320411 System Speaker, Continuous Tone Test User could not hear test tone This test failed as a result of the the speaker not being recognized by diagnostics. To have passed, the system should have a speaker installed, and a tone should have been heard. A failure of this test may indicate that either no speaker is present, or a replacement speaker needs to be obtained.
320305 System Speaker, Random Tone Test User could not hear test tone This test failed as a result of the the speaker not being recognized by diagnostics. To have passed, the system should have a speaker installed, and a tone should have been heard. A failure of this test may indicate that either no speaker is present, or a replacement speaker needs to be obtained.
010157 CPU, Floating Point Test Zero/infinity boundary This test performs boundary checking. It checks for zero, infinity, and illegal instruction conditions. To have failed this test, the processor failed the boundary test of multiplying and dividing with zero and infinity. A failing processor (CPU) may cause problems running applications. This test could have failed due to excessive heat around the processor (CPU). Ensure that there is proper ventilation and cooling for the server, and that the front and rear of the server has appropriate clearance for proper cooling. Ensure that the heat-sink on the processors (CPU`s) are attached correctly (do not remove them). Check diagnostics for temperature inside the server, and also check the Integrated Management Log for any heat-related events. Re-run this test. If the test fails again, a replacement should be obtained. The appropriate processor (CPU) to be replaced should be noted in the error message itself. Please call HP Warranty Support for assistance (number can be found in "Help").
010158 CPU, Floating Point Test Pentium floating point bug This test checks for the Pentium Divide Bug. To have failed, the processor (CPU) has detected the floating point divide Pentium bug. As a result, the processor (CPU) may cause problems running applications. A replacement processor (CPU) should be obtained. The appropriate processor (CPU) to be replaced should be noted in the error message itself. Please call HP Warranty Support for assistance (number can be found in "Help").
010133 CPU, Floating Point Test Coprocessor geometric test err This test performs a geometric series test. To have failed this test, the processor (CPU) geometric series test provided results that were out of range. A failing processor (CPU) may cause problems running applications. This test could have failed due to excessive heat around the processor (CPU). Ensure that there is proper ventilation and cooling for the server, and that the front and rear of the server has appropriate clearance for proper cooling. Ensure that the heat-sink on the processors (CPU`s) are attached correctly (do not remove them). Check diagnostics for temperature inside the server, and also check the Integrated Management Log for any heat-related events. Re-run this test. If the test fails again, a replacement processor (CPU) should be obtained. The appropriate processor (CPU) to be replaced should be noted in the error message itself. Please call HP Warranty Support for assistance (number can be found in "Help").
010521 CPU, Refresh Timer Test Refresh count out of range This test verifies that the refresh timer, located within the memory controller, is operational by polling the refresh detect bit at I/O port 61h. The refresh timer generates the periodic refresh request signal that triggers the DRAM refresh logic to become bus master. If this test has failed, the refresh counter is either too fast or too slow. This may cause instabilities in the operating system due to overheated RAM or intermittent RAM data loss. It is recommended that the board that the memory controller chip is placed on should be replaced. Please call HP Warranty Support for assistance (number can be found in "Help").
010159 CPU, Register Test Register integer math This test manipulates all the general registers through arithmetic operations. The arithmetic operations are done with all combinations of the listed registers. Any failure may indicate the processor (CPU) may not fully function and may give incorrect results in applications. This test could have failed due to excessive heat around the processor (CPU). Ensure that there is proper ventilation and cooling for the server, and that the front and rear of the server has appropriate clearance for proper cooling. Ensure that the heat-sink on the processors (CPU`s) are attached correctly (do not remove them). Check diagnostics for temperature inside the server, and also check the Integrated Management Log for any heat-related events. Re-run this test. If the test fails again, a replacement processor (CPU) should be obtained. The appropriate processor (CPU) to be replaced should be noted in the error message itself. Please call HP Warranty Support for assistance (number can be found in "Help").
011225 CPU, Speed Test Cpu speed out of range This test verifies the CPU is running at the correct clock speed. The test determines the clock speed at which the CPU is running and compares that speed to the expected speed. The test takes three samples and averages them out. The actual speed is calculated using the Time Stamp Counter Model Specific Register. The expected speed used in the comparison is read from the SMBios. To have passed, the processor (CPU) should have returned an actual speed value matching the processor`s (CPU`s) rated speed as provided in the Time Stamp Counter Model Specific Register. a replacement processor (CPU) should be obtained. The appropriate processor (CPU) to be replaced should be noted in the error message itself. Please call HP Warranty Support for assistance (number can be found in "Help").
011226 CPU, Speed Test Unable to select/run processor Please call HP Warranty Support for assistance (number can be found in "Help").
010160 CPU, Real Time Clock Test Unable to update CMOS time This test ensures that the Real Time Clock updates the system`s CMOS time. Any failure could result in failures for time-dependent applications. To have passed, the Real Time Clock should have updated the system`s CMOS time accurately. It is recommended that the board on which the CMOS is located should be replaced. Please call HP Warranty Support for assistance (number can be found in "Help").
010134 CPU, MMX Register Test MMX hardware not present This test verifies the presence of MMX instructions on Intel-based Pentium II and later processors (CPU`s). For this test to pass, the processor (CPU) must be a Pentium II or later processor (CPU) with the MMX instructions. If the processor (CPU) under test is a Pentium II or later processor (CPU), this is indicative of a processor (CPU) failure, and a replacement processor (CPU) should be obtained. The appropriate processor (CPU) to be replaced should be noted in the error message itself. Please call HP Warranty Support for assistance (number can be found in "Help").
010161 CPU, MMX Register Test MMX add instruction This error indicates that an MMX add instruction failed. This is indicative of a processor (CPU) failure, and a replacement processor (CPU) should be obtained. The appropriate processor (CPU) to be replaced should be noted in the error message itself. Please call HP Warranty Support for assistance (number can be found in "Help").
010162 CPU, MMX Register Test MMX subtract instruction This error indicates that an MMX subtract instruction failed. This is indicative of a processor (CPU) failure, and a replacement processor (CPU) should be obtained. The appropriate processor (CPU) to be replaced should be noted in the error message itself. Please call HP Warranty Support for assistance (number can be found in "Help").
010163 CPU, MMX Register Test MMX multiply instruction This error indicates that an MMX multiply instruction failed. This is indicative of a processor (CPU) failure, and a replacement processor (CPU) should be obtained. The appropriate processor (CPU) to be replaced should be noted in the error message itself. Please call HP Warranty Support for assistance (number can be found in "Help").
010164 CPU, MMX Register Test MMX logical instruction This error indicates that an MMX logical instruction failed. This is indicative of a processor (CPU) failure, and a replacement processor (CPU) should be obtained. The appropriate processor (CPU) to be replaced should be noted in the error message itself. Please call HP Warranty Support for assistance (number can be found in "Help").
010165 CPU, MMX Register Test MMX shift instruction This error indicates that an MMX shift instruction failed. This is indicative of a processor (CPU) failure, and a replacement processor (CPU) should be obtained. The appropriate processor (CPU) to be replaced should be noted in the error message itself. Please call HP Warranty Support for assistance (number can be found in "Help").
010167 CPU, MMX Register Test MMX pack/unpack This error indicates that an MMX pack/unpack instruction failed. This is indicative of a processor (CPU) failure, and a replacement processor (CPU) should be obtained. The appropriate processor (CPU) to be replaced should be noted in the error message itself. Please call HP Warranty Support for assistance (number can be found in "Help").
010168 CPU, MMX Register Test MMX compare instruction This error indicates that an MMX compare instruction failed. This is indicative of a processor (CPU) failure, and a replacement processor (CPU) should be obtained. The appropriate processor (CPU) to be replaced should be noted in the error message itself. Please call HP Warranty Support for assistance (number can be found in "Help").
010143 CPU, MMX Register Test Unable to select/run processor Please call HP Warranty Support for assistance (number can be found in "Help").
010169 CPU, MMX Register Test MMX move quad instruction This error indicates that an MMX move quad instruction failed. This is indicative of a processor (CPU) failure, and a replacement processor (CPU) should be obtained. The appropriate processor (CPU) to be replaced should be noted in the error message itself. Please call HP Warranty Support for assistance (number can be found in "Help").
010172 CPU, MMX Register Test SSE instruction This error indicates that an SSE instruction failed. This is indicative of a processor (CPU) failure, and a replacement processor (CPU) should be obtained. The appropriate processor (CPU) to be replaced should be noted in the error message itself. Please call HP Warranty Support for assistance (number can be found in "Help").
010170 CPU, Stress Test Stress integer math This test is responsible for stress testing CPU`s. It doesn`t test a specific individual feature of the CPU. Instead, it executes a massive number of mathematical operations for an extended period of time. This is intended to help detect problems that manifest over tim, including thermal related issues. Running this test with the appropriate parameters will utilize the processors (CPU`s) at 95-100 percent capacity, with some losses due to context switching and thread monitoring. This test will also catch more intermittent problems than the other tests. This test could have failed due to excessive heat around the processor (CPU). Ensure that there is proper ventilation and cooling for the server, and that the front and rear of the server has appropriate clearance for proper cooling. Ensure that the heat-sink on the processors (CPU`s) are attached correctly (do not remove them). Check diagnostics for temperature inside the server, and also check the Integrated Management Log for any heat-related events. Re-run this test. A replacement processor (CPU) should be obtained if this test fails. The appropriate processor (CPU) to be replaced should be noted in the error message itself. Please call HP Warranty Support for assistance (number can be found in "Help").
010171 CPU, Stress Test Stress floating point This test is responsible for stress testing CPU`s. It doesn`t test a specific individual feature of the CPU. Instead, it executes a massive number of mathematical operations for an extended period of time. This is intended to help detect problems that manifest over tim, including thermal related issues. Running this test with the appropriate parameters will utilize the processors (CPU`s) at 95-100 percent capacity, with some losses due to context switching and thread monitoring. This test will also catch more intermittent problems than the other tests. This test could have failed due to excessive heat around the processor (CPU). Ensure that there is proper ventilation and cooling for the server, and that the front and rear of the server has appropriate clearance for proper cooling. Ensure that the heat-sink on the processors (CPU`s) are attached correctly (do not remove them). Check diagnostics for temperature inside the server, and also check the Integrated Management Log for any heat-related events. Re-run this test. A replacement processor (CPU) should be obtained if this test fails. The appropriate processor (CPU) to be replaced should be noted in the error message itself. Please call HP Warranty Support for assistance (number can be found in "Help").
013203 CPU, Stress Test Unable to select/run processor Please call HP Warranty Support for assistance (number can be found in "Help").
061101 Ide Diskette, Sequential Read Test Media not present in drive This test failed as a result of the diskette drive not having a formatted diskette present in the diskette drive. Correct the error condition by placing media into the diskette drive, and re-run this test. If there was media present in the drive when the test was last run, then the drive requires replacement. Please call HP Warranty Support for assistance (number can be found in "Help"). More information on this error and troubleshooting steps can be obtained from the support web site, or from referencing the error message code in the Troubleshooting Guide that accompanied your system.
061102 Ide Diskette, Sequential Read Test Could not seek block Replace and/or format drive media. If this does not correct the problem, the drive may require replacement. Please call HP Warranty Support for assistance (number can be found in "Help"). More information on this error and troubleshooting steps can be obtained from the HP support web site, or from referencing the error message code in the Troubleshooting Guide that accompanied your system.
061103 Ide Diskette, Sequential Read Test Could not read block Replace and/or format drive media. If this does not correct the problem, the drive may require replacement. Please call HP Warranty Support for assistance (number can be found in "Help"). More information on this error and troubleshooting steps can be obtained from the HP support web site, or from referencing the error message code in the Troubleshooting Guide that accompanied your system.
061201 Ide Diskette, Butterfly Read Test Media not present in drive This test failed as a result of the diskette drive not having a formatted diskette present in the diskette drive. Correct the error condition by placing media into the diskette drive, and re-run this test. If there was media present in the drive when the test was last run, then the drive requires replacement. Please call HP Warranty Support for assistance (number can be found in "Help"). More information on this error and troubleshooting steps can be obtained from the support web site, or from referencing the error message code in the Troubleshooting Guide that accompanied your system.
061202 Ide Diskette, Butterfly Read Test Could not seek block Replace and/or format drive media. If this does not correct the problem, the drive may require replacement. Please call HP Warranty Support for assistance (number can be found in "Help"). More information on this error and troubleshooting steps can be obtained from the HP support web site, or from referencing the error message code in the Troubleshooting Guide that accompanied your system.
061203 Ide Diskette, Butterfly Read Test Could not read block Replace and/or format drive media. If this does not correct the problem, the drive may require replacement. Please call HP Warranty Support for assistance (number can be found in "Help"). More information on this error and troubleshooting steps can be obtained from the HP support web site, or from referencing the error message code in the Troubleshooting Guide that accompanied your system.
061301 Ide Diskette, Random Read Test Media not present in drive This test failed as a result of the diskette drive not having a formatted diskette present in the diskette drive. Correct the error condition by placing media into the diskette drive, and re-run this test. If there was media present in the drive when the test was last run, then the drive requires replacement. Please call HP Warranty Support for assistance (number can be found in "Help"). More information on this error and troubleshooting steps can be obtained from the support web site, or from referencing the error message code in the Troubleshooting Guide that accompanied your system.
061302 Ide Diskette, Random Read Test Could not seek block Replace and/or format drive media. If this does not correct the problem, the drive may require replacement. Please call HP Warranty Support for assistance (number can be found in "Help"). More information on this error and troubleshooting steps can be obtained from the HP support web site, or from referencing the error message code in the Troubleshooting Guide that accompanied your system.
061303 Ide Diskette, Random Read Test Could not read block Replace and/or format drive media. If this does not correct the problem, the drive may require replacement. Please call HP Warranty Support for assistance (number can be found in "Help"). More information on this error and troubleshooting steps can be obtained from the HP support web site, or from referencing the error message code in the Troubleshooting Guide that accompanied your system.
061501 Ide Diskette, Sequential Seek Test Media not present in drive This test failed as a result of the diskette drive not having a formatted diskette present in the diskette drive. Correct the error condition by placing media into the diskette drive, and re-run this test. If there was media present in the drive when the test was last run, then the drive requires replacement. Please call HP Warranty Support for assistance (number can be found in "Help"). More information on this error and troubleshooting steps can be obtained from the support web site, or from referencing the error message code in the Troubleshooting Guide that accompanied your system.
061502 Ide Diskette, Sequential Seek Test Could not seek block Replace and/or format drive media. If this does not correct the problem, the drive may require replacement. Please call HP Warranty Support for assistance (number can be found in "Help"). More information on this error and troubleshooting steps can be obtained from the HP support web site, or from referencing the error message code in the Troubleshooting Guide that accompanied your system.
061601 Ide Diskette, Butterfly Seek Test Media not present in drive This test failed as a result of the diskette drive not having a formatted diskette present in the diskette drive. Correct the error condition by placing media into the diskette drive, and re-run this test. If there was media present in the drive when the test was last run, then the drive requires replacement. Please call HP Warranty Support for assistance (number can be found in "Help"). More information on this error and troubleshooting steps can be obtained from the support web site, or from referencing the error message code in the Troubleshooting Guide that accompanied your system.
061602 Ide Diskette, Butterfly Seek Test Could not seek block Replace and/or format drive media. If this does not correct the problem, the drive may require replacement. Please call HP Warranty Support for assistance (number can be found in "Help"). More information on this error and troubleshooting steps can be obtained from the HP support web site, or from referencing the error message code in the Troubleshooting Guide that accompanied your system.
061701 Ide Diskette, Random Seek Test Media not present in drive This test failed as a result of the diskette drive not having a formatted diskette present in the diskette drive. Correct the error condition by placing media into the diskette drive, and re-run this test. If there was media present in the drive when the test was last run, then the drive requires replacement. Please call HP Warranty Support for assistance (number can be found in "Help"). More information on this error and troubleshooting steps can be obtained from the support web site, or from referencing the error message code in the Troubleshooting Guide that accompanied your system.
061702 Ide Diskette, Random Seek Test Could not seek block Replace and/or format drive media. If this does not correct the problem, the drive may require replacement. Please call HP Warranty Support for assistance (number can be found in "Help"). More information on this error and troubleshooting steps can be obtained from the HP support web site, or from referencing the error message code in the Troubleshooting Guide that accompanied your system.
061801 Ide Diskette, Sequential RWRC Test Media not present in drive This test failed as a result of the diskette drive not having a formatted diskette present in the diskette drive. Correct the error condition by placing media into the diskette drive, and re-run this test. If there was media present in the drive when the test was last run, then the drive requires replacement. Please call HP Warranty Support for assistance (number can be found in "Help"). More information on this error and troubleshooting steps can be obtained from the support web site, or from referencing the error message code in the Troubleshooting Guide that accompanied your system.
061802 Ide Diskette, Sequential RWRC Test Could not seek block Replace and/or format drive media. If this does not correct the problem, the drive may require replacement. Please call HP Warranty Support for assistance (number can be found in "Help"). More information on this error and troubleshooting steps can be obtained from the HP support web site, or from referencing the error message code in the Troubleshooting Guide that accompanied your system.
061803 Ide Diskette, Sequential RWRC Test Could not read block Replace and/or format drive media. If this does not correct the problem, the drive may require replacement. Please call HP Warranty Support for assistance (number can be found in "Help"). More information on this error and troubleshooting steps can be obtained from the HP support web site, or from referencing the error message code in the Troubleshooting Guide that accompanied your system.
061804 Ide Diskette, Sequential RWRC Test Could not write block Replace and/or format drive media. If this does not correct the problem, the drive may require replacement. Please call HP Warranty Support for assistance (number can be found in "Help"). More information on this error and troubleshooting steps can be obtained from the HP support web site, or from referencing the error message code in the Troubleshooting Guide that accompanied your system.
