Release Notes for ProLiant Support Pack for SUSE LINUX Enterprise Server 9, v7.90 Following is the list of all the components that changed in 7.90 from 7.80. ******************************** cpq_cciss-2.6.18-5.sles9.i586.rpm - HP ProLiant Smart Array Controller (x86/AMD32) Driver for SUSE LINUX Enterprise Server 9 (x86), v2.6.18-5 Enhancements Increased LUN support per controller to 512. Exporting more attributes to sysfs; raid level, usage_count, show_unique_id, show_lun_id, show_bus, show_model and show_vendor. ******************************** cpq_cciss-2.6.18-5.sles9.x86_64.rpm - HP ProLiant Smart Array Controller (AMD64/EM64T) Driver for SUSE LINUX Enterprise Server 9 (AMD64/EM64T), v2.6.18-5 Enhancements Increased LUN support per controller to 512. Exporting more attributes to sysfs; raid level, usage_count, show_unique_id, show_lun_id, show_bus, show_model and show_vendor. ******************************** aic7xxx-6.3.11-8.sles9.x86_64.rpm - HP ProLiant 64-Bit/66-Mhz Dual Channel Wide Ultra3 SCSI Controller Driver for SUSE Linux Enterprise Server 9 (AMD64/EM64T), v6.3.11-8 Enhancements Added support for new errata kernels. ******************************** aic7xxx-6.3.11-8.sles9.i586.rpm - HP ProLiant 64-Bit/66-Mhz Dual Channel Wide Ultra3 SCSI Controller Driver for SUSE LINUX Enterprise Server 9 (AMD32/x86), v6.3.11-8 Enhancements Added support for new errata kernels. ******************************** aacraid-1.1.5.2421-7.sles9.i586.rpm - HP 6-Port SATA RAID Controller Driver for SUSE Linux Enterprise Server 9 (AMD32/x86), v1.1.5.2421-7 Enhancements Added support for new errata kernels. ******************************** aacraid-1.1.5.2421-7.sles9.x86_64.rpm - HP 6-Port SATA RAID Controller Driver for SUSE Linux Enterprise Server 9 (AMD64/EM64T), v1.1.5.2421-7 Enhancements Added support for new errata kernels. ******************************** mptlinux-3.02.83.20-1.sles9.x86_64.rpm - HP U320 SCSI Adapter, SAS HBA with RAID, SCxxXe and SCxxGe series HBA (AMD64/EM64T) Driver for SUSE LINUX Enterprise Server 9 (AMD64/EM64T), v3.02.83.20-1 Fixes Fixed an issue where minimum required details are not displayed for volumes that are rebuilding or inactive. Fixed an issue where the SAS Address of a failed drive and replaced drive were same. ******************************** mptlinux-3.02.83.20-1.sles9.i586.rpm - HP U320 SCSI Adapter, SAS HBA with RAID, SCxxXe and SCxxGe series HBA (x86 & AMD32) Driver for SUSE LINUX Enterprise Server 9 (x86), v3.02.83.20-1 Fixes Fixed an issue where minimum required details are not displayed for volumes that are rebuilding or inactive. Fixed an issue where the SAS Address of a failed drive and replaced drive were same. ******************************** e1000-7.5.5a-2.src.rpm - HP NC61xx/71xx/310x/340x/360x Gigabit Ethernet NIC Driver for Linux, v7.5.5a-2 Enhancements This driver has been tested on RHEL4 U5. ******************************** tg3-3.77e-1.src.rpm - HP NC10xx/67xx/77xx/150x/320x/324x/325x/326x Tigon3 Gigabit Ethernet NIC Driver for Linux, v3.77e-1 Fixes This release has a driver fix that prevents the system from crashing on some architectures, which allows the user to run without needing to restart the system. The driver contains other fixes to eliminate problems caused by external memory fragmentation, eliminate a crash during driver initialization, and allows the user to run without needing to restart the system. ******************************** bnx2-1.5.10d-2.src.rpm - HP NC370x/371x/373x/374x/380x Gigabit Ethernet NIC Driver for Linux, v1.5.10d-2 Fixes This driver no longer behaves badly when external memory fragmentation occurs, which allows the user to continue smoothly running in the event of such fragmentation. This driver no longer causes a missing link event in some circumstances, which allows the user to continue running smoothly when these events were previously generated. This driver no longer locks up the system under certain race conditions, which allows the user to continue running without the need to reboot the system. This driver will now correctly print PCI or PCIe bus information for all devices, which allows the user to identify the devices. ******************************** hpsmh-2.1.10-186.linux.i386.rpm - HP System Management Homepage for Linux (x86), v2.1.10-186 Fixes Addressed the following vulnerabilities: CVE-2007-1717: The mail function in PHP 4.0.0 through 4.4.6 and 5.0.0 through 5.2.1 truncates e-mail messages at the first ASCIIZ ('\0') byte, which might allow context-dependent attackers to prevent intended