1.1.1-41 Enhancements Added code to accept any variance of ‘Yes’ will work for HPMOUSESILENT. ******************************** hpvca-2.1.9-7.linux.rpm - HP Version Control Agent for Linux, v2.1.9-7 Enhancements Support for componentized installer that can be integrated into VCA. ******************************** cpqacuxe-8.10-1.linux.rpm - HP Array Configuration Utility for Linux, v8.10-1 Fixes Updated version number for the 8.10 Linux support pack release. No other changes were made. ******************************** hpacucli-8.10-2.linux.rpm - HP Array Configuration Utility CLI for Linux, v8.10-2 Fixes Fixed an issue related to an incorrect Background Parity Initialization status being displayed for RAID 5 and RAID 6 Logical Drives. ******************************** hpadu-8.10-3.linux.rpm - HP Array Diagnostics Utility for Linux, v8.10-3 Fixes Fixed an issue related to an incorrect Background Parity Initialization status being displayed for RAID 5 and RAID 6 Logical Drives. Enhancements Fixes incorrect Background Parity Initialization status for RAID 5 and RAID 6 Logical Drives. ******************************** hpdiags-8.1.0-136.linux.i386.rpm - HP Insight Diagnostics Online Edition for Linux, v8.1.0-136 Enhancements Bug fixes and tested with new Linux OS supported by LSP. ******************************** fibreutils-2.4-1.linux.i386.rpm - Fibre Channel Utilities for HP StorageWorks FCA2214/FCA2214DC FC HBA for Linux (x86), v2.4-1, and fibreutils-2.4-1.linux.x86_64.rpm - Fibre Channel Utilities for HP StorageWorks FCA2214/FCA2214DC FC HBA for Linux (AMD64/EM64T), v2.4-1 Fixes Build 2.4-1 Added -c options to lssg and lssd Build 2.3-8 Add check to lssg to make sure that /sys/class/scsi_generic exists Build 2.3-7 Fixed LUN parsing issue in probe-luns Build 2.3-6 Fixed a hang when scanning in lssg Build 2.3-5 Changed lssd and lssg to not stop on a scsi_info failure ******************************** hponcfg-1.8.0-1.noarch.rpm - HP Lights-Out Online Configuration Utility for Linux, v1.8.0-1 Enhancements Hponcfg would provide indication to the user about the firmware reset whenever firmware is reset on execution of some XML/RIBCL script. Hponcfg would support use of standard streams. It would allow XML input to be provided over standard input and it would direct the output messages and error messages to proper streams. ******************************** Copyright 2003-2008 Hewlett-Packard Development Company, L.P.