061901 Ide Diskette, Butterfly RWRC Test Media not present in drive This test failed as a result of the diskette drive not having a formatted diskette present in the diskette drive. Correct the error condition by placing media into the diskette drive, and re-run this test. If there was media present in the drive when the test was last run, then the drive requires replacement. Please call HP Warranty Support for assistance (number can be found in "Help"). More information on this error and troubleshooting steps can be obtained from the support web site, or from referencing the error message code in the Troubleshooting Guide that accompanied your system.
061902 Ide Diskette, Butterfly RWRC Test Could not seek block Replace and/or format drive media. If this does not correct the problem, the drive may require replacement. Please call HP Warranty Support for assistance (number can be found in "Help"). More information on this error and troubleshooting steps can be obtained from the HP support web site, or from referencing the error message code in the Troubleshooting Guide that accompanied your system.
061903 Ide Diskette, Butterfly RWRC Test Could not read block Replace and/or format drive media. If this does not correct the problem, the drive may require replacement. Please call HP Warranty Support for assistance (number can be found in "Help"). More information on this error and troubleshooting steps can be obtained from the HP support web site, or from referencing the error message code in the Troubleshooting Guide that accompanied your system.
061904 Ide Diskette, Butterfly RWRC Test Could not write block Replace and/or format drive media. If this does not correct the problem, the drive may require replacement. Please call HP Warranty Support for assistance (number can be found in "Help"). More information on this error and troubleshooting steps can be obtained from the HP support web site, or from referencing the error message code in the Troubleshooting Guide that accompanied your system.
062001 Ide Diskette, Random RWRC Test Media not present in drive This test failed as a result of the diskette drive not having a formatted diskette present in the diskette drive. Correct the error condition by placing media into the diskette drive, and re-run this test. If there was media present in the drive when the test was last run, then the drive requires replacement. Please call HP Warranty Support for assistance (number can be found in "Help"). More information on this error and troubleshooting steps can be obtained from the support web site, or from referencing the error message code in the Troubleshooting Guide that accompanied your system.
062002 Ide Diskette, Random RWRC Test Could not seek block Replace and/or format drive media. If this does not correct the problem, the drive may require replacement. Please call HP Warranty Support for assistance (number can be found in "Help"). More information on this error and troubleshooting steps can be obtained from the HP support web site, or from referencing the error message code in the Troubleshooting Guide that accompanied your system.
062003 Ide Diskette, Random RWRC Test Could not read block Replace and/or format drive media. If this does not correct the problem, the drive may require replacement. Please call HP Warranty Support for assistance (number can be found in "Help"). More information on this error and troubleshooting steps can be obtained from the HP support web site, or from referencing the error message code in the Troubleshooting Guide that accompanied your system.
062004 Ide Diskette, Random RWRC Test Could not write block Replace and/or format drive media. If this does not correct the problem, the drive may require replacement. Please call HP Warranty Support for assistance (number can be found in "Help"). More information on this error and troubleshooting steps can be obtained from the HP support web site, or from referencing the error message code in the Troubleshooting Guide that accompanied your system.
062101 Ide Diskette, Floppy Remove Test Media not present in drive This test failed as a result of the diskette drive not having a formatted diskette present in the diskette drive. Correct the error condition by placing media into the diskette drive, and re-run this test. If there was media present in the drive when the test was last run, then the drive requires replacement. Please call HP Warranty Support for assistance (number can be found in "Help"). More information on this error and troubleshooting steps can be obtained from the support web site, or from referencing the error message code in the Troubleshooting Guide that accompanied your system.
062102 Ide Diskette, Floppy Remove Test Disk change not detected Drive requires replacement. Please call HP Warranty Support for assistance (number can be found in "Help"). More information on this error and troubleshooting steps can be obtained from the HP support web site, or from referencing the error message code in the Troubleshooting Guide that accompanied your system.
062201 Ide Diskette, Floppy Write Protect Test Media not present in drive This test failed as a result of the diskette drive not having a formatted diskette present in the diskette drive. Correct the error condition by placing media into the diskette drive, and re-run this test. If there was media present in the drive when the test was last run, then the drive requires replacement. Please call HP Warranty Support for assistance (number can be found in "Help"). More information on this error and troubleshooting steps can be obtained from the support web site, or from referencing the error message code in the Troubleshooting Guide that accompanied your system.
062202 Ide Diskette, Floppy Write Protect Test Write protect media not found Drive requires replacement. Please call HP Warranty Support for assistance (number can be found in "Help"). More information on this error and troubleshooting steps can be obtained from the HP support web site, or from referencing the error message code in the Troubleshooting Guide that accompanied your system.
174301 Ide Disk, Sequential Read Test Could not seek block Drive requires replacement. Please call HP Warranty Support for assistance (number can be found in "Help"). More information on this error and troubleshooting steps can be obtained from the HP support web site, or from referencing the error message code in the Troubleshooting Guide that accompanied your system.
174302 Ide Disk, Sequential Read Test Could not read block Drive requires replacement. Please call HP Warranty Support for assistance (number can be found in "Help"). More information on this error and troubleshooting steps can be obtained from the HP support web site, or from referencing the error message code in the Troubleshooting Guide that accompanied your system.
174401 Ide Disk, Butterfly Read Test Could not seek block Drive requires replacement. Please call HP Warranty Support for assistance (number can be found in "Help"). More information on this error and troubleshooting steps can be obtained from the HP support web site, or from referencing the error message code in the Troubleshooting Guide that accompanied your system.
174402 Ide Disk, Butterfly Read Test Could not read block Drive requires replacement. Please call HP Warranty Support for assistance (number can be found in "Help"). More information on this error and troubleshooting steps can be obtained from the HP support web site, or from referencing the error message code in the Troubleshooting Guide that accompanied your system.
174501 Ide Disk, Random Read Test Could not seek block Drive requires replacement. Please call HP Warranty Support for assistance (number can be found in "Help"). More information on this error and troubleshooting steps can be obtained from the HP support web site, or from referencing the error message code in the Troubleshooting Guide that accompanied your system.
174502 Ide Disk, Random Read Test Could not read block Drive requires replacement. Please call HP Warranty Support for assistance (number can be found in "Help"). More information on this error and troubleshooting steps can be obtained from the HP support web site, or from referencing the error message code in the Troubleshooting Guide that accompanied your system.
174601 Ide Disk, Sequential Seek Test Could not seek block Drive requires replacement. Please call HP Warranty Support for assistance (number can be found in "Help"). More information on this error and troubleshooting steps can be obtained from the HP support web site, or from referencing the error message code in the Troubleshooting Guide that accompanied your system.
174701 Ide Disk, Butterfly Seek Test Could not seek block Drive requires replacement. Please call HP Warranty Support for assistance (number can be found in "Help"). More information on this error and troubleshooting steps can be obtained from the HP support web site, or from referencing the error message code in the Troubleshooting Guide that accompanied your system.
174801 Ide Disk, Random Seek Test Could not seek block Drive requires replacement. Please call HP Warranty Support for assistance (number can be found in "Help"). More information on this error and troubleshooting steps can be obtained from the HP support web site, or from referencing the error message code in the Troubleshooting Guide that accompanied your system.
174901 Ide Disk, Sequential RWRC Test Could not seek block Drive requires replacement. Please call HP Warranty Support for assistance (number can be found in "Help"). More information on this error and troubleshooting steps can be obtained from the HP support web site, or from referencing the error message code in the Troubleshooting Guide that accompanied your system.
174902 Ide Disk, Sequential RWRC Test Could not read block Drive requires replacement. Please call HP Warranty Support for assistance (number can be found in "Help"). More information on this error and troubleshooting steps can be obtained from the HP support web site, or from referencing the error message code in the Troubleshooting Guide that accompanied your system.
174903 Ide Disk, Sequential RWRC Test Could not write block Drive requires replacement. Please call HP Warranty Support for assistance (number can be found in "Help"). More information on this error and troubleshooting steps can be obtained from the HP support web site, or from referencing the error message code in the Troubleshooting Guide that accompanied your system.
175001 Ide Disk, Butterfly RWRC Test Could not seek block Drive requires replacement. Please call HP Warranty Support for assistance (number can be found in "Help"). More information on this error and troubleshooting steps can be obtained from the HP support web site, or from referencing the error message code in the Troubleshooting Guide that accompanied your system.
175002 Ide Disk, Butterfly RWRC Test Could not read block Drive requires replacement. Please call HP Warranty Support for assistance (number can be found in "Help"). More information on this error and troubleshooting steps can be obtained from the HP support web site, or from referencing the error message code in the Troubleshooting Guide that accompanied your system.
175003 Ide Disk, Butterfly RWRC Test Could not write block Drive requires replacement. Please call HP Warranty Support for assistance (number can be found in "Help"). More information on this error and troubleshooting steps can be obtained from the HP support web site, or from referencing the error message code in the Troubleshooting Guide that accompanied your system.
175101 Ide Disk, Random RWRC Test Could not seek block Drive requires replacement. Please call HP Warranty Support for assistance (number can be found in "Help"). More information on this error and troubleshooting steps can be obtained from the HP support web site, or from referencing the error message code in the Troubleshooting Guide that accompanied your system.
175102 Ide Disk, Random RWRC Test Could not read block Drive requires replacement. Please call HP Warranty Support for assistance (number can be found in "Help"). More information on this error and troubleshooting steps can be obtained from the HP support web site, or from referencing the error message code in the Troubleshooting Guide that accompanied your system.
175103 Ide Disk, Random RWRC Test Could not write block Drive requires replacement. Please call HP Warranty Support for assistance (number can be found in "Help"). More information on this error and troubleshooting steps can be obtained from the HP support web site, or from referencing the error message code in the Troubleshooting Guide that accompanied your system.
175201 Ide Disk, Self Test Quick Could not get new status The drive should be replace as soon as possible. Please call HP Warranty Support for assistance (number can be found in "Help"). More information on this error and troubleshooting steps can be obtained from the support web site, or from referencing the error message code in the Troubleshooting Guide that accompanied your system.
175202 Ide Disk, Self Test Quick Could not init SMART values The drive should be replace as soon as possible. Please call HP Warranty Support for assistance (number can be found in "Help"). More information on this error and troubleshooting steps can be obtained from the support web site, or from referencing the error message code in the Troubleshooting Guide that accompanied your system.
175203 Ide Disk, Self Test Quick Drive does not support SMART This test is not applicable for this drive.
175205 Ide Disk, Self Test Quick Could not send quick command The drive should be replace as soon as possible. Please call HP Warranty Support for assistance (number can be found in "Help"). More information on this error and troubleshooting steps can be obtained from the support web site, or from referencing the error message code in the Troubleshooting Guide that accompanied your system.
175301 Ide Disk, Self Test Extended Could not get new status The drive should be replace as soon as possible. Please call HP Warranty Support for assistance (number can be found in "Help"). More information on this error and troubleshooting steps can be obtained from the support web site, or from referencing the error message code in the Troubleshooting Guide that accompanied your system.
175302 Ide Disk, Self Test Extended Could not init SMART values The drive should be replace as soon as possible. Please call HP Warranty Support for assistance (number can be found in "Help"). More information on this error and troubleshooting steps can be obtained from the support web site, or from referencing the error message code in the Troubleshooting Guide that accompanied your system.
175303 Ide Disk, Self Test Extended Drive does not support SMART This test is not applicable for this drive.
175304 Ide Disk, Self Test Extended Extended command unsupported The drive should be replace as soon as possible. Please call HP Warranty Support for assistance (number can be found in "Help"). More information on this error and troubleshooting steps can be obtained from the support web site, or from referencing the error message code in the Troubleshooting Guide that accompanied your system.
175401 Ide Disk, Reset Test Device could not be reset Drive requires replacement. Please call HP Warranty Support for assistance (number can be found in "Help"). More information on this error and troubleshooting steps can be obtained from the HP support web site, or from referencing the error message code in the Troubleshooting Guide that accompanied your system.
181201 Ide CDROM, Sequential Read Test Media not present in drive This test failed as a result of the diskette drive not having a formatted diskette present in the diskette drive. Correct the error condition by placing media into the diskette drive, and re-run this test. If there was media present in the drive when the test was last run, then the drive requires replacement. Please call HP Warranty Support for assistance (number can be found in "Help"). More information on this error and troubleshooting steps can be obtained from the support web site, or from referencing the error message code in the Troubleshooting Guide that accompanied your system.
181202 Ide CDROM, Sequential Read Test Could not seek block Drive requires replacement. Please call HP Warranty Support for assistance (number can be found in "Help"). More information on this error and troubleshooting steps can be obtained from the HP support web site, or from referencing the error message code in the Troubleshooting Guide that accompanied your system.
181203 Ide CDROM, Sequential Read Test Could not read block Drive requires replacement. Please call HP Warranty Support for assistance (number can be found in "Help"). More information on this error and troubleshooting steps can be obtained from the HP support web site, or from referencing the error message code in the Troubleshooting Guide that accompanied your system.
181301 Ide CDROM, Butterfly Read Test Media not present in drive This test failed as a result of the diskette drive not having a formatted diskette present in the diskette drive. Correct the error condition by placing media into the diskette drive, and re-run this test. If there was media present in the drive when the test was last run, then the drive requires replacement. Please call HP Warranty Support for assistance (number can be found in "Help"). More information on this error and troubleshooting steps can be obtained from the support web site, or from referencing the error message code in the Troubleshooting Guide that accompanied your system.
181302 Ide CDROM, Butterfly Read Test Could not seek block Drive requires replacement. Please call HP Warranty Support for assistance (number can be found in "Help"). More information on this error and troubleshooting steps can be obtained from the HP support web site, or from referencing the error message code in the Troubleshooting Guide that accompanied your system.
181303 Ide CDROM, Butterfly Read Test Could not read block Drive requires replacement. Please call HP Warranty Support for assistance (number can be found in "Help"). More information on this error and troubleshooting steps can be obtained from the HP support web site, or from referencing the error message code in the Troubleshooting Guide that accompanied your system.
181401 Ide CDROM, Random Read Test Media not present in drive This test failed as a result of the diskette drive not having a formatted diskette present in the diskette drive. Correct the error condition by placing media into the diskette drive, and re-run this test. If there was media present in the drive when the test was last run, then the drive requires replacement. Please call HP Warranty Support for assistance (number can be found in "Help"). More information on this error and troubleshooting steps can be obtained from the support web site, or from referencing the error message code in the Troubleshooting Guide that accompanied your system.
181402 Ide CDROM, Random Read Test Could not seek block Drive requires replacement. Please call HP Warranty Support for assistance (number can be found in "Help"). More information on this error and troubleshooting steps can be obtained from the HP support web site, or from referencing the error message code in the Troubleshooting Guide that accompanied your system.
181403 Ide CDROM, Random Read Test Could not read block Drive requires replacement. Please call HP Warranty Support for assistance (number can be found in "Help"). More information on this error and troubleshooting steps can be obtained from the HP support web site, or from referencing the error message code in the Troubleshooting Guide that accompanied your system.
181501 Ide CDROM, Sequential Seek Test Media not present in drive This test failed as a result of the diskette drive not having a formatted diskette present in the diskette drive. Correct the error condition by placing media into the diskette drive, and re-run this test. If there was media present in the drive when the test was last run, then the drive requires replacement. Please call HP Warranty Support for assistance (number can be found in "Help"). More information on this error and troubleshooting steps can be obtained from the support web site, or from referencing the error message code in the Troubleshooting Guide that accompanied your system.
181502 Ide CDROM, Sequential Seek Test Could not seek block Drive requires replacement. Please call HP Warranty Support for assistance (number can be found in "Help"). More information on this error and troubleshooting steps can be obtained from the HP support web site, or from referencing the error message code in the Troubleshooting Guide that accompanied your system.
181601 Ide CDROM, Butterfly Seek Test Media not present in drive This test failed as a result of the diskette drive not having a formatted diskette present in the diskette drive. Correct the error condition by placing media into the diskette drive, and re-run this test. If there was media present in the drive when the test was last run, then the drive requires replacement. Please call HP Warranty Support for assistance (number can be found in "Help"). More information on this error and troubleshooting steps can be obtained from the support web site, or from referencing the error message code in the Troubleshooting Guide that accompanied your system.
181602 Ide CDROM, Butterfly Seek Test Could not seek block Drive requires replacement. Please call HP Warranty Support for assistance (number can be found in "Help"). More information on this error and troubleshooting steps can be obtained from the HP support web site, or from referencing the error message code in the Troubleshooting Guide that accompanied your system.
181701 Ide CDROM, Random Seek Test Media not present in drive This test failed as a result of the diskette drive not having a formatted diskette present in the diskette drive. Correct the error condition by placing media into the diskette drive, and re-run this test. If there was media present in the drive when the test was last run, then the drive requires replacement. Please call HP Warranty Support for assistance (number can be found in "Help"). More information on this error and troubleshooting steps can be obtained from the support web site, or from referencing the error message code in the Troubleshooting Guide that accompanied your system.
181702 Ide CDROM, Random Seek Test Could not seek block Drive requires replacement. Please call HP Warranty Support for assistance (number can be found in "Help"). More information on this error and troubleshooting steps can be obtained from the HP support web site, or from referencing the error message code in the Troubleshooting Guide that accompanied your system.
181801 Ide CDROM, Reset Test Device could not be reset Drive requires replacement. Please call HP Warranty Support for assistance (number can be found in "Help"). More information on this error and troubleshooting steps can be obtained from the HP support web site, or from referencing the error message code in the Troubleshooting Guide that accompanied your system.
181901 Ide CDROM, Tray Test Tray could not be ejected Drive requires replacement. Please call HP Warranty Support for assistance (number can be found in "Help"). More information on this error and troubleshooting steps can be obtained from the HP support web site, or from referencing the error message code in the Troubleshooting Guide that accompanied your system.
030311 Keyboard Device, LED Test Keyboard LED This test failed as a result of the left mouse button not registering a depression. To have passed, the system should have detected the depression of the left mouse button. Check the mouse connector and ensure that it was seated properly. If the mouse has a P/S2 connector, ensure that all pins are present. Ensure that no pins are bent on the connector. A failure of this test may indicate that a replacement mouse needs to be obtained. A spare part number for the mouse will be located on the bottom, near the "ball." More information on this error can be obtained from the support web site, or from referencing the error message code in the Troubleshooting Guide that accompanied your system. Please call HP Warranty Support for assistance.