information from being delivered in e-mail messages. NOTE: this issue might be security-relevant in cases when the trailing contents of e-mail messages are important, such as logging information or if the message is expected to be well-formed. CVE-2007-1711: Double free vulnerability in the unserializer in PHP 4.4.5 and 4.4.6 allows context-dependent attackers to execute arbitrary code by overwriting variables pointing to (1) the GLOBALS array or (2) the session data in _SESSION. NOTE: this issue was introduced when attempting to patch CVE-2007-1701 (MOPB-31-2007). CVE-2007-1583: The mb_parse_str function in PHP 4.0.0 through 4.4.6 and 5.0.0 through 5.2.1 sets the internal register_globals flag and does not disable it in certain cases when a script terminates, which allows remote attackers to invoke available PHP scripts with register_globals functionality that is not detectable by these scripts, as demonstrated by forcing a memory_limit violation. CVE-2007-1582: The resource system in PHP 4.0.0 through 4.4.6 and 5.0.0 through 5.2.1 allows context-dependent attackers to execute arbitrary code by interrupting certain functions in the GD (ext/gd) extension and unspecified other extensions via a userspace error handler, which can be used to destroy and modify internal resources. CVE-2007-1001: Multiple integer overflows in the (1) createwbmp and (2) readwbmp functions in wbmp.c in the GD library (libgd) in PHP 4.0.0 through 4.4.6 and 5.0.0 through 5.2.1 allow context-dependent attackers to execute arbitrary code via Wireless Bitmap (WBMP) images with large width or height values. Enhancements Updated OpenSSL and PHP libraries. ******************************** hpsmh-2.1.10-186.linux.x86_64.rpm - HP System Management Homepage for Linux (AMD64/EM64T), v2.1.10-186 Fixes Addressed the following vulnerabilities: CVE-2007-1717: The mail function in PHP 4.0.0 through 4.4.6 and 5.0.0 through 5.2.1 truncates e-mail messages at the first ASCIIZ ('\0') byte, which might allow context-dependent attackers to prevent intended information from being delivered in e-mail messages. NOTE: this issue might be security-relevant in cases when the trailing contents of e-mail messages are important, such as logging information or if the message is expected to be well-formed. CVE-2007-1711: Double free vulnerability in the unserializer in PHP 4.4.5 and 4.4.6 allows context-dependent attackers to execute arbitrary code by overwriting variables pointing to (1) the GLOBALS array or (2) the session data in _SESSION. NOTE: this issue was introduced when attempting to patch CVE-2007-1701 (MOPB-31-2007). CVE-2007-1583: The mb_parse_str function in PHP 4.0.0 through 4.4.6 and 5.0.0 through 5.2.1 sets the internal register_globals flag and does not disable it in certain cases when a script terminates, which allows remote attackers to invoke available PHP scripts with register_globals functionality that is not detectable by these scripts, as demonstrated by forcing a memory_limit violation. CVE-2007-1582: The resource system in PHP 4.0.0 through 4.4.6 and 5.0.0 through 5.2.1 allows context-dependent attackers to execute arbitrary code by interrupting certain functions in the GD (ext/gd) extension and unspecified other extensions via a userspace error handler, which can be used to destroy and modify internal resources. CVE-2007-1001: Multiple integer overflows in the (1) createwbmp and (2) readwbmp functions in wbmp.c in the GD library (libgd) in PHP 4.0.0 through 4.4.6 and 5.0.0 through 5.2.1 allow context-dependent attackers to execute arbitrary code via Wireless Bitmap (WBMP) images with large width or height values. Enhancements Updated OpenSSL and PHP libraries. ******************************** hp-OpenIPMI-7.9.0-110.sles9.i386.rpm - HP OpenIPMI Device Driver for SUSE LINUX Enterprise Server 9 (x86), v7.9.0-110.sles9 Fixes Resolved issue where hp-OpenIPMI may cause hpasm to hang during the Linux Operating System boot. ******************************** hp-OpenIPMI-7.9.0-110.sles9.x86_64.rpm - HP OpenIPMI Device Driver for SUSE LINUX Enterprise Server 9 (AMD64/EM64T), v7.9.0-110.sles9 Fixes Resolved issue where hp-OpenIPMI may cause hpasm to hang during the Linux Operating System boot. ******************************** hpasm-7.9.0-116.sles9.i586.rpm - HP System Health Application and Insight Management Agents for SUSE LINUX Enterprise Server 9 (AMD64/EM64T), v7.9.0-116.sles9 Fixes Resolved issue where Smart Array agent was not able to detect Operating System assigned names for new logical drives created on-line. Resolved