032024 Keyboard Device, LED Test Keypress failed This test failed as a result of the right mouse button not registering a depression. To have passed, the system should have detected the depression of the right mouse button. Check the mouse connector and ensure that it was seated properly. If the mouse has a P/S2 connector, ensure that all pins are present. Ensure that no pins are bent on the connector. A failure of this test may indicate that a replacement mouse needs to be obtained. A spare part number for the mouse will be located on the bottom, near the "ball." More information on this error can be obtained from the support web site, or from referencing the error message code in the Troubleshooting Guide that accompanied your system. Please call HP Warranty Support for assistance.
030299 Keyboard Device, LED Test Invalid Scan Code found This test failed as a result of the middle mouse button not registering a depression. To have passed, the system should have detected the depression of the middle mouse button. Check the mouse connector and ensure that it was seated properly. If the mouse has a P/S2 connector, ensure that all pins are present. Ensure that no pins are bent on the connector. A failure of this test may indicate that a replacement mouse needs to be obtained. A spare part number for the mouse will be located on the bottom, near the "ball." More information on this error can be obtained from the support web site, or from referencing the error message code in the Troubleshooting Guide that accompanied your system. Please call HP Warranty Support for assistance.
030311 Keyboard Device, Key Press Test Keyboard LED This test failed as a result of the left mouse button not registering a depression. To have passed, the system should have detected the depression of the left mouse button. Check the mouse connector and ensure that it was seated properly. If the mouse has a P/S2 connector, ensure that all pins are present. Ensure that no pins are bent on the connector. A failure of this test may indicate that a replacement mouse needs to be obtained. A spare part number for the mouse will be located on the bottom, near the "ball." More information on this error can be obtained from the support web site, or from referencing the error message code in the Troubleshooting Guide that accompanied your system. Please call HP Warranty Support for assistance.
032024 Keyboard Device, Key Press Test Keypress failed This test failed as a result of the right mouse button not registering a depression. To have passed, the system should have detected the depression of the right mouse button. Check the mouse connector and ensure that it was seated properly. If the mouse has a P/S2 connector, ensure that all pins are present. Ensure that no pins are bent on the connector. A failure of this test may indicate that a replacement mouse needs to be obtained. A spare part number for the mouse will be located on the bottom, near the "ball." More information on this error can be obtained from the support web site, or from referencing the error message code in the Troubleshooting Guide that accompanied your system. Please call HP Warranty Support for assistance.
030299 Keyboard Device, Key Press Test Invalid Scan Code found This test failed as a result of the middle mouse button not registering a depression. To have passed, the system should have detected the depression of the middle mouse button. Check the mouse connector and ensure that it was seated properly. If the mouse has a P/S2 connector, ensure that all pins are present. Ensure that no pins are bent on the connector. A failure of this test may indicate that a replacement mouse needs to be obtained. A spare part number for the mouse will be located on the bottom, near the "ball." More information on this error can be obtained from the support web site, or from referencing the error message code in the Troubleshooting Guide that accompanied your system. Please call HP Warranty Support for assistance.
020470 Memory Device, Address Test Memory compare mismatch This test verifies the integrity of the address busses connecting the processor(s) to the memory modules. This is done by writing data to all possible addresses that have only one bit either set (1) or reset (0), having alternating bits set, having all bits high and having all bits low. The purpose of this test is to check for address lines that are either shorted to ground, shorted to a high voltage signal, shorted to other address lines, or floating (disconnected). This test alone, however, may not indicate a hard failure. It is recommended that a visual inspection of all memory modules be performed, ensuring that all modules are properly seated and locked into place. (Arbitrarily re-seating of all DIMMs is not necessary, and not recommended) Repeating this test may possibly repair the problem found. To properly isolate the problem DIMM, run this test continuously in "run on errors" mode. If consistent failures of this test occur, this indicates a problem with the address bus, which can be between processor board(s), system board, and memory board(s) (where applicable). Please call HP Warranty Support for assistance in obtaining the appropriate part (number can be found in "Help").
020471 Memory Device, Address Test Error correction code This test failed as a result of the ECC (error correcting code) reporting an error while the test was operating. While not a problem with the test itself, this indicates that there was an ECC error incident while the test was running. Check the IML for any ECC Threshold Passed events. The appropriate DIMM will be noted in the error message itself. If necessary, call HP Warranty Support for assistance (number can be found in "Help").
020472 Memory Device, Address Test Driver not loaded Make sure that the cpqdvmkd.o driver is loaded.
020473 Memory Device, Address Test Memory allocation Contact HP for assistance.
020474 Memory Device, Address Test Invalid parameters Make sure that the input parameters are correct.
020475 Memory Device, Address Test Driver did not process command Make sure that the cpqdvmkd.o driver is loaded.
020570 Memory Device, Walk Test Memory compare mismatch This test verifies the integrity of the address busses connecting the processor(s) to the memory modules. This is done by writing data to all possible addresses that have only one bit either set (1) or reset (0), having alternating bits set, having all bits high and having all bits low. The purpose of this test is to check for address lines that are either shorted to ground, shorted to a high voltage signal, shorted to other address lines, or floating (disconnected). This test alone, however, may not indicate a hard failure. It is recommended that a visual inspection of all memory modules be performed, ensuring that all modules are properly seated and locked into place. (Arbitrarily re-seating of all DIMMs is not necessary, and not recommended) Repeating this test may possibly repair the problem found. To properly isolate the problem DIMM, run this test continuously in "run on errors" mode. If consistent failures of this test occur, this indicates a problem with the address bus, which can be between processor board(s), system board, and memory board(s) (where applicable). Please call HP Warranty Support for assistance in obtaining the appropriate part (number can be found in "Help").
020571 Memory Device, Walk Test Error correction code This test failed as a result of the ECC (error correcting code) reporting an error while the test was operating. While not a problem with the test itself, this indicates that there was an ECC error incident while the test was running. Check the IML for any ECC Threshold Passed events. The appropriate DIMM will be noted in the error message itself. If necessary, call HP Warranty Support for assistance (number can be found in "Help").
020572 Memory Device, Walk Test Driver not loaded Make sure that the cpqdvmkd.o driver is loaded.
020573 Memory Device, Walk Test Memory allocation Contact HP for assistance.
020574 Memory Device, Walk Test Invalid parameters Make sure that the input parameters are correct.
020575 Memory Device, Walk Test Driver did not process command Make sure that the cpqdvmkd.o driver is loaded.
021470 Memory Device, Noise Test Memory compare mismatch This test verifies memory integrity by writing the inverse of the current test address to the current test address. The current test address alternates between the start and the end of the current test block, incrementing or decrementing the address until the entire test block has been accessed. The purpose of this test is to check for address and data bus transition problems when these lines are forced high and low as rapidly as possible. A failure of this test indicates a failure of the DIMM. To properly isolate the problem DIMM, run this test continuously in "run on errors" mode. The appropriate DIMM to be replaced should be noted in the error message itself. Please call HP Warranty Support for assistance (number can be found in "Help").
021471 Memory Device, Noise Test Error correction code This test failed as a result of the ECC (error correcting code) reporting an error while the test was operating. While not a problem with the test itself, this indicates that there was an ECC error incident while the test was running. Check the IML for any ECC Threshold Passed events. The appropriate DIMM will be noted in the error message itself. If necessary, call HP Warranty Support for assistance (number can be found in "Help").
021472 Memory Device, Noise Test Driver not loaded Make sure that the cpqdvmkd.o driver is loaded.
021473 Memory Device, Noise Test Memory allocation Contact HP for assistance.
021474 Memory Device, Noise Test Invalid parameters Make sure that the input parameters are correct.
021475 Memory Device, Noise Test Driver did not process command Make sure that the cpqdvmkd.o driver is loaded.
021570 Memory Device, Random Address Test Memory compare mismatch This test verifies memory integrity by running random patterns across a given test range. The addresses used to store the patterns are randomly selected and normalized to fit within the current test block. The purpose of this test is to detect intermittent memory problems that can be caused by temperature, variable clock speeds, variable voltages, signal timing, manufacturing faults, variable refresh rates, and decay. This test is also useful in detecting memory faults that may not be detected by other static tests. This test could have failed due to excessive heat around the memory module. Ensure that there is proper ventilation and cooling for the server, and that the front and rear of the server has appropriate clearance for proper cooling. Check diagnostics for temperature inside the server, and also check the Integrated Management Log for any heat-related events. A failure of this test indicates a failure of the DIMM. To properly isolate the problem DIMM, run this test continuously in "run on errors" mode. The appropriate DIMM to be replaced should be noted in the error message itself. Please call HP Warranty Support for assistance (number can be found in "Help").
021571 Memory Device, Random Address Test Error correction code This test failed as a result of the ECC (error correcting code) reporting an error while the test was operating. While not a problem with the test itself, this indicates that there was an ECC error incident while the test was running. Check the IML for any ECC Threshold Passed events. The appropriate DIMM will be noted in the error message itself. If necessary, call HP Warranty Support for assistance (number can be found in "Help").
021572 Memory Device, Random Address Test Driver not loaded Make sure that the cpqdvmkd.o driver is loaded.
021573 Memory Device, Random Address Test Memory allocation Contact HP for assistance.
021574 Memory Device, Random Address Test Invalid parameters Make sure that the input parameters are correct.
021575 Memory Device, Random Address Test Driver did not process command Make sure that the cpqdvmkd.o driver is loaded.
022670 Memory Device, Cache Test Memory compare mismatch This test verifies memory integrity by running random patterns across a given test range. The addresses used to store the patterns are randomly selected and normalized to fit within the current test block. The purpose of this test is to detect intermittent memory problems that can be caused by temperature, variable clock speeds, variable voltages, signal timing, manufacturing faults, variable refresh rates, and decay. This test is also useful in detecting memory faults that may not be detected by other static tests. This test could have failed due to excessive heat around the memory module. Ensure that there is proper ventilation and cooling for the server, and that the front and rear of the server has appropriate clearance for proper cooling. Check diagnostics for temperature inside the server, and also check the Integrated Management Log for any heat-related events. A failure of this test indicates a failure of the DIMM. To properly isolate the problem DIMM, run this test continuously in "run on errors" mode. The appropriate DIMM to be replaced should be noted in the error message itself. Please call HP Warranty Support for assistance (number can be found in "Help").
022671 Memory Device, Cache Test Error correction code This test failed as a result of the ECC (error correcting code) reporting an error while the test was operating. While not a problem with the test itself, this indicates that there was an ECC error incident while the test was running. Check the IML for any ECC Threshold Passed events. The appropriate DIMM will be noted in the error message itself. If necessary, call HP Warranty Support for assistance (number can be found in "Help").
022672 Memory Device, Cache Test Driver not loaded Make sure that the cpqdvmkd.o driver is loaded.
022673 Memory Device, Cache Test Memory allocation Contact HP for assistance.
022674 Memory Device, Cache Test Invalid parameters Make sure that the input parameters are correct.
022675 Memory Device, Cache Test Driver did not process command Make sure that the cpqdvmkd.o driver is loaded.
023270 Memory Device, March Test Memory compare mismatch This test is similar to a true walk bit test and is able to detect the following: address faults, stuck-at faults, transition faults, coupling faults, and linked coupling faults. These types of faults occur when memory cells within a bit cell array affect the operation of nearby memory cells. In many cases, static type tests will not detect these failures. A failure of this test indicates a failure of the DIMM. To properly isolate the problem DIMM, run this test continuously in "run on errors" mode. The appropriate DIMM to be replaced should be noted in the error message itself. Please call HP Warranty Support for assistance (number can be found in "Help").
023271 Memory Device, March Test Error correction code This test failed as a result of the ECC (error correcting code) reporting an error while the test was operating. While not a problem with the test itself, this indicates that there was an ECC error incident while the test was running. Check the IML for any ECC Threshold Passed events. The appropriate DIMM will be noted in the error message itself. If necessary, call HP Warranty Support for assistance (number can be found in "Help").
023272 Memory Device, March Test Driver not loaded Make sure that the cpqdvmkd.o driver is loaded.
023273 Memory Device, March Test Memory allocation Contact HP for assistance.
023274 Memory Device, March Test Invalid parameters Make sure that the input parameters are correct.
023275 Memory Device, March Test Driver did not process command Make sure that the cpqdvmkd.o driver is loaded.
023070 Memory Device, Read Test Memory compare mismatch This test verifies memory integrity by writing the inverse of the current test address to the current test address. The current test address alternates between the start and the end of the current test block, incrementing or decrementing the address until the entire test block has been accessed. The purpose of this test is to check for address and data bus transition problems when these lines are forced high and low as rapidly as possible. A failure of this test indicates a failure of the DIMM. To properly isolate the problem DIMM, run this test continuously in "run on errors" mode. The appropriate DIMM to be replaced should be noted in the error message itself. Please call HP Warranty Support for assistance (number can be found in "Help").
023071 Memory Device, Read Test Error correction code This test failed as a result of the ECC (error correcting code) reporting an error while the test was operating. While not a problem with the test itself, this indicates that there was an ECC error incident while the test was running. Check the IML for any ECC Threshold Passed events. The appropriate DIMM will be noted in the error message itself. If necessary, call HP Warranty Support for assistance (number can be found in "Help").
023072 Memory Device, Read Test Driver not loaded Make sure that the cpqdvmkd.o driver is loaded.
023073 Memory Device, Read Test Memory allocation Contact HP for assistance.
023074 Memory Device, Read Test Invalid parameters Make sure that the input parameters are correct.
023075 Memory Device, Read Test Driver did not process command Make sure that the cpqdvmkd.o driver is loaded.
021270 Memory Device, ECC Test Memory compare mismatch This test verifies memory integrity by writing the inverse of the current test address to the current test address. The current test address alternates between the start and the end of the current test block, incrementing or decrementing the address until the entire test block has been accessed. The purpose of this test is to check for address and data bus transition problems when these lines are forced high and low as rapidly as possible. A failure of this test indicates a failure of the DIMM. To properly isolate the problem DIMM, run this test continuously in "run on errors" mode. The appropriate DIMM to be replaced should be noted in the error message itself. Please call HP Warranty Support for assistance (number can be found in "Help").
021271 Memory Device, ECC Test Error correction code This test failed as a result of the ECC (error correcting code) reporting an error while the test was operating. While not a problem with the test itself, this indicates that there was an ECC error incident while the test was running. Check the IML for any ECC Threshold Passed events. The appropriate DIMM will be noted in the error message itself. If necessary, call HP Warranty Support for assistance (number can be found in "Help").
021272 Memory Device, ECC Test Driver not loaded Make sure that the cpqdvmkd.o driver is loaded.
021273 Memory Device, ECC Test Memory allocation Contact HP for assistance.
021274 Memory Device, ECC Test Invalid parameters Make sure that the input parameters are correct.
021275 Memory Device, ECC Test Driver did not process command Make sure that the cpqdvmkd.o driver is loaded.
072010 Mouse Device, Pointer Test left button not detected This test failed as a result of the left mouse button not registering a depression. To have passed, the system should have detected the depression of the left mouse button. Check the mouse connector and ensure that it was seated properly. If the mouse has a P/S2 connector, ensure that all pins are present. Ensure that no pins are bent on the connector. A failure of this test may indicate that a replacement mouse needs to be obtained. A spare part number for the mouse will be located on the bottom, near the "ball." More information on this error can be obtained from the support web site, or from referencing the error message code in the Troubleshooting Guide that accompanied your system. Please call HP Warranty Support for assistance.
072011 Mouse Device, Pointer Test right button not detected This test failed as a result of the right mouse button not registering a depression. To have passed, the system should have detected the depression of the right mouse button. Check the mouse connector and ensure that it was seated properly. If the mouse has a P/S2 connector, ensure that all pins are present. Ensure that no pins are bent on the connector. A failure of this test may indicate that a replacement mouse needs to be obtained. A spare part number for the mouse will be located on the bottom, near the "ball." More information on this error can be obtained from the support web site, or from referencing the error message code in the Troubleshooting Guide that accompanied your system. Please call HP Warranty Support for assistance.
072012 Mouse Device, Pointer Test middle button not detected This test failed as a result of the middle mouse button not registering a depression. To have passed, the system should have detected the depression of the middle mouse button. Check the mouse connector and ensure that it was seated properly. If the mouse has a P/S2 connector, ensure that all pins are present. Ensure that no pins are bent on the connector. A failure of this test may indicate that a replacement mouse needs to be obtained. A spare part number for the mouse will be located on the bottom, near the "ball." More information on this error can be obtained from the support web site, or from referencing the error message code in the Troubleshooting Guide that accompanied your system. Please call HP Warranty Support for assistance.
072013 Mouse Device, Pointer Test mouse button not detected This test failed as a result of any mouse button not registering a depression. To have passed, the system should have detected a depression of the any mouse button. Check the mouse connector and ensure that it was seated properly. If the mouse has a P/S2 connector, ensure that all pins are present. Ensure that no pins are bent on the connector. A failure of this test may indicate that a replacement mouse needs to be obtained. A spare part number for the mouse will be located on the bottom, near the "ball." More information on this error can be obtained from the support web site, or from referencing the error message code in the Troubleshooting Guide that accompanied your system. Please call HP Warranty Support for assistance.
072014 Mouse Device, Pointer Test mouse movement not detected This test failed as a result of the mouse button not registering any movement. To have passed, the system should have detected the movement of the mouse. Check the mouse connector and ensure that it was seated properly. If the mouse has a P/S2 connector, ensure that all pins are present. Ensure that no pins are bent on the connector. A failure of this test may indicate that a replacement mouse needs to be obtained. A spare part number for the mouse will be located on the bottom, near the "ball." More information on this error can be obtained from the support web site, or from referencing the error message code in the Troubleshooting Guide that accompanied your system. Please call HP Warranty Support for assistance.
072015 Mouse Device, Pointer Test mouse port read failed This test failed due to the failure of the system to read the mouse port.
604101 Network Device, Rom Test Invalid MAC address This test failed as a result of diagnostics` inability to properly interrogate the ROM of the NIC. To have passed, the system should have responded appropriately. It may be necessary to re-seat the NIC, or to move the NIC to another slot (if possible). Check the NIC`s configuration within the OS. More information on this error can be obtained from the support web site, or from referencing the error message code in the Troubleshooting Guide that accompanied your system.
604201 Network Device, IRQ Test Did not detect NIC interrupt This test failed as a result of the NIC not allocating IRQ properly. To have passed, the system should have had it is IRQ assigned appropriately. It may be necessary to re-seat the NIC, or to move the NIC to another slot (if possible). Check the NIC`s configuration within the OS. More information on this error can be obtained from the support web site, or from referencing the error message code in the Troubleshooting Guide that accompanied your system.
604301 Network Device, BIST Test Firmware reported problem It may be necessary to re-seat the NIC, or to move the NIC to another slot (if possible). Check the NIC`s configuration within the OS. More information on this error can be obtained from the support web site, or from referencing the error message code in the Troubleshooting Guide that accompanied your system.
604401 Network Device, Wakeup Test Did not receive wakeup packet This test failed as a result of diagnostics` inability to properly wake the NIC. To have passed, the system should have responded appropriately. It may be necessary to re-seat the NIC, or to move the NIC to another slot (if possible). Check the NIC`s configuration within the OS. Ensure that the NIC`s connection to the network is reseated, and also ensure that the media used to connect to the network is known-good. More information on this error can be obtained from the support web site, or from referencing the error message code in the Troubleshooting Guide that accompanied your system.
604501 Network Device, Ping Test Could not ping remote machine This test failed as a result of diagnostics` inability to ping the NIC. To have passed, the system should have responded appropriately. It may be necessary to re-seat the NIC, or to move the NIC to another slot (if possible). Check the NIC`s configuration within the OS. Ensure that the NIC`s connection to the network is reseated, and also ensure that the media used to connect to the network is known-good. More information on this error can be obtained from the support web site, or from referencing the error message code in the Troubleshooting Guide that accompanied your system.
604601 Network Device, LED Test User did not detect LED blink This test failed as a result of diagnostics` inability to properly detect the NIC`s LED status. To have passed, the system should have responded appropriately. It may be necessary to re-seat the NIC, or to move the NIC to another slot (if possible). Check the NIC`s configuration within the OS. Ensure that the NIC`s connection to the network is reseated, and also ensure that the media used to connect to the network is known-good. More information on this error can be obtained from the support web site, or from referencing the error message code in the Troubleshooting Guide that accompanied your system.
604701 Network Device, Dump MAC Test Detected duplicate MAC address This test failed as a result of diagnostics` finding a duplicate MAC address on the network. To have passed, the system should have possessed a unique MAC address. It may be necessary to re-program the NIC NVRAM with a unique MAC address. More information on this error can be obtained from the support web site, or from referencing the error message code in the Troubleshooting Guide that accompanied your system.
604801 Network Device, MAC Range Test MAC address out of range Verify MAC Range in the INI file
605001 Network Device, Checksum Test ROM checksum mismatch ROM Checksum did not match, reprogram NVRAM
605101 Network Device, Cable Test Did not detect cable status This test failed as a result of diagnostics` inability to properly utilize the network media for communications. To have passed, the system should have responded appropriately. Check the NIC`s configuration within the OS. Ensure that the NIC`s connection to the network is reseated, and also ensure that the media used to connect to the network is known-good. More information on this error can be obtained from the support web site, or from referencing the error message code in the Troubleshooting Guide that accompanied your system.
605201 Network Device, Speed Test Connection speed did not match This test failed as a result of diagnostics` inability to properly utilize the network media for communications at a speed that was expected. To have passed, the system should have responded appropriately at the tested speeds. Check the NIC`s configuration within the OS. Ensure that the NIC`s connection to the network is reseated, and also ensure that the media used to connect to the network is known-good. More information on this error can be obtained from the support web site, or from referencing the error message code in the Troubleshooting Guide that accompanied your system.
605201 Network Device, Speed Test Driver call unsupported This test failed as a result of diagnostics` inability to properly utilize the network media for communications at a speed that was expected. To have passed, the system should have responded appropriately at the tested speeds. Check the NIC`s configuration within the OS. Ensure that the NIC`s connection to the network is reseated, and also ensure that the media used to connect to the network is known-good. More information on this error can be obtained from the support web site, or from referencing the error message code in the Troubleshooting Guide that accompanied your system.
605301 Network Device, Wake-On-LAN test Could not shutdown system This test failed as a result of diagnostics` inability to properly wake the NIC. To have passed, the system should have responded appropriately. It may be necessary to re-seat the NIC, or to move the NIC to another slot (if possible). Check the NIC`s configuration within the OS. Ensure that the NIC`s connection to the network is reseated, and also ensure that the media used to connect to the network is known-good. More information on this error can be obtained from the support web site, or from referencing the error message code in the Troubleshooting Guide that accompanied your system.
605302 Network Device, Wake-On-LAN test Could not read state This test failed as a result of diagnostics` inability to properly wake the NIC. To have passed, the system should have responded appropriately. It may be necessary to re-seat the NIC, or to move the NIC to another slot (if possible). Check the NIC`s configuration within the OS. Ensure that the NIC`s connection to the network is reseated, and also ensure that the media used to connect to the network is known-good. More information on this error can be obtained from the support web site, or from referencing the error message code in the Troubleshooting Guide that accompanied your system.
605303 Network Device, Wake-On-LAN test Could not write state This test failed as a result of diagnostics` inability to properly wake the NIC. To have passed, the system should have responded appropriately. It may be necessary to re-seat the NIC, or to move the NIC to another slot (if possible). Check the NIC`s configuration within the OS. Ensure that the NIC`s connection to the network is reseated, and also ensure that the media used to connect to the network is known-good. More information on this error can be obtained from the support web site, or from referencing the error message code in the Troubleshooting Guide that accompanied your system.
605304 Network Device, Wake-On-LAN test Could not send wake-up request This test failed as a result of diagnostics` inability to properly wake the NIC. To have passed, the system should have responded appropriately. It may be necessary to re-seat the NIC, or to move the NIC to another slot (if possible). Check the NIC`s configuration within the OS. Ensure that the NIC`s connection to the network is reseated, and also ensure that the media used to connect to the network is known-good. More information on this error can be obtained from the support web site, or from referencing the error message code in the Troubleshooting Guide that accompanied your system.
605305 Network Device, Wake-On-LAN test WOL server not found This test failed as a result of diagnostics` inability to properly wake the NIC. To have passed, the system should have responded appropriately. It may be necessary to re-seat the NIC, or to move the NIC to another slot (if possible). Check the NIC`s configuration within the OS. Ensure that the NIC`s connection to the network is reseated, and also ensure that the media used to connect to the network is known-good. More information on this error can be obtained from the support web site, or from referencing the error message code in the Troubleshooting Guide that accompanied your system.
605401 Network Device, Network heartbeat test Did not receive heartbeat Undefined Repair
041080 Parallel Device, Crtl Register Test Invalid data on strobe line Make sure there is no external device attached to parallel port
041081 Parallel Device, Crtl Register Test Invalid data on auto feed line Make sure there is no external device attached to parallel port
041082 Parallel Device, Crtl Register Test Invalid data on init line Make sure there is no external device attached to parallel port
041083 Parallel Device, Crtl Register Test Invalid data on select-in line Make sure there is no external device attached to parallel port
041084 Parallel Device, Data Register Test Invalid data on data lines Make sure the printer is not busy
041085 Parallel Device, Loopback Test Invalid data on busy line Plug an external loopback on the parallel port
041086 Parallel Device, Loopback Test Invalid data on ack line Plug an external loopback on the parallel port
041087 Parallel Device, Loopback Test Invalid data on PE line Plug an external loopback on the parallel port
041089 Parallel Device, Loopback Test Invalid data on select line Plug an external loopback on the parallel port
041090 Parallel Device, Loopback Test Invalid data on error line Plug an external loopback on the parallel port
417072 PCI, Read Test PCI bus read invalid data This test failed because the vendor ID and device ID were invalid. More information on this error can be obtained from the support web site, or from referencing the error message code in the Troubleshooting Guide that accompanied your system. Please call HP Warranty Support for assistance.
115028 Serial Device, Register Test Line control register Undefined Repair
115029 Serial Device, Register Test Modem control register Undefined Repair
115107 Serial Device, Internal Test Unable to read serial port Undefined Repair
115108 Serial Device, Internal Test Unable to write serial port Undefined Repair
115109 Serial Device, Internal Test Mismatching read and write Undefined Repair
115207 Serial Device, External Test Unable to read serial port Check to ensure that the external loopback device is plugged in
115208 Serial Device, External Test Unable to write serial port Check to ensure that the external loopback device is plugged in
115209 Serial Device, External Test Mismatching read and write Check to ensure that the external loopback device is plugged in
420202 Backplane, SCSI Self Test BMIC driver reported problem Check that Smart Array firmware and device drivers are up to date
420505 Backplane, SCSI Self Test Cannot open filesystem table Use a more recent version of diagnostics
420303 Backplane, SCSI Self Test CISS driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Backplane, SCSI Self Test Driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Backplane, SCSI Self Test Controller is not supported Check that Smart Array firmware and device drivers are up to date
420710 Backplane, SCSI Self Test Error limit exceeded Replace disk drive or media
420505 Backplane, SCSI Self Test No fibre channel port selected Use a more recent version of diagnostics
420505 Backplane, SCSI Self Test Could not access file Use a more recent version of diagnostics
420505 Backplane, SCSI Self Test Invalid access order Select a different access order for this test
420505 Backplane, SCSI Self Test Invalid parameter list Select different parameters for this test
420710 Backplane, SCSI Self Test Could not access media Replace disk drive or media
420202 Backplane, SCSI Self Test Cannot determine bus speed Check that Smart Array firmware and device drivers are up to date
420202 Backplane, SCSI Self Test Cannot determine bus width Check that Smart Array firmware and device drivers are up to date
420505 Backplane, SCSI Self Test SCSI command is not supported Use a more recent version of diagnostics
420505 Backplane, SCSI Self Test SCSI adapter not implemented Use a more recent version of diagnostics
420710 Backplane, SCSI Self Test Could not transfer SCSI data Check SCSI cables and connectors
420505 Backplane, SCSI Self Test SCSI device not implemented Use a more recent version of diagnostics
420505 Backplane, SCSI Self Test Undefined SCSI adapter Use a more recent version of diagnostics
420505 Backplane, SCSI Self Test Device reported problem Use a more recent version of diagnostics
420505 Backplane, SCSI Self Test Unknown device type Use a more recent version of diagnostics
420202 Backplane, Bus Speed Test BMIC driver reported problem Check that Smart Array firmware and device drivers are up to date
420505 Backplane, Bus Speed Test Cannot open filesystem table Use a more recent version of diagnostics
420303 Backplane, Bus Speed Test CISS driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Backplane, Bus Speed Test Driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Backplane, Bus Speed Test Controller is not supported Check that Smart Array firmware and device drivers are up to date
420710 Backplane, Bus Speed Test Error limit exceeded Replace disk drive or media
420505 Backplane, Bus Speed Test No fibre channel port selected Use a more recent version of diagnostics
420505 Backplane, Bus Speed Test Could not access file Use a more recent version of diagnostics
420505 Backplane, Bus Speed Test Invalid access order Select a different access order for this test
420505 Backplane, Bus Speed Test Invalid parameter list Select different parameters for this test
420710 Backplane, Bus Speed Test Could not access media Replace disk drive or media
420202 Backplane, Bus Speed Test Cannot determine bus speed Check that Smart Array firmware and device drivers are up to date
420202 Backplane, Bus Speed Test Cannot determine bus width Check that Smart Array firmware and device drivers are up to date
420505 Backplane, Bus Speed Test SCSI command is not supported Use a more recent version of diagnostics
420505 Backplane, Bus Speed Test SCSI adapter not implemented Use a more recent version of diagnostics
420710 Backplane, Bus Speed Test Could not transfer SCSI data Check SCSI cables and connectors
420505 Backplane, Bus Speed Test SCSI device not implemented Use a more recent version of diagnostics
420505 Backplane, Bus Speed Test Undefined SCSI adapter Use a more recent version of diagnostics
420505 Backplane, Bus Speed Test Device reported problem Use a more recent version of diagnostics
420505 Backplane, Bus Speed Test Unknown device type Use a more recent version of diagnostics
420202 Backplane, Sequential Verify Test BMIC driver reported problem Check that Smart Array firmware and device drivers are up to date
420505 Backplane, Sequential Verify Test Cannot open filesystem table Use a more recent version of diagnostics
420303 Backplane, Sequential Verify Test CISS driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Backplane, Sequential Verify Test Driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Backplane, Sequential Verify Test Controller is not supported Check that Smart Array firmware and device drivers are up to date
420710 Backplane, Sequential Verify Test Error limit exceeded Replace disk drive or media
420505 Backplane, Sequential Verify Test No fibre channel port selected Use a more recent version of diagnostics
420505 Backplane, Sequential Verify Test Could not access file Use a more recent version of diagnostics
420505 Backplane, Sequential Verify Test Invalid access order Select a different access order for this test
420505 Backplane, Sequential Verify Test Invalid parameter list Select different parameters for this test
420710 Backplane, Sequential Verify Test Could not access media Replace disk drive or media
420202 Backplane, Sequential Verify Test Cannot determine bus speed Check that Smart Array firmware and device drivers are up to date
420202 Backplane, Sequential Verify Test Cannot determine bus width Check that Smart Array firmware and device drivers are up to date
420505 Backplane, Sequential Verify Test SCSI command is not supported Use a more recent version of diagnostics
420505 Backplane, Sequential Verify Test SCSI adapter not implemented Use a more recent version of diagnostics
420710 Backplane, Sequential Verify Test Could not transfer SCSI data Check SCSI cables and connectors
420505 Backplane, Sequential Verify Test SCSI device not implemented Use a more recent version of diagnostics
420505 Backplane, Sequential Verify Test Undefined SCSI adapter Use a more recent version of diagnostics
420505 Backplane, Sequential Verify Test Device reported problem Use a more recent version of diagnostics
420505 Backplane, Sequential Verify Test Unknown device type Use a more recent version of diagnostics
420202 Backplane, Sequential Read Test BMIC driver reported problem Check that Smart Array firmware and device drivers are up to date
420505 Backplane, Sequential Read Test Cannot open filesystem table Use a more recent version of diagnostics
420303 Backplane, Sequential Read Test CISS driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Backplane, Sequential Read Test Driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Backplane, Sequential Read Test Controller is not supported Check that Smart Array firmware and device drivers are up to date
420710 Backplane, Sequential Read Test Error limit exceeded Replace disk drive or media
420505 Backplane, Sequential Read Test No fibre channel port selected Use a more recent version of diagnostics
420505 Backplane, Sequential Read Test Could not access file Use a more recent version of diagnostics
420505 Backplane, Sequential Read Test Invalid access order Select a different access order for this test
420505 Backplane, Sequential Read Test Invalid parameter list Select different parameters for this test
420710 Backplane, Sequential Read Test Could not access media Replace disk drive or media
420202 Backplane, Sequential Read Test Cannot determine bus speed Check that Smart Array firmware and device drivers are up to date
420202 Backplane, Sequential Read Test Cannot determine bus width Check that Smart Array firmware and device drivers are up to date
420505 Backplane, Sequential Read Test SCSI command is not supported Use a more recent version of diagnostics
420505 Backplane, Sequential Read Test SCSI adapter not implemented Use a more recent version of diagnostics
420710 Backplane, Sequential Read Test Could not transfer SCSI data Check SCSI cables and connectors
420505 Backplane, Sequential Read Test SCSI device not implemented Use a more recent version of diagnostics
420505 Backplane, Sequential Read Test Undefined SCSI adapter Use a more recent version of diagnostics
420505 Backplane, Sequential Read Test Device reported problem Use a more recent version of diagnostics
420505 Backplane, Sequential Read Test Unknown device type Use a more recent version of diagnostics
420202 Backplane, Butterfly Read Test BMIC driver reported problem Check that Smart Array firmware and device drivers are up to date
420505 Backplane, Butterfly Read Test Cannot open filesystem table Use a more recent version of diagnostics
420303 Backplane, Butterfly Read Test CISS driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Backplane, Butterfly Read Test Driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Backplane, Butterfly Read Test Controller is not supported Check that Smart Array firmware and device drivers are up to date
420710 Backplane, Butterfly Read Test Error limit exceeded Replace disk drive or media
420505 Backplane, Butterfly Read Test No fibre channel port selected Use a more recent version of diagnostics
420505 Backplane, Butterfly Read Test Could not access file Use a more recent version of diagnostics
420505 Backplane, Butterfly Read Test Invalid access order Select a different access order for this test
420505 Backplane, Butterfly Read Test Invalid parameter list Select different parameters for this test
420710 Backplane, Butterfly Read Test Could not access media Replace disk drive or media
420202 Backplane, Butterfly Read Test Cannot determine bus speed Check that Smart Array firmware and device drivers are up to date
420202 Backplane, Butterfly Read Test Cannot determine bus width Check that Smart Array firmware and device drivers are up to date
420505 Backplane, Butterfly Read Test SCSI command is not supported Use a more recent version of diagnostics
420505 Backplane, Butterfly Read Test SCSI adapter not implemented Use a more recent version of diagnostics
420710 Backplane, Butterfly Read Test Could not transfer SCSI data Check SCSI cables and connectors
420505 Backplane, Butterfly Read Test SCSI device not implemented Use a more recent version of diagnostics
420505 Backplane, Butterfly Read Test Undefined SCSI adapter Use a more recent version of diagnostics
420505 Backplane, Butterfly Read Test Device reported problem Use a more recent version of diagnostics
420505 Backplane, Butterfly Read Test Unknown device type Use a more recent version of diagnostics
420202 Backplane, Random Read Test BMIC driver reported problem Check that Smart Array firmware and device drivers are up to date
420505 Backplane, Random Read Test Cannot open filesystem table Use a more recent version of diagnostics
420303 Backplane, Random Read Test CISS driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Backplane, Random Read Test Driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Backplane, Random Read Test Controller is not supported Check that Smart Array firmware and device drivers are up to date
420710 Backplane, Random Read Test Error limit exceeded Replace disk drive or media
420505 Backplane, Random Read Test No fibre channel port selected Use a more recent version of diagnostics
420505 Backplane, Random Read Test Could not access file Use a more recent version of diagnostics
420505 Backplane, Random Read Test Invalid access order Select a different access order for this test
420505 Backplane, Random Read Test Invalid parameter list Select different parameters for this test
420710 Backplane, Random Read Test Could not access media Replace disk drive or media
420202 Backplane, Random Read Test Cannot determine bus speed Check that Smart Array firmware and device drivers are up to date
420202 Backplane, Random Read Test Cannot determine bus width Check that Smart Array firmware and device drivers are up to date
420505 Backplane, Random Read Test SCSI command is not supported Use a more recent version of diagnostics
420505 Backplane, Random Read Test SCSI adapter not implemented Use a more recent version of diagnostics
420710 Backplane, Random Read Test Could not transfer SCSI data Check SCSI cables and connectors
420505 Backplane, Random Read Test SCSI device not implemented Use a more recent version of diagnostics
420505 Backplane, Random Read Test Undefined SCSI adapter Use a more recent version of diagnostics
420505 Backplane, Random Read Test Device reported problem Use a more recent version of diagnostics
420505 Backplane, Random Read Test Unknown device type Use a more recent version of diagnostics
420202 Backplane, Sequential Seek Test BMIC driver reported problem Check that Smart Array firmware and device drivers are up to date
420505 Backplane, Sequential Seek Test Cannot open filesystem table Use a more recent version of diagnostics
420303 Backplane, Sequential Seek Test CISS driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Backplane, Sequential Seek Test Driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Backplane, Sequential Seek Test Controller is not supported Check that Smart Array firmware and device drivers are up to date
420710 Backplane, Sequential Seek Test Error limit exceeded Replace disk drive or media
420505 Backplane, Sequential Seek Test No fibre channel port selected Use a more recent version of diagnostics
420505 Backplane, Sequential Seek Test Could not access file Use a more recent version of diagnostics
420505 Backplane, Sequential Seek Test Invalid access order Select a different access order for this test
420505 Backplane, Sequential Seek Test Invalid parameter list Select different parameters for this test
420710 Backplane, Sequential Seek Test Could not access media Replace disk drive or media
420202 Backplane, Sequential Seek Test Cannot determine bus speed Check that Smart Array firmware and device drivers are up to date
420202 Backplane, Sequential Seek Test Cannot determine bus width Check that Smart Array firmware and device drivers are up to date
420505 Backplane, Sequential Seek Test SCSI command is not supported Use a more recent version of diagnostics
420505 Backplane, Sequential Seek Test SCSI adapter not implemented Use a more recent version of diagnostics
420710 Backplane, Sequential Seek Test Could not transfer SCSI data Check SCSI cables and connectors
420505 Backplane, Sequential Seek Test SCSI device not implemented Use a more recent version of diagnostics
420505 Backplane, Sequential Seek Test Undefined SCSI adapter Use a more recent version of diagnostics
420505 Backplane, Sequential Seek Test Device reported problem Use a more recent version of diagnostics
420505 Backplane, Sequential Seek Test Unknown device type Use a more recent version of diagnostics
420202 Backplane, Butterfly Seek Test BMIC driver reported problem Check that Smart Array firmware and device drivers are up to date
420505 Backplane, Butterfly Seek Test Cannot open filesystem table Use a more recent version of diagnostics
420303 Backplane, Butterfly Seek Test CISS driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Backplane, Butterfly Seek Test Driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Backplane, Butterfly Seek Test Controller is not supported Check that Smart Array firmware and device drivers are up to date
420710 Backplane, Butterfly Seek Test Error limit exceeded Replace disk drive or media
420505 Backplane, Butterfly Seek Test No fibre channel port selected Use a more recent version of diagnostics
420505 Backplane, Butterfly Seek Test Could not access file Use a more recent version of diagnostics
420505 Backplane, Butterfly Seek Test Invalid access order Select a different access order for this test
420505 Backplane, Butterfly Seek Test Invalid parameter list Select different parameters for this test
420710 Backplane, Butterfly Seek Test Could not access media Replace disk drive or media
420202 Backplane, Butterfly Seek Test Cannot determine bus speed Check that Smart Array firmware and device drivers are up to date
420202 Backplane, Butterfly Seek Test Cannot determine bus width Check that Smart Array firmware and device drivers are up to date
420505 Backplane, Butterfly Seek Test SCSI command is not supported Use a more recent version of diagnostics
420505 Backplane, Butterfly Seek Test SCSI adapter not implemented Use a more recent version of diagnostics
420710 Backplane, Butterfly Seek Test Could not transfer SCSI data Check SCSI cables and connectors
420505 Backplane, Butterfly Seek Test SCSI device not implemented Use a more recent version of diagnostics
420505 Backplane, Butterfly Seek Test Undefined SCSI adapter Use a more recent version of diagnostics
420505 Backplane, Butterfly Seek Test Device reported problem Use a more recent version of diagnostics
420505 Backplane, Butterfly Seek Test Unknown device type Use a more recent version of diagnostics
420202 Backplane, Random Seek Test BMIC driver reported problem Check that Smart Array firmware and device drivers are up to date
420505 Backplane, Random Seek Test Cannot open filesystem table Use a more recent version of diagnostics
420303 Backplane, Random Seek Test CISS driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Backplane, Random Seek Test Driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Backplane, Random Seek Test Controller is not supported Check that Smart Array firmware and device drivers are up to date
420710 Backplane, Random Seek Test Error limit exceeded Replace disk drive or media
420505 Backplane, Random Seek Test No fibre channel port selected Use a more recent version of diagnostics
420505 Backplane, Random Seek Test Could not access file Use a more recent version of diagnostics
420505 Backplane, Random Seek Test Invalid access order Select a different access order for this test
420505 Backplane, Random Seek Test Invalid parameter list Select different parameters for this test
420710 Backplane, Random Seek Test Could not access media Replace disk drive or media
420202 Backplane, Random Seek Test Cannot determine bus speed Check that Smart Array firmware and device drivers are up to date
420202 Backplane, Random Seek Test Cannot determine bus width Check that Smart Array firmware and device drivers are up to date
420505 Backplane, Random Seek Test SCSI command is not supported Use a more recent version of diagnostics
420505 Backplane, Random Seek Test SCSI adapter not implemented Use a more recent version of diagnostics
420710 Backplane, Random Seek Test Could not transfer SCSI data Check SCSI cables and connectors
420505 Backplane, Random Seek Test SCSI device not implemented Use a more recent version of diagnostics
420505 Backplane, Random Seek Test Undefined SCSI adapter Use a more recent version of diagnostics
420505 Backplane, Random Seek Test Device reported problem Use a more recent version of diagnostics
420505 Backplane, Random Seek Test Unknown device type Use a more recent version of diagnostics
420202 Bmic Device, SCSI Self Test BMIC driver reported problem Check that Smart Array firmware and device drivers are up to date
420505 Bmic Device, SCSI Self Test Cannot open filesystem table Use a more recent version of diagnostics
420303 Bmic Device, SCSI Self Test CISS driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Bmic Device, SCSI Self Test Driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Bmic Device, SCSI Self Test Controller is not supported Check that Smart Array firmware and device drivers are up to date
420710 Bmic Device, SCSI Self Test Error limit exceeded Replace disk drive or media
420505 Bmic Device, SCSI Self Test No fibre channel port selected Use a more recent version of diagnostics
420505 Bmic Device, SCSI Self Test Could not access file Use a more recent version of diagnostics
420505 Bmic Device, SCSI Self Test Invalid access order Select a different access order for this test
420505 Bmic Device, SCSI Self Test Invalid parameter list Select different parameters for this test
420710 Bmic Device, SCSI Self Test Could not access media Replace disk drive or media
420202 Bmic Device, SCSI Self Test Cannot determine bus speed Check that Smart Array firmware and device drivers are up to date
420202 Bmic Device, SCSI Self Test Cannot determine bus width Check that Smart Array firmware and device drivers are up to date
420505 Bmic Device, SCSI Self Test SCSI command is not supported Use a more recent version of diagnostics
420505 Bmic Device, SCSI Self Test SCSI adapter not implemented Use a more recent version of diagnostics
420710 Bmic Device, SCSI Self Test Could not transfer SCSI data Check SCSI cables and connectors
420505 Bmic Device, SCSI Self Test SCSI device not implemented Use a more recent version of diagnostics
420505 Bmic Device, SCSI Self Test Undefined SCSI adapter Use a more recent version of diagnostics
420505 Bmic Device, SCSI Self Test Device reported problem Use a more recent version of diagnostics
420505 Bmic Device, SCSI Self Test Unknown device type Use a more recent version of diagnostics
420202 Bmic Device, Bus Speed Test BMIC driver reported problem Check that Smart Array firmware and device drivers are up to date
420505 Bmic Device, Bus Speed Test Cannot open filesystem table Use a more recent version of diagnostics
420303 Bmic Device, Bus Speed Test CISS driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Bmic Device, Bus Speed Test Driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Bmic Device, Bus Speed Test Controller is not supported Check that Smart Array firmware and device drivers are up to date
420710 Bmic Device, Bus Speed Test Error limit exceeded Replace disk drive or media
420505 Bmic Device, Bus Speed Test No fibre channel port selected Use a more recent version of diagnostics
420505 Bmic Device, Bus Speed Test Could not access file Use a more recent version of diagnostics
420505 Bmic Device, Bus Speed Test Invalid access order Select a different access order for this test
420505 Bmic Device, Bus Speed Test Invalid parameter list Select different parameters for this test
420710 Bmic Device, Bus Speed Test Could not access media Replace disk drive or media
420202 Bmic Device, Bus Speed Test Cannot determine bus speed Check that Smart Array firmware and device drivers are up to date
420202 Bmic Device, Bus Speed Test Cannot determine bus width Check that Smart Array firmware and device drivers are up to date
420505 Bmic Device, Bus Speed Test SCSI command is not supported Use a more recent version of diagnostics
420505 Bmic Device, Bus Speed Test SCSI adapter not implemented Use a more recent version of diagnostics
420710 Bmic Device, Bus Speed Test Could not transfer SCSI data Check SCSI cables and connectors
420505 Bmic Device, Bus Speed Test SCSI device not implemented Use a more recent version of diagnostics
420505 Bmic Device, Bus Speed Test Undefined SCSI adapter Use a more recent version of diagnostics
420505 Bmic Device, Bus Speed Test Device reported problem Use a more recent version of diagnostics
420505 Bmic Device, Bus Speed Test Unknown device type Use a more recent version of diagnostics
420202 Bmic Device, Sequential Verify Test BMIC driver reported problem Check that Smart Array firmware and device drivers are up to date
420505 Bmic Device, Sequential Verify Test Cannot open filesystem table Use a more recent version of diagnostics
420303 Bmic Device, Sequential Verify Test CISS driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Bmic Device, Sequential Verify Test Driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Bmic Device, Sequential Verify Test Controller is not supported Check that Smart Array firmware and device drivers are up to date
420710 Bmic Device, Sequential Verify Test Error limit exceeded Replace disk drive or media
420505 Bmic Device, Sequential Verify Test No fibre channel port selected Use a more recent version of diagnostics
420505 Bmic Device, Sequential Verify Test Could not access file Use a more recent version of diagnostics
420505 Bmic Device, Sequential Verify Test Invalid access order Select a different access order for this test
420505 Bmic Device, Sequential Verify Test Invalid parameter list Select different parameters for this test
420710 Bmic Device, Sequential Verify Test Could not access media Replace disk drive or media
420202 Bmic Device, Sequential Verify Test Cannot determine bus speed Check that Smart Array firmware and device drivers are up to date
420202 Bmic Device, Sequential Verify Test Cannot determine bus width Check that Smart Array firmware and device drivers are up to date
420505 Bmic Device, Sequential Verify Test SCSI command is not supported Use a more recent version of diagnostics
420505 Bmic Device, Sequential Verify Test SCSI adapter not implemented Use a more recent version of diagnostics
420710 Bmic Device, Sequential Verify Test Could not transfer SCSI data Check SCSI cables and connectors
420505 Bmic Device, Sequential Verify Test SCSI device not implemented Use a more recent version of diagnostics
420505 Bmic Device, Sequential Verify Test Undefined SCSI adapter Use a more recent version of diagnostics
420505 Bmic Device, Sequential Verify Test Device reported problem Use a more recent version of diagnostics
420505 Bmic Device, Sequential Verify Test Unknown device type Use a more recent version of diagnostics
420202 Bmic Device, Sequential Reasd Test BMIC driver reported problem Check that Smart Array firmware and device drivers are up to date
420505 Bmic Device, Sequential Reasd Test Cannot open filesystem table Use a more recent version of diagnostics
420303 Bmic Device, Sequential Reasd Test CISS driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Bmic Device, Sequential Reasd Test Driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Bmic Device, Sequential Reasd Test Controller is not supported Check that Smart Array firmware and device drivers are up to date
420710 Bmic Device, Sequential Reasd Test Error limit exceeded Replace disk drive or media
420505 Bmic Device, Sequential Reasd Test No fibre channel port selected Use a more recent version of diagnostics
420505 Bmic Device, Sequential Reasd Test Could not access file Use a more recent version of diagnostics
420505 Bmic Device, Sequential Reasd Test Invalid access order Select a different access order for this test
420505 Bmic Device, Sequential Reasd Test Invalid parameter list Select different parameters for this test
420710 Bmic Device, Sequential Reasd Test Could not access media Replace disk drive or media
420202 Bmic Device, Sequential Reasd Test Cannot determine bus speed Check that Smart Array firmware and device drivers are up to date
420202 Bmic Device, Sequential Reasd Test Cannot determine bus width Check that Smart Array firmware and device drivers are up to date
420505 Bmic Device, Sequential Reasd Test SCSI command is not supported Use a more recent version of diagnostics
420505 Bmic Device, Sequential Reasd Test SCSI adapter not implemented Use a more recent version of diagnostics
420710 Bmic Device, Sequential Reasd Test Could not transfer SCSI data Check SCSI cables and connectors
420505 Bmic Device, Sequential Reasd Test SCSI device not implemented Use a more recent version of diagnostics
420505 Bmic Device, Sequential Reasd Test Undefined SCSI adapter Use a more recent version of diagnostics
420505 Bmic Device, Sequential Reasd Test Device reported problem Use a more recent version of diagnostics
420505 Bmic Device, Sequential Reasd Test Unknown device type Use a more recent version of diagnostics
420202 Bmic Device, Butterfly Read Test BMIC driver reported problem Check that Smart Array firmware and device drivers are up to date
420505 Bmic Device, Butterfly Read Test Cannot open filesystem table Use a more recent version of diagnostics
420303 Bmic Device, Butterfly Read Test CISS driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Bmic Device, Butterfly Read Test Driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Bmic Device, Butterfly Read Test Controller is not supported Check that Smart Array firmware and device drivers are up to date
420710 Bmic Device, Butterfly Read Test Error limit exceeded Replace disk drive or media
420505 Bmic Device, Butterfly Read Test No fibre channel port selected Use a more recent version of diagnostics
420505 Bmic Device, Butterfly Read Test Could not access file Use a more recent version of diagnostics
420505 Bmic Device, Butterfly Read Test Invalid access order Select a different access order for this test
420505 Bmic Device, Butterfly Read Test Invalid parameter list Select different parameters for this test
420710 Bmic Device, Butterfly Read Test Could not access media Replace disk drive or media
420202 Bmic Device, Butterfly Read Test Cannot determine bus speed Check that Smart Array firmware and device drivers are up to date
420202 Bmic Device, Butterfly Read Test Cannot determine bus width Check that Smart Array firmware and device drivers are up to date
420505 Bmic Device, Butterfly Read Test SCSI command is not supported Use a more recent version of diagnostics
420505 Bmic Device, Butterfly Read Test SCSI adapter not implemented Use a more recent version of diagnostics
420710 Bmic Device, Butterfly Read Test Could not transfer SCSI data Check SCSI cables and connectors
420505 Bmic Device, Butterfly Read Test SCSI device not implemented Use a more recent version of diagnostics
420505 Bmic Device, Butterfly Read Test Undefined SCSI adapter Use a more recent version of diagnostics
420505 Bmic Device, Butterfly Read Test Device reported problem Use a more recent version of diagnostics
420505 Bmic Device, Butterfly Read Test Unknown device type Use a more recent version of diagnostics
420202 Bmic Device, Random Read Test BMIC driver reported problem Check that Smart Array firmware and device drivers are up to date
420505 Bmic Device, Random Read Test Cannot open filesystem table Use a more recent version of diagnostics
420303 Bmic Device, Random Read Test CISS driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Bmic Device, Random Read Test Driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Bmic Device, Random Read Test Controller is not supported Check that Smart Array firmware and device drivers are up to date
420710 Bmic Device, Random Read Test Error limit exceeded Replace disk drive or media
420505 Bmic Device, Random Read Test No fibre channel port selected Use a more recent version of diagnostics
420505 Bmic Device, Random Read Test Could not access file Use a more recent version of diagnostics
420505 Bmic Device, Random Read Test Invalid access order Select a different access order for this test
420505 Bmic Device, Random Read Test Invalid parameter list Select different parameters for this test
420710 Bmic Device, Random Read Test Could not access media Replace disk drive or media
420202 Bmic Device, Random Read Test Cannot determine bus speed Check that Smart Array firmware and device drivers are up to date
420202 Bmic Device, Random Read Test Cannot determine bus width Check that Smart Array firmware and device drivers are up to date
420505 Bmic Device, Random Read Test SCSI command is not supported Use a more recent version of diagnostics
420505 Bmic Device, Random Read Test SCSI adapter not implemented Use a more recent version of diagnostics
420710 Bmic Device, Random Read Test Could not transfer SCSI data Check SCSI cables and connectors
420505 Bmic Device, Random Read Test SCSI device not implemented Use a more recent version of diagnostics
420505 Bmic Device, Random Read Test Undefined SCSI adapter Use a more recent version of diagnostics
420505 Bmic Device, Random Read Test Device reported problem Use a more recent version of diagnostics
420505 Bmic Device, Random Read Test Unknown device type Use a more recent version of diagnostics
420202 Bmic Device, Sequential Seek Test BMIC driver reported problem Check that Smart Array firmware and device drivers are up to date
420505 Bmic Device, Sequential Seek Test Cannot open filesystem table Use a more recent version of diagnostics
420303 Bmic Device, Sequential Seek Test CISS driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Bmic Device, Sequential Seek Test Driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Bmic Device, Sequential Seek Test Controller is not supported Check that Smart Array firmware and device drivers are up to date
420710 Bmic Device, Sequential Seek Test Error limit exceeded Replace disk drive or media
420505 Bmic Device, Sequential Seek Test No fibre channel port selected Use a more recent version of diagnostics
420505 Bmic Device, Sequential Seek Test Could not access file Use a more recent version of diagnostics
420505 Bmic Device, Sequential Seek Test Invalid access order Select a different access order for this test
420505 Bmic Device, Sequential Seek Test Invalid parameter list Select different parameters for this test
420710 Bmic Device, Sequential Seek Test Could not access media Replace disk drive or media
420202 Bmic Device, Sequential Seek Test Cannot determine bus speed Check that Smart Array firmware and device drivers are up to date
420202 Bmic Device, Sequential Seek Test Cannot determine bus width Check that Smart Array firmware and device drivers are up to date
420505 Bmic Device, Sequential Seek Test SCSI command is not supported Use a more recent version of diagnostics
420505 Bmic Device, Sequential Seek Test SCSI adapter not implemented Use a more recent version of diagnostics
420710 Bmic Device, Sequential Seek Test Could not transfer SCSI data Check SCSI cables and connectors
420505 Bmic Device, Sequential Seek Test SCSI device not implemented Use a more recent version of diagnostics
420505 Bmic Device, Sequential Seek Test Undefined SCSI adapter Use a more recent version of diagnostics
420505 Bmic Device, Sequential Seek Test Device reported problem Use a more recent version of diagnostics
420505 Bmic Device, Sequential Seek Test Unknown device type Use a more recent version of diagnostics
420202 Bmic Device, Butterfly Seek Test BMIC driver reported problem Check that Smart Array firmware and device drivers are up to date
420505 Bmic Device, Butterfly Seek Test Cannot open filesystem table Use a more recent version of diagnostics
420303 Bmic Device, Butterfly Seek Test CISS driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Bmic Device, Butterfly Seek Test Driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Bmic Device, Butterfly Seek Test Controller is not supported Check that Smart Array firmware and device drivers are up to date
420710 Bmic Device, Butterfly Seek Test Error limit exceeded Replace disk drive or media
420505 Bmic Device, Butterfly Seek Test No fibre channel port selected Use a more recent version of diagnostics
420505 Bmic Device, Butterfly Seek Test Could not access file Use a more recent version of diagnostics
420505 Bmic Device, Butterfly Seek Test Invalid access order Select a different access order for this test
420505 Bmic Device, Butterfly Seek Test Invalid parameter list Select different parameters for this test
420710 Bmic Device, Butterfly Seek Test Could not access media Replace disk drive or media
420202 Bmic Device, Butterfly Seek Test Cannot determine bus speed Check that Smart Array firmware and device drivers are up to date
420202 Bmic Device, Butterfly Seek Test Cannot determine bus width Check that Smart Array firmware and device drivers are up to date
420505 Bmic Device, Butterfly Seek Test SCSI command is not supported Use a more recent version of diagnostics
420505 Bmic Device, Butterfly Seek Test SCSI adapter not implemented Use a more recent version of diagnostics
420710 Bmic Device, Butterfly Seek Test Could not transfer SCSI data Check SCSI cables and connectors
420505 Bmic Device, Butterfly Seek Test SCSI device not implemented Use a more recent version of diagnostics
420505 Bmic Device, Butterfly Seek Test Undefined SCSI adapter Use a more recent version of diagnostics
420505 Bmic Device, Butterfly Seek Test Device reported problem Use a more recent version of diagnostics
420505 Bmic Device, Butterfly Seek Test Unknown device type Use a more recent version of diagnostics
420202 Bmic Device, Random Seek Test BMIC driver reported problem Check that Smart Array firmware and device drivers are up to date
420505 Bmic Device, Random Seek Test Cannot open filesystem table Use a more recent version of diagnostics
420303 Bmic Device, Random Seek Test CISS driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Bmic Device, Random Seek Test Driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Bmic Device, Random Seek Test Controller is not supported Check that Smart Array firmware and device drivers are up to date
420710 Bmic Device, Random Seek Test Error limit exceeded Replace disk drive or media
420505 Bmic Device, Random Seek Test No fibre channel port selected Use a more recent version of diagnostics
420505 Bmic Device, Random Seek Test Could not access file Use a more recent version of diagnostics
420505 Bmic Device, Random Seek Test Invalid access order Select a different access order for this test
420505 Bmic Device, Random Seek Test Invalid parameter list Select different parameters for this test
420710 Bmic Device, Random Seek Test Could not access media Replace disk drive or media
420202 Bmic Device, Random Seek Test Cannot determine bus speed Check that Smart Array firmware and device drivers are up to date
420202 Bmic Device, Random Seek Test Cannot determine bus width Check that Smart Array firmware and device drivers are up to date
420505 Bmic Device, Random Seek Test SCSI command is not supported Use a more recent version of diagnostics
420505 Bmic Device, Random Seek Test SCSI adapter not implemented Use a more recent version of diagnostics
420710 Bmic Device, Random Seek Test Could not transfer SCSI data Check SCSI cables and connectors
420505 Bmic Device, Random Seek Test SCSI device not implemented Use a more recent version of diagnostics
420505 Bmic Device, Random Seek Test Undefined SCSI adapter Use a more recent version of diagnostics
420505 Bmic Device, Random Seek Test Device reported problem Use a more recent version of diagnostics
420505 Bmic Device, Random Seek Test Unknown device type Use a more recent version of diagnostics
411402 Ciss Device, Controller Memory, MOVING INV LONG Test The RAID board failed the test. See failure details for specific problem. Controller Needs Rework
410303 Ciss Device, Controller Memory, MOVING INV LONG Test CISS driver reported problem Check that Smart Array firmware and device drivers are up to date
420202 Ciss Device, Controller Memory, MOVING INV LONG Test BMIC driver reported problem Check that Smart Array firmware and device drivers are up to date
420505 Ciss Device, Controller Memory, MOVING INV LONG Test Cannot open filesystem table Use a more recent version of diagnostics
420101 Ciss Device, Controller Memory, MOVING INV LONG Test Driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Ciss Device, Controller Memory, MOVING INV LONG Test Controller is not supported Check that Smart Array firmware and device drivers are up to date
420710 Ciss Device, Controller Memory, MOVING INV LONG Test Error limit exceeded Replace disk drive or media
420505 Ciss Device, Controller Memory, MOVING INV LONG Test No fibre channel port selected Use a more recent version of diagnostics
420505 Ciss Device, Controller Memory, MOVING INV LONG Test Could not access file Use a more recent version of diagnostics
420505 Ciss Device, Controller Memory, MOVING INV LONG Test Invalid access order Select a different access order for this test
420505 Ciss Device, Controller Memory, MOVING INV LONG Test Invalid parameter list Select different parameters for this test
420710 Ciss Device, Controller Memory, MOVING INV LONG Test Could not access media Replace disk drive or media
420202 Ciss Device, Controller Memory, MOVING INV LONG Test Cannot determine bus speed Check that Smart Array firmware and device drivers are up to date
420202 Ciss Device, Controller Memory, MOVING INV LONG Test Cannot determine bus width Check that Smart Array firmware and device drivers are up to date
420505 Ciss Device, Controller Memory, MOVING INV LONG Test SCSI command is not supported Use a more recent version of diagnostics
420505 Ciss Device, Controller Memory, MOVING INV LONG Test SCSI adapter not implemented Use a more recent version of diagnostics
420710 Ciss Device, Controller Memory, MOVING INV LONG Test Could not transfer SCSI data Check SCSI cables and connectors
420505 Ciss Device, Controller Memory, MOVING INV LONG Test SCSI device not implemented Use a more recent version of diagnostics
420505 Ciss Device, Controller Memory, MOVING INV LONG Test Undefined SCSI adapter Use a more recent version of diagnostics
420505 Ciss Device, Controller Memory, MOVING INV LONG Test Device reported problem Use a more recent version of diagnostics
420505 Ciss Device, Controller Memory, MOVING INV LONG Test Unknown device type Use a more recent version of diagnostics
411403 Ciss Device, Controller Memory, MOVING INV TURBO Test The RAID board failed the test. See failure details for specific problem. Controller Needs Rework
410303 Ciss Device, Controller Memory, MOVING INV TURBO Test CISS driver reported problem Check that Smart Array firmware and device drivers are up to date
420202 Ciss Device, Controller Memory, MOVING INV TURBO Test BMIC driver reported problem Check that Smart Array firmware and device drivers are up to date
420505 Ciss Device, Controller Memory, MOVING INV TURBO Test Cannot open filesystem table Use a more recent version of diagnostics
420101 Ciss Device, Controller Memory, MOVING INV TURBO Test Driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Ciss Device, Controller Memory, MOVING INV TURBO Test Controller is not supported Check that Smart Array firmware and device drivers are up to date
420710 Ciss Device, Controller Memory, MOVING INV TURBO Test Error limit exceeded Replace disk drive or media
420505 Ciss Device, Controller Memory, MOVING INV TURBO Test No fibre channel port selected Use a more recent version of diagnostics
420505 Ciss Device, Controller Memory, MOVING INV TURBO Test Could not access file Use a more recent version of diagnostics
420505 Ciss Device, Controller Memory, MOVING INV TURBO Test Invalid access order Select a different access order for this test
420505 Ciss Device, Controller Memory, MOVING INV TURBO Test Invalid parameter list Select different parameters for this test
420710 Ciss Device, Controller Memory, MOVING INV TURBO Test Could not access media Replace disk drive or media
420202 Ciss Device, Controller Memory, MOVING INV TURBO Test Cannot determine bus speed Check that Smart Array firmware and device drivers are up to date
420202 Ciss Device, Controller Memory, MOVING INV TURBO Test Cannot determine bus width Check that Smart Array firmware and device drivers are up to date
420505 Ciss Device, Controller Memory, MOVING INV TURBO Test SCSI command is not supported Use a more recent version of diagnostics
420505 Ciss Device, Controller Memory, MOVING INV TURBO Test SCSI adapter not implemented Use a more recent version of diagnostics
420710 Ciss Device, Controller Memory, MOVING INV TURBO Test Could not transfer SCSI data Check SCSI cables and connectors
420505 Ciss Device, Controller Memory, MOVING INV TURBO Test SCSI device not implemented Use a more recent version of diagnostics
420505 Ciss Device, Controller Memory, MOVING INV TURBO Test Undefined SCSI adapter Use a more recent version of diagnostics
420505 Ciss Device, Controller Memory, MOVING INV TURBO Test Device reported problem Use a more recent version of diagnostics
420505 Ciss Device, Controller Memory, MOVING INV TURBO Test Unknown device type Use a more recent version of diagnostics
411404 Ciss Device, Controller Memory, FBT Test The RAID board failed the test. See failure details for specific problem. Controller Needs Rework
410303 Ciss Device, Controller Memory, FBT Test CISS driver reported problem Check that Smart Array firmware and device drivers are up to date
420202 Ciss Device, Controller Memory, FBT Test BMIC driver reported problem Check that Smart Array firmware and device drivers are up to date
420505 Ciss Device, Controller Memory, FBT Test Cannot open filesystem table Use a more recent version of diagnostics
420101 Ciss Device, Controller Memory, FBT Test Driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Ciss Device, Controller Memory, FBT Test Controller is not supported Check that Smart Array firmware and device drivers are up to date
420710 Ciss Device, Controller Memory, FBT Test Error limit exceeded Replace disk drive or media
420505 Ciss Device, Controller Memory, FBT Test No fibre channel port selected Use a more recent version of diagnostics
420505 Ciss Device, Controller Memory, FBT Test Could not access file Use a more recent version of diagnostics
420505 Ciss Device, Controller Memory, FBT Test Invalid access order Select a different access order for this test
420505 Ciss Device, Controller Memory, FBT Test Invalid parameter list Select different parameters for this test
420710 Ciss Device, Controller Memory, FBT Test Could not access media Replace disk drive or media
420202 Ciss Device, Controller Memory, FBT Test Cannot determine bus speed Check that Smart Array firmware and device drivers are up to date
420202 Ciss Device, Controller Memory, FBT Test Cannot determine bus width Check that Smart Array firmware and device drivers are up to date
420505 Ciss Device, Controller Memory, FBT Test SCSI command is not supported Use a more recent version of diagnostics
420505 Ciss Device, Controller Memory, FBT Test SCSI adapter not implemented Use a more recent version of diagnostics
420710 Ciss Device, Controller Memory, FBT Test Could not transfer SCSI data Check SCSI cables and connectors
420505 Ciss Device, Controller Memory, FBT Test SCSI device not implemented Use a more recent version of diagnostics
420505 Ciss Device, Controller Memory, FBT Test Undefined SCSI adapter Use a more recent version of diagnostics
420505 Ciss Device, Controller Memory, FBT Test Device reported problem Use a more recent version of diagnostics
420505 Ciss Device, Controller Memory, FBT Test Unknown device type Use a more recent version of diagnostics
411406 Ciss Device, Cache, Moving INV Long Test The RAID board failed the test. See failure details for specific problem. Controller Needs Rework
410303 Ciss Device, Cache, Moving INV Long Test CISS driver reported problem Check that Smart Array firmware and device drivers are up to date
420202 Ciss Device, Cache, Moving INV Long Test BMIC driver reported problem Check that Smart Array firmware and device drivers are up to date
420505 Ciss Device, Cache, Moving INV Long Test Cannot open filesystem table Use a more recent version of diagnostics
420101 Ciss Device, Cache, Moving INV Long Test Driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Ciss Device, Cache, Moving INV Long Test Controller is not supported Check that Smart Array firmware and device drivers are up to date
420710 Ciss Device, Cache, Moving INV Long Test Error limit exceeded Replace disk drive or media
420505 Ciss Device, Cache, Moving INV Long Test No fibre channel port selected Use a more recent version of diagnostics
420505 Ciss Device, Cache, Moving INV Long Test Could not access file Use a more recent version of diagnostics
420505 Ciss Device, Cache, Moving INV Long Test Invalid access order Select a different access order for this test
420505 Ciss Device, Cache, Moving INV Long Test Invalid parameter list Select different parameters for this test
420710 Ciss Device, Cache, Moving INV Long Test Could not access media Replace disk drive or media
420202 Ciss Device, Cache, Moving INV Long Test Cannot determine bus speed Check that Smart Array firmware and device drivers are up to date
420202 Ciss Device, Cache, Moving INV Long Test Cannot determine bus width Check that Smart Array firmware and device drivers are up to date
420505 Ciss Device, Cache, Moving INV Long Test SCSI command is not supported Use a more recent version of diagnostics
420505 Ciss Device, Cache, Moving INV Long Test SCSI adapter not implemented Use a more recent version of diagnostics
420710 Ciss Device, Cache, Moving INV Long Test Could not transfer SCSI data Check SCSI cables and connectors
420505 Ciss Device, Cache, Moving INV Long Test SCSI device not implemented Use a more recent version of diagnostics
420505 Ciss Device, Cache, Moving INV Long Test Undefined SCSI adapter Use a more recent version of diagnostics
420505 Ciss Device, Cache, Moving INV Long Test Device reported problem Use a more recent version of diagnostics
420505 Ciss Device, Cache, Moving INV Long Test Unknown device type Use a more recent version of diagnostics
411407 Ciss Device, Cache, Moving INV Turbo Test The RAID board failed the test. See failure details for specific problem. Controller Needs Rework
410303 Ciss Device, Cache, Moving INV Turbo Test CISS driver reported problem Check that Smart Array firmware and device drivers are up to date
420202 Ciss Device, Cache, Moving INV Turbo Test BMIC driver reported problem Check that Smart Array firmware and device drivers are up to date
420505 Ciss Device, Cache, Moving INV Turbo Test Cannot open filesystem table Use a more recent version of diagnostics
420101 Ciss Device, Cache, Moving INV Turbo Test Driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Ciss Device, Cache, Moving INV Turbo Test Controller is not supported Check that Smart Array firmware and device drivers are up to date
420710 Ciss Device, Cache, Moving INV Turbo Test Error limit exceeded Replace disk drive or media
420505 Ciss Device, Cache, Moving INV Turbo Test No fibre channel port selected Use a more recent version of diagnostics
420505 Ciss Device, Cache, Moving INV Turbo Test Could not access file Use a more recent version of diagnostics
420505 Ciss Device, Cache, Moving INV Turbo Test Invalid access order Select a different access order for this test
420505 Ciss Device, Cache, Moving INV Turbo Test Invalid parameter list Select different parameters for this test
420710 Ciss Device, Cache, Moving INV Turbo Test Could not access media Replace disk drive or media
420202 Ciss Device, Cache, Moving INV Turbo Test Cannot determine bus speed Check that Smart Array firmware and device drivers are up to date
420202 Ciss Device, Cache, Moving INV Turbo Test Cannot determine bus width Check that Smart Array firmware and device drivers are up to date
420505 Ciss Device, Cache, Moving INV Turbo Test SCSI command is not supported Use a more recent version of diagnostics
420505 Ciss Device, Cache, Moving INV Turbo Test SCSI adapter not implemented Use a more recent version of diagnostics
420710 Ciss Device, Cache, Moving INV Turbo Test Could not transfer SCSI data Check SCSI cables and connectors
420505 Ciss Device, Cache, Moving INV Turbo Test SCSI device not implemented Use a more recent version of diagnostics
420505 Ciss Device, Cache, Moving INV Turbo Test Undefined SCSI adapter Use a more recent version of diagnostics
420505 Ciss Device, Cache, Moving INV Turbo Test Device reported problem Use a more recent version of diagnostics
420505 Ciss Device, Cache, Moving INV Turbo Test Unknown device type Use a more recent version of diagnostics
411408 Ciss Device, Cache, FBT Test The RAID board failed the test. See failure details for specific problem. Controller Needs Rework
410303 Ciss Device, Cache, FBT Test CISS driver reported problem Check that Smart Array firmware and device drivers are up to date
420202 Ciss Device, Cache, FBT Test BMIC driver reported problem Check that Smart Array firmware and device drivers are up to date
420505 Ciss Device, Cache, FBT Test Cannot open filesystem table Use a more recent version of diagnostics
420101 Ciss Device, Cache, FBT Test Driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Ciss Device, Cache, FBT Test Controller is not supported Check that Smart Array firmware and device drivers are up to date
420710 Ciss Device, Cache, FBT Test Error limit exceeded Replace disk drive or media
420505 Ciss Device, Cache, FBT Test No fibre channel port selected Use a more recent version of diagnostics
420505 Ciss Device, Cache, FBT Test Could not access file Use a more recent version of diagnostics
420505 Ciss Device, Cache, FBT Test Invalid access order Select a different access order for this test
420505 Ciss Device, Cache, FBT Test Invalid parameter list Select different parameters for this test
420710 Ciss Device, Cache, FBT Test Could not access media Replace disk drive or media
420202 Ciss Device, Cache, FBT Test Cannot determine bus speed Check that Smart Array firmware and device drivers are up to date
420202 Ciss Device, Cache, FBT Test Cannot determine bus width Check that Smart Array firmware and device drivers are up to date
420505 Ciss Device, Cache, FBT Test SCSI command is not supported Use a more recent version of diagnostics
420505 Ciss Device, Cache, FBT Test SCSI adapter not implemented Use a more recent version of diagnostics
420710 Ciss Device, Cache, FBT Test Could not transfer SCSI data Check SCSI cables and connectors
420505 Ciss Device, Cache, FBT Test SCSI device not implemented Use a more recent version of diagnostics
420505 Ciss Device, Cache, FBT Test Undefined SCSI adapter Use a more recent version of diagnostics
420505 Ciss Device, Cache, FBT Test Device reported problem Use a more recent version of diagnostics
420505 Ciss Device, Cache, FBT Test Unknown device type Use a more recent version of diagnostics
411409 Ciss Device, Cache, Random Address Bus Master Test The RAID board failed the test. See failure details for specific problem. Controller Needs Rework
410303 Ciss Device, Cache, Random Address Bus Master Test CISS driver reported problem Check that Smart Array firmware and device drivers are up to date
420202 Ciss Device, Cache, Random Address Bus Master Test BMIC driver reported problem Check that Smart Array firmware and device drivers are up to date
420505 Ciss Device, Cache, Random Address Bus Master Test Cannot open filesystem table Use a more recent version of diagnostics
420101 Ciss Device, Cache, Random Address Bus Master Test Driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Ciss Device, Cache, Random Address Bus Master Test Controller is not supported Check that Smart Array firmware and device drivers are up to date
420710 Ciss Device, Cache, Random Address Bus Master Test Error limit exceeded Replace disk drive or media
420505 Ciss Device, Cache, Random Address Bus Master Test No fibre channel port selected Use a more recent version of diagnostics
420505 Ciss Device, Cache, Random Address Bus Master Test Could not access file Use a more recent version of diagnostics
420505 Ciss Device, Cache, Random Address Bus Master Test Invalid access order Select a different access order for this test
420505 Ciss Device, Cache, Random Address Bus Master Test Invalid parameter list Select different parameters for this test
420710 Ciss Device, Cache, Random Address Bus Master Test Could not access media Replace disk drive or media
420202 Ciss Device, Cache, Random Address Bus Master Test Cannot determine bus speed Check that Smart Array firmware and device drivers are up to date
420202 Ciss Device, Cache, Random Address Bus Master Test Cannot determine bus width Check that Smart Array firmware and device drivers are up to date
420505 Ciss Device, Cache, Random Address Bus Master Test SCSI command is not supported Use a more recent version of diagnostics
420505 Ciss Device, Cache, Random Address Bus Master Test SCSI adapter not implemented Use a more recent version of diagnostics
420710 Ciss Device, Cache, Random Address Bus Master Test Could not transfer SCSI data Check SCSI cables and connectors
420505 Ciss Device, Cache, Random Address Bus Master Test SCSI device not implemented Use a more recent version of diagnostics
420505 Ciss Device, Cache, Random Address Bus Master Test Undefined SCSI adapter Use a more recent version of diagnostics
420505 Ciss Device, Cache, Random Address Bus Master Test Device reported problem Use a more recent version of diagnostics
420505 Ciss Device, Cache, Random Address Bus Master Test Unknown device type Use a more recent version of diagnostics
411410 Ciss Device, Cache, Address Bus Master Test The RAID board failed the test. See failure details for specific problem. Controller Needs Rework
410303 Ciss Device, Cache, Address Bus Master Test CISS driver reported problem Check that Smart Array firmware and device drivers are up to date
420202 Ciss Device, Cache, Address Bus Master Test BMIC driver reported problem Check that Smart Array firmware and device drivers are up to date
420505 Ciss Device, Cache, Address Bus Master Test Cannot open filesystem table Use a more recent version of diagnostics
420101 Ciss Device, Cache, Address Bus Master Test Driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Ciss Device, Cache, Address Bus Master Test Controller is not supported Check that Smart Array firmware and device drivers are up to date
420710 Ciss Device, Cache, Address Bus Master Test Error limit exceeded Replace disk drive or media
420505 Ciss Device, Cache, Address Bus Master Test No fibre channel port selected Use a more recent version of diagnostics
420505 Ciss Device, Cache, Address Bus Master Test Could not access file Use a more recent version of diagnostics
420505 Ciss Device, Cache, Address Bus Master Test Invalid access order Select a different access order for this test
420505 Ciss Device, Cache, Address Bus Master Test Invalid parameter list Select different parameters for this test
420710 Ciss Device, Cache, Address Bus Master Test Could not access media Replace disk drive or media
420202 Ciss Device, Cache, Address Bus Master Test Cannot determine bus speed Check that Smart Array firmware and device drivers are up to date
420202 Ciss Device, Cache, Address Bus Master Test Cannot determine bus width Check that Smart Array firmware and device drivers are up to date
420505 Ciss Device, Cache, Address Bus Master Test SCSI command is not supported Use a more recent version of diagnostics
420505 Ciss Device, Cache, Address Bus Master Test SCSI adapter not implemented Use a more recent version of diagnostics
420710 Ciss Device, Cache, Address Bus Master Test Could not transfer SCSI data Check SCSI cables and connectors
420505 Ciss Device, Cache, Address Bus Master Test SCSI device not implemented Use a more recent version of diagnostics
420505 Ciss Device, Cache, Address Bus Master Test Undefined SCSI adapter Use a more recent version of diagnostics
420505 Ciss Device, Cache, Address Bus Master Test Device reported problem Use a more recent version of diagnostics
420505 Ciss Device, Cache, Address Bus Master Test Unknown device type Use a more recent version of diagnostics
411412 Ciss Device, Data Retention, Battery On Data Write Test The RAID board failed the test. See failure details for specific problem. Controller Needs Rework
410303 Ciss Device, Data Retention, Battery On Data Write Test CISS driver reported problem Check that Smart Array firmware and device drivers are up to date
420202 Ciss Device, Data Retention, Battery On Data Write Test BMIC driver reported problem Check that Smart Array firmware and device drivers are up to date
420505 Ciss Device, Data Retention, Battery On Data Write Test Cannot open filesystem table Use a more recent version of diagnostics
420101 Ciss Device, Data Retention, Battery On Data Write Test Driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Ciss Device, Data Retention, Battery On Data Write Test Controller is not supported Check that Smart Array firmware and device drivers are up to date
420710 Ciss Device, Data Retention, Battery On Data Write Test Error limit exceeded Replace disk drive or media
420505 Ciss Device, Data Retention, Battery On Data Write Test No fibre channel port selected Use a more recent version of diagnostics
420505 Ciss Device, Data Retention, Battery On Data Write Test Could not access file Use a more recent version of diagnostics
420505 Ciss Device, Data Retention, Battery On Data Write Test Invalid access order Select a different access order for this test
420505 Ciss Device, Data Retention, Battery On Data Write Test Invalid parameter list Select different parameters for this test
420710 Ciss Device, Data Retention, Battery On Data Write Test Could not access media Replace disk drive or media
420202 Ciss Device, Data Retention, Battery On Data Write Test Cannot determine bus speed Check that Smart Array firmware and device drivers are up to date
420202 Ciss Device, Data Retention, Battery On Data Write Test Cannot determine bus width Check that Smart Array firmware and device drivers are up to date
420505 Ciss Device, Data Retention, Battery On Data Write Test SCSI command is not supported Use a more recent version of diagnostics
420505 Ciss Device, Data Retention, Battery On Data Write Test SCSI adapter not implemented Use a more recent version of diagnostics
420710 Ciss Device, Data Retention, Battery On Data Write Test Could not transfer SCSI data Check SCSI cables and connectors
420505 Ciss Device, Data Retention, Battery On Data Write Test SCSI device not implemented Use a more recent version of diagnostics
420505 Ciss Device, Data Retention, Battery On Data Write Test Undefined SCSI adapter Use a more recent version of diagnostics
420505 Ciss Device, Data Retention, Battery On Data Write Test Device reported problem Use a more recent version of diagnostics
420505 Ciss Device, Data Retention, Battery On Data Write Test Unknown device type Use a more recent version of diagnostics
411413 Ciss Device, Data Retention, Verify Test The RAID board failed the test. See failure details for specific problem. Controller Needs Rework
410303 Ciss Device, Data Retention, Verify Test CISS driver reported problem Check that Smart Array firmware and device drivers are up to date
420202 Ciss Device, Data Retention, Verify Test BMIC driver reported problem Check that Smart Array firmware and device drivers are up to date
420505 Ciss Device, Data Retention, Verify Test Cannot open filesystem table Use a more recent version of diagnostics
420101 Ciss Device, Data Retention, Verify Test Driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Ciss Device, Data Retention, Verify Test Controller is not supported Check that Smart Array firmware and device drivers are up to date
420710 Ciss Device, Data Retention, Verify Test Error limit exceeded Replace disk drive or media
420505 Ciss Device, Data Retention, Verify Test No fibre channel port selected Use a more recent version of diagnostics
420505 Ciss Device, Data Retention, Verify Test Could not access file Use a more recent version of diagnostics
420505 Ciss Device, Data Retention, Verify Test Invalid access order Select a different access order for this test
420505 Ciss Device, Data Retention, Verify Test Invalid parameter list Select different parameters for this test
420710 Ciss Device, Data Retention, Verify Test Could not access media Replace disk drive or media
420202 Ciss Device, Data Retention, Verify Test Cannot determine bus speed Check that Smart Array firmware and device drivers are up to date
420202 Ciss Device, Data Retention, Verify Test Cannot determine bus width Check that Smart Array firmware and device drivers are up to date
420505 Ciss Device, Data Retention, Verify Test SCSI command is not supported Use a more recent version of diagnostics
420505 Ciss Device, Data Retention, Verify Test SCSI adapter not implemented Use a more recent version of diagnostics
420710 Ciss Device, Data Retention, Verify Test Could not transfer SCSI data Check SCSI cables and connectors
420505 Ciss Device, Data Retention, Verify Test SCSI device not implemented Use a more recent version of diagnostics
420505 Ciss Device, Data Retention, Verify Test Undefined SCSI adapter Use a more recent version of diagnostics
420505 Ciss Device, Data Retention, Verify Test Device reported problem Use a more recent version of diagnostics
420505 Ciss Device, Data Retention, Verify Test Unknown device type Use a more recent version of diagnostics
411414 Ciss Device, Data Non-Retention, Verify Test The RAID board failed the test. See failure details for specific problem. Controller Needs Rework
410303 Ciss Device, Data Non-Retention, Verify Test CISS driver reported problem Check that Smart Array firmware and device drivers are up to date
420202 Ciss Device, Data Non-Retention, Verify Test BMIC driver reported problem Check that Smart Array firmware and device drivers are up to date
420505 Ciss Device, Data Non-Retention, Verify Test Cannot open filesystem table Use a more recent version of diagnostics
420101 Ciss Device, Data Non-Retention, Verify Test Driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Ciss Device, Data Non-Retention, Verify Test Controller is not supported Check that Smart Array firmware and device drivers are up to date
420710 Ciss Device, Data Non-Retention, Verify Test Error limit exceeded Replace disk drive or media
420505 Ciss Device, Data Non-Retention, Verify Test No fibre channel port selected Use a more recent version of diagnostics
420505 Ciss Device, Data Non-Retention, Verify Test Could not access file Use a more recent version of diagnostics
420505 Ciss Device, Data Non-Retention, Verify Test Invalid access order Select a different access order for this test
420505 Ciss Device, Data Non-Retention, Verify Test Invalid parameter list Select different parameters for this test
420710 Ciss Device, Data Non-Retention, Verify Test Could not access media Replace disk drive or media
420202 Ciss Device, Data Non-Retention, Verify Test Cannot determine bus speed Check that Smart Array firmware and device drivers are up to date
420202 Ciss Device, Data Non-Retention, Verify Test Cannot determine bus width Check that Smart Array firmware and device drivers are up to date
420505 Ciss Device, Data Non-Retention, Verify Test SCSI command is not supported Use a more recent version of diagnostics
420505 Ciss Device, Data Non-Retention, Verify Test SCSI adapter not implemented Use a more recent version of diagnostics
420710 Ciss Device, Data Non-Retention, Verify Test Could not transfer SCSI data Check SCSI cables and connectors
420505 Ciss Device, Data Non-Retention, Verify Test SCSI device not implemented Use a more recent version of diagnostics
420505 Ciss Device, Data Non-Retention, Verify Test Undefined SCSI adapter Use a more recent version of diagnostics
420505 Ciss Device, Data Non-Retention, Verify Test Device reported problem Use a more recent version of diagnostics
420505 Ciss Device, Data Non-Retention, Verify Test Unknown device type Use a more recent version of diagnostics
411417 Ciss Device, Data Retention, Set Battery Off Test The RAID board failed the test. See failure details for specific problem. Controller Needs Rework
410303 Ciss Device, Data Retention, Set Battery Off Test CISS driver reported problem Check that Smart Array firmware and device drivers are up to date
420202 Ciss Device, Data Retention, Set Battery Off Test BMIC driver reported problem Check that Smart Array firmware and device drivers are up to date
420505 Ciss Device, Data Retention, Set Battery Off Test Cannot open filesystem table Use a more recent version of diagnostics
420101 Ciss Device, Data Retention, Set Battery Off Test Driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Ciss Device, Data Retention, Set Battery Off Test Controller is not supported Check that Smart Array firmware and device drivers are up to date
420710 Ciss Device, Data Retention, Set Battery Off Test Error limit exceeded Replace disk drive or media
420505 Ciss Device, Data Retention, Set Battery Off Test No fibre channel port selected Use a more recent version of diagnostics
420505 Ciss Device, Data Retention, Set Battery Off Test Could not access file Use a more recent version of diagnostics
420505 Ciss Device, Data Retention, Set Battery Off Test Invalid access order Select a different access order for this test
420505 Ciss Device, Data Retention, Set Battery Off Test Invalid parameter list Select different parameters for this test
420710 Ciss Device, Data Retention, Set Battery Off Test Could not access media Replace disk drive or media
420202 Ciss Device, Data Retention, Set Battery Off Test Cannot determine bus speed Check that Smart Array firmware and device drivers are up to date
420202 Ciss Device, Data Retention, Set Battery Off Test Cannot determine bus width Check that Smart Array firmware and device drivers are up to date
420505 Ciss Device, Data Retention, Set Battery Off Test SCSI command is not supported Use a more recent version of diagnostics
420505 Ciss Device, Data Retention, Set Battery Off Test SCSI adapter not implemented Use a more recent version of diagnostics
420710 Ciss Device, Data Retention, Set Battery Off Test Could not transfer SCSI data Check SCSI cables and connectors
420505 Ciss Device, Data Retention, Set Battery Off Test SCSI device not implemented Use a more recent version of diagnostics
420505 Ciss Device, Data Retention, Set Battery Off Test Undefined SCSI adapter Use a more recent version of diagnostics
420505 Ciss Device, Data Retention, Set Battery Off Test Device reported problem Use a more recent version of diagnostics
420505 Ciss Device, Data Retention, Set Battery Off Test Unknown device type Use a more recent version of diagnostics
411419 Ciss Device, Loop Back, 1/2 Subtest The RAID board failed the test. See failure details for specific problem. Controller Needs Rework
410303 Ciss Device, Loop Back, 1/2 Subtest CISS driver reported problem Check that Smart Array firmware and device drivers are up to date
420202 Ciss Device, Loop Back, 1/2 Subtest BMIC driver reported problem Check that Smart Array firmware and device drivers are up to date
420505 Ciss Device, Loop Back, 1/2 Subtest Cannot open filesystem table Use a more recent version of diagnostics
420101 Ciss Device, Loop Back, 1/2 Subtest Driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Ciss Device, Loop Back, 1/2 Subtest Controller is not supported Check that Smart Array firmware and device drivers are up to date
420710 Ciss Device, Loop Back, 1/2 Subtest Error limit exceeded Replace disk drive or media
420505 Ciss Device, Loop Back, 1/2 Subtest No fibre channel port selected Use a more recent version of diagnostics
420505 Ciss Device, Loop Back, 1/2 Subtest Could not access file Use a more recent version of diagnostics
420505 Ciss Device, Loop Back, 1/2 Subtest Invalid access order Select a different access order for this test
420505 Ciss Device, Loop Back, 1/2 Subtest Invalid parameter list Select different parameters for this test
420710 Ciss Device, Loop Back, 1/2 Subtest Could not access media Replace disk drive or media
420202 Ciss Device, Loop Back, 1/2 Subtest Cannot determine bus speed Check that Smart Array firmware and device drivers are up to date
420202 Ciss Device, Loop Back, 1/2 Subtest Cannot determine bus width Check that Smart Array firmware and device drivers are up to date
420505 Ciss Device, Loop Back, 1/2 Subtest SCSI command is not supported Use a more recent version of diagnostics
420505 Ciss Device, Loop Back, 1/2 Subtest SCSI adapter not implemented Use a more recent version of diagnostics
420710 Ciss Device, Loop Back, 1/2 Subtest Could not transfer SCSI data Check SCSI cables and connectors
420505 Ciss Device, Loop Back, 1/2 Subtest SCSI device not implemented Use a more recent version of diagnostics
420505 Ciss Device, Loop Back, 1/2 Subtest Undefined SCSI adapter Use a more recent version of diagnostics
420505 Ciss Device, Loop Back, 1/2 Subtest Device reported problem Use a more recent version of diagnostics
420505 Ciss Device, Loop Back, 1/2 Subtest Unknown device type Use a more recent version of diagnostics
410303 Ciss Device, Controller LED Test CISS driver reported problem Check that Smart Array firmware and device drivers are up to date
411423 Ciss Device, Controller LED Test The RAID board failed the test. See failure details for specific problem. Controller Needs Rework
420202 Ciss Device, Controller LED Test BMIC driver reported problem Check that Smart Array firmware and device drivers are up to date
420505 Ciss Device, Controller LED Test Cannot open filesystem table Use a more recent version of diagnostics
420101 Ciss Device, Controller LED Test Driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Ciss Device, Controller LED Test Controller is not supported Check that Smart Array firmware and device drivers are up to date
420710 Ciss Device, Controller LED Test Error limit exceeded Replace disk drive or media
420505 Ciss Device, Controller LED Test No fibre channel port selected Use a more recent version of diagnostics
420505 Ciss Device, Controller LED Test Could not access file Use a more recent version of diagnostics
420505 Ciss Device, Controller LED Test Invalid access order Select a different access order for this test
420505 Ciss Device, Controller LED Test Invalid parameter list Select different parameters for this test
420710 Ciss Device, Controller LED Test Could not access media Replace disk drive or media
420202 Ciss Device, Controller LED Test Cannot determine bus speed Check that Smart Array firmware and device drivers are up to date
420202 Ciss Device, Controller LED Test Cannot determine bus width Check that Smart Array firmware and device drivers are up to date
420505 Ciss Device, Controller LED Test SCSI command is not supported Use a more recent version of diagnostics
420505 Ciss Device, Controller LED Test SCSI adapter not implemented Use a more recent version of diagnostics
420710 Ciss Device, Controller LED Test Could not transfer SCSI data Check SCSI cables and connectors
420505 Ciss Device, Controller LED Test SCSI device not implemented Use a more recent version of diagnostics
420505 Ciss Device, Controller LED Test Undefined SCSI adapter Use a more recent version of diagnostics
420505 Ciss Device, Controller LED Test Device reported problem Use a more recent version of diagnostics
420505 Ciss Device, Controller LED Test Unknown device type Use a more recent version of diagnostics
411424 Ciss Device, NVRAM Local Host Consistency Test The RAID board failed the test. See failure details for specific problem. Controller Needs Rework
410303 Ciss Device, NVRAM Local Host Consistency Test CISS driver reported problem Check that Smart Array firmware and device drivers are up to date
420202 Ciss Device, NVRAM Local Host Consistency Test BMIC driver reported problem Check that Smart Array firmware and device drivers are up to date
420505 Ciss Device, NVRAM Local Host Consistency Test Cannot open filesystem table Use a more recent version of diagnostics
420101 Ciss Device, NVRAM Local Host Consistency Test Driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Ciss Device, NVRAM Local Host Consistency Test Controller is not supported Check that Smart Array firmware and device drivers are up to date
420710 Ciss Device, NVRAM Local Host Consistency Test Error limit exceeded Replace disk drive or media
420505 Ciss Device, NVRAM Local Host Consistency Test No fibre channel port selected Use a more recent version of diagnostics
420505 Ciss Device, NVRAM Local Host Consistency Test Could not access file Use a more recent version of diagnostics
420505 Ciss Device, NVRAM Local Host Consistency Test Invalid access order Select a different access order for this test
420505 Ciss Device, NVRAM Local Host Consistency Test Invalid parameter list Select different parameters for this test
420710 Ciss Device, NVRAM Local Host Consistency Test Could not access media Replace disk drive or media
420202 Ciss Device, NVRAM Local Host Consistency Test Cannot determine bus speed Check that Smart Array firmware and device drivers are up to date
420202 Ciss Device, NVRAM Local Host Consistency Test Cannot determine bus width Check that Smart Array firmware and device drivers are up to date
420505 Ciss Device, NVRAM Local Host Consistency Test SCSI command is not supported Use a more recent version of diagnostics
420505 Ciss Device, NVRAM Local Host Consistency Test SCSI adapter not implemented Use a more recent version of diagnostics
420710 Ciss Device, NVRAM Local Host Consistency Test Could not transfer SCSI data Check SCSI cables and connectors
420505 Ciss Device, NVRAM Local Host Consistency Test SCSI device not implemented Use a more recent version of diagnostics
420505 Ciss Device, NVRAM Local Host Consistency Test Undefined SCSI adapter Use a more recent version of diagnostics
420505 Ciss Device, NVRAM Local Host Consistency Test Device reported problem Use a more recent version of diagnostics
420505 Ciss Device, NVRAM Local Host Consistency Test Unknown device type Use a more recent version of diagnostics
420202 Ciss Device, SCSI Self Test BMIC driver reported problem Check that Smart Array firmware and device drivers are up to date
420505 Ciss Device, SCSI Self Test Cannot open filesystem table Use a more recent version of diagnostics
420303 Ciss Device, SCSI Self Test CISS driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Ciss Device, SCSI Self Test Driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Ciss Device, SCSI Self Test Controller is not supported Check that Smart Array firmware and device drivers are up to date
420710 Ciss Device, SCSI Self Test Error limit exceeded Replace disk drive or media
420505 Ciss Device, SCSI Self Test No fibre channel port selected Use a more recent version of diagnostics
420505 Ciss Device, SCSI Self Test Could not access file Use a more recent version of diagnostics
420505 Ciss Device, SCSI Self Test Invalid access order Select a different access order for this test
420505 Ciss Device, SCSI Self Test Invalid parameter list Select different parameters for this test
420710 Ciss Device, SCSI Self Test Could not access media Replace disk drive or media
420202 Ciss Device, SCSI Self Test Cannot determine bus speed Check that Smart Array firmware and device drivers are up to date
420202 Ciss Device, SCSI Self Test Cannot determine bus width Check that Smart Array firmware and device drivers are up to date
420505 Ciss Device, SCSI Self Test SCSI command is not supported Use a more recent version of diagnostics
420505 Ciss Device, SCSI Self Test SCSI adapter not implemented Use a more recent version of diagnostics
420710 Ciss Device, SCSI Self Test Could not transfer SCSI data Check SCSI cables and connectors
420505 Ciss Device, SCSI Self Test SCSI device not implemented Use a more recent version of diagnostics
420505 Ciss Device, SCSI Self Test Undefined SCSI adapter Use a more recent version of diagnostics
420505 Ciss Device, SCSI Self Test Device reported problem Use a more recent version of diagnostics
420505 Ciss Device, SCSI Self Test Unknown device type Use a more recent version of diagnostics
420202 Ciss Device, Bus Speed Test BMIC driver reported problem Check that Smart Array firmware and device drivers are up to date
420505 Ciss Device, Bus Speed Test Cannot open filesystem table Use a more recent version of diagnostics
420303 Ciss Device, Bus Speed Test CISS driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Ciss Device, Bus Speed Test Driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Ciss Device, Bus Speed Test Controller is not supported Check that Smart Array firmware and device drivers are up to date
420710 Ciss Device, Bus Speed Test Error limit exceeded Replace disk drive or media
420505 Ciss Device, Bus Speed Test No fibre channel port selected Use a more recent version of diagnostics
420505 Ciss Device, Bus Speed Test Could not access file Use a more recent version of diagnostics
420505 Ciss Device, Bus Speed Test Invalid access order Select a different access order for this test
420505 Ciss Device, Bus Speed Test Invalid parameter list Select different parameters for this test
420710 Ciss Device, Bus Speed Test Could not access media Replace disk drive or media
420202 Ciss Device, Bus Speed Test Cannot determine bus speed Check that Smart Array firmware and device drivers are up to date
420202 Ciss Device, Bus Speed Test Cannot determine bus width Check that Smart Array firmware and device drivers are up to date
420505 Ciss Device, Bus Speed Test SCSI command is not supported Use a more recent version of diagnostics
420505 Ciss Device, Bus Speed Test SCSI adapter not implemented Use a more recent version of diagnostics
420710 Ciss Device, Bus Speed Test Could not transfer SCSI data Check SCSI cables and connectors
420505 Ciss Device, Bus Speed Test SCSI device not implemented Use a more recent version of diagnostics
420505 Ciss Device, Bus Speed Test Undefined SCSI adapter Use a more recent version of diagnostics
420505 Ciss Device, Bus Speed Test Device reported problem Use a more recent version of diagnostics
420505 Ciss Device, Bus Speed Test Unknown device type Use a more recent version of diagnostics
420202 Ciss Device, Sequential Verify Test BMIC driver reported problem Check that Smart Array firmware and device drivers are up to date
420505 Ciss Device, Sequential Verify Test Cannot open filesystem table Use a more recent version of diagnostics
420303 Ciss Device, Sequential Verify Test CISS driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Ciss Device, Sequential Verify Test Driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Ciss Device, Sequential Verify Test Controller is not supported Check that Smart Array firmware and device drivers are up to date
420710 Ciss Device, Sequential Verify Test Error limit exceeded Replace disk drive or media
420505 Ciss Device, Sequential Verify Test No fibre channel port selected Use a more recent version of diagnostics
420505 Ciss Device, Sequential Verify Test Could not access file Use a more recent version of diagnostics
420505 Ciss Device, Sequential Verify Test Invalid access order Select a different access order for this test
420505 Ciss Device, Sequential Verify Test Invalid parameter list Select different parameters for this test
420710 Ciss Device, Sequential Verify Test Could not access media Replace disk drive or media
420202 Ciss Device, Sequential Verify Test Cannot determine bus speed Check that Smart Array firmware and device drivers are up to date
420202 Ciss Device, Sequential Verify Test Cannot determine bus width Check that Smart Array firmware and device drivers are up to date
420505 Ciss Device, Sequential Verify Test SCSI command is not supported Use a more recent version of diagnostics
420505 Ciss Device, Sequential Verify Test SCSI adapter not implemented Use a more recent version of diagnostics
420710 Ciss Device, Sequential Verify Test Could not transfer SCSI data Check SCSI cables and connectors
420505 Ciss Device, Sequential Verify Test SCSI device not implemented Use a more recent version of diagnostics
420505 Ciss Device, Sequential Verify Test Undefined SCSI adapter Use a more recent version of diagnostics
420505 Ciss Device, Sequential Verify Test Device reported problem Use a more recent version of diagnostics
420505 Ciss Device, Sequential Verify Test Unknown device type Use a more recent version of diagnostics
420202 Ciss Device, Sequential Read Test BMIC driver reported problem Check that Smart Array firmware and device drivers are up to date
420505 Ciss Device, Sequential Read Test Cannot open filesystem table Use a more recent version of diagnostics
420303 Ciss Device, Sequential Read Test CISS driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Ciss Device, Sequential Read Test Driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Ciss Device, Sequential Read Test Controller is not supported Check that Smart Array firmware and device drivers are up to date
420710 Ciss Device, Sequential Read Test Error limit exceeded Replace disk drive or media
420505 Ciss Device, Sequential Read Test No fibre channel port selected Use a more recent version of diagnostics
420505 Ciss Device, Sequential Read Test Could not access file Use a more recent version of diagnostics
420505 Ciss Device, Sequential Read Test Invalid access order Select a different access order for this test
420505 Ciss Device, Sequential Read Test Invalid parameter list Select different parameters for this test
420710 Ciss Device, Sequential Read Test Could not access media Replace disk drive or media
420202 Ciss Device, Sequential Read Test Cannot determine bus speed Check that Smart Array firmware and device drivers are up to date
420202 Ciss Device, Sequential Read Test Cannot determine bus width Check that Smart Array firmware and device drivers are up to date
420505 Ciss Device, Sequential Read Test SCSI command is not supported Use a more recent version of diagnostics
420505 Ciss Device, Sequential Read Test SCSI adapter not implemented Use a more recent version of diagnostics
420710 Ciss Device, Sequential Read Test Could not transfer SCSI data Check SCSI cables and connectors
420505 Ciss Device, Sequential Read Test SCSI device not implemented Use a more recent version of diagnostics
420505 Ciss Device, Sequential Read Test Undefined SCSI adapter Use a more recent version of diagnostics
420505 Ciss Device, Sequential Read Test Device reported problem Use a more recent version of diagnostics
420505 Ciss Device, Sequential Read Test Unknown device type Use a more recent version of diagnostics
420202 Ciss Device, Butterfly Read Test BMIC driver reported problem Check that Smart Array firmware and device drivers are up to date
420505 Ciss Device, Butterfly Read Test Cannot open filesystem table Use a more recent version of diagnostics
420303 Ciss Device, Butterfly Read Test CISS driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Ciss Device, Butterfly Read Test Driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Ciss Device, Butterfly Read Test Controller is not supported Check that Smart Array firmware and device drivers are up to date
420710 Ciss Device, Butterfly Read Test Error limit exceeded Replace disk drive or media
420505 Ciss Device, Butterfly Read Test No fibre channel port selected Use a more recent version of diagnostics
420505 Ciss Device, Butterfly Read Test Could not access file Use a more recent version of diagnostics
420505 Ciss Device, Butterfly Read Test Invalid access order Select a different access order for this test
420505 Ciss Device, Butterfly Read Test Invalid parameter list Select different parameters for this test
420710 Ciss Device, Butterfly Read Test Could not access media Replace disk drive or media
420202 Ciss Device, Butterfly Read Test Cannot determine bus speed Check that Smart Array firmware and device drivers are up to date
420202 Ciss Device, Butterfly Read Test Cannot determine bus width Check that Smart Array firmware and device drivers are up to date
420505 Ciss Device, Butterfly Read Test SCSI command is not supported Use a more recent version of diagnostics
420505 Ciss Device, Butterfly Read Test SCSI adapter not implemented Use a more recent version of diagnostics
420710 Ciss Device, Butterfly Read Test Could not transfer SCSI data Check SCSI cables and connectors
420505 Ciss Device, Butterfly Read Test SCSI device not implemented Use a more recent version of diagnostics
420505 Ciss Device, Butterfly Read Test Undefined SCSI adapter Use a more recent version of diagnostics
420505 Ciss Device, Butterfly Read Test Device reported problem Use a more recent version of diagnostics
420505 Ciss Device, Butterfly Read Test Unknown device type Use a more recent version of diagnostics
420202 Ciss Device, Random Read Test BMIC driver reported problem Check that Smart Array firmware and device drivers are up to date
420505 Ciss Device, Random Read Test Cannot open filesystem table Use a more recent version of diagnostics
420303 Ciss Device, Random Read Test CISS driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Ciss Device, Random Read Test Driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Ciss Device, Random Read Test Controller is not supported Check that Smart Array firmware and device drivers are up to date
420710 Ciss Device, Random Read Test Error limit exceeded Replace disk drive or media
420505 Ciss Device, Random Read Test No fibre channel port selected Use a more recent version of diagnostics
420505 Ciss Device, Random Read Test Could not access file Use a more recent version of diagnostics
420505 Ciss Device, Random Read Test Invalid access order Select a different access order for this test
420505 Ciss Device, Random Read Test Invalid parameter list Select different parameters for this test
420710 Ciss Device, Random Read Test Could not access media Replace disk drive or media
420202 Ciss Device, Random Read Test Cannot determine bus speed Check that Smart Array firmware and device drivers are up to date
420202 Ciss Device, Random Read Test Cannot determine bus width Check that Smart Array firmware and device drivers are up to date
420505 Ciss Device, Random Read Test SCSI command is not supported Use a more recent version of diagnostics
420505 Ciss Device, Random Read Test SCSI adapter not implemented Use a more recent version of diagnostics
420710 Ciss Device, Random Read Test Could not transfer SCSI data Check SCSI cables and connectors
420505 Ciss Device, Random Read Test SCSI device not implemented Use a more recent version of diagnostics
420505 Ciss Device, Random Read Test Undefined SCSI adapter Use a more recent version of diagnostics
420505 Ciss Device, Random Read Test Device reported problem Use a more recent version of diagnostics
420505 Ciss Device, Random Read Test Unknown device type Use a more recent version of diagnostics
420202 Ciss Device, Sequential Seek Test BMIC driver reported problem Check that Smart Array firmware and device drivers are up to date
420505 Ciss Device, Sequential Seek Test Cannot open filesystem table Use a more recent version of diagnostics
420303 Ciss Device, Sequential Seek Test CISS driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Ciss Device, Sequential Seek Test Driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Ciss Device, Sequential Seek Test Controller is not supported Check that Smart Array firmware and device drivers are up to date
420710 Ciss Device, Sequential Seek Test Error limit exceeded Replace disk