issue where Fibre Channel agent was not able to detect fibre port's status change when fibre link was down. Resolved issue where snmpwalk could not read data from fibre attachment table due to huge table index number. Enhancements Added support for HP Smart Array P700m Controller and HP SC40Ge Host Bus Adapter. Added support to display HP Smart Array controller drive write cache state when the state is enabled. Removed serial log output events from the message queue between cmaeventd and cmaidad to prevent message queue overflow. Updated health agents to handle memory configurations in upcoming server lines. Changed SMBIOS access routines to handle changes made in ROM. ******************************** hpasm-7.9.0-116.sles9.x86_64.rpm - HP System Health Application and Insight Management Agents for SUSE LINUX Enterprise Server 9 (AMD64/EM64T), v7.9.0-116.sles9 Fixes Resolved issue where Smart Array agent was not able to detect Operating System assigned names for new logical drives created on-line. Resolved issue where Fibre Channel agent was not able to detect fibre port's status change when fibre link was down. Resolved issue where snmpwalk could not read data from fibre attachment table due to huge table index number. Enhancements Added support for HP Smart Array P700m Controller and HP SC40Ge Host Bus Adapter. Added support to display HP Smart Array controller drive write cache state when the state is enabled. Removed serial log output events from the message queue between cmaeventd and cmaidad to prevent message queue overflow. Updated health agents to handle memory configurations in upcoming server lines. Changed SMBIOS access routines to handle changes made in ROM. ******************************** hprsm-7.9.0-108.sles9.i586.rpm - HP System Health Application and Insight Management Agents for SUSE LINUX Enterprise Server 9 (x86), v7.9.0-108.sles9 Fixes Resolved issue where hprsm rebuild process would not reference outdated RPM tag. ******************************** hprsm-7.9.0-108.sles9.x86_64.rpm - HP Lights-Out Drivers and Agents for SUSE LINUX Enterprise Server 9 (AMD64/EM64T), v7.9.0-108.sles9 Fixes Resolved issue where hprsm rebuild process would not reference outdated RPM tag. ******************************** hpmouse-1.1.1-41.noarch.rpm - HP Version Control Agent for Linux, v1.1.1-41 Enhancements Added code to accept any variance of ‘YesEwill work for HPMOUSESILENT. ******************************** hp-pel-1.0.1-3.sles9.linux.rpm - HP Linux ProLiant Essentials Licensing for SUSE Linux Enterprise Server 9, v1.0.1-3.sles9 Enhancements Added support for latest distribution updates, which allows the user to run the package on the latest Operating System versions. ******************************** hp-vt-1.1.1-3.sles9.linux.rpm - HP Virus Throttle for SUSE Linux Enterprise Server 9, v1.1.1-3.sles9 Enhancements Added support for latest distribution updates, which allows the user to run the package on the latest Operating System versions. ******************************** cmanic-7.9.0-5.sles9.linux.rpm - HP NIC Agents for SUSE Linux Enterprise Server 9, v7.9.0-5.sles9 Enhancements This software now supports the NC360m and NC364m NICs. ******************************** cpqacuxe-7.85-18.linux.rpm - HP Array Configuration Utility for Linux, v7.85-18 Enhancements Enabled drive write cache for all SAS controllers ******************************** hpacucli-7.85-18.linux.rpm - HP Array Configuration Utility CLI for Linux, v7.85-18 Enhancements Enabled drive write cache for all SAS controllers ******************************** hpadu-7.85-16.linux.rpm - HP Array Diagnostics Utility for Linux, v7.85-16 Enhancements Added support for MSA 2000s (MSA 2060s and MSA 2070s) Controller. ******************************** hpdiags-7.9.0-105.linux.i386.rpm - HP Insight Diagnostics Online Edition for Linux, v7.9.0-105 Enhancements Linux Online Support for SmartStart 7.90. ******************************** fibreutils-2.3-4.linux.i386.rpm - Fibre Channel Utilities for HP StorageWorks FCA2214/FCA2214DC FC HBA for Linux (x86), v2.3-4 Fixes Fixed floating point exception on x86 architectures with scsi_info Fixed date string in hp_system_info ******************************** fibreutils-2.3-4.linux.x86_64.rpm - Fibre Channel Utilities for HP StorageWorks FCA2214/FCA2214DC FC HBA for Linux (AMD64/EM64T), v2.3-4 Fixes Fixed floating point exception on x86 architectures with scsi_info Fixed date string in hp_system_info ******************************** Copyright 2003-2007 Hewlett-Packard Development Company, L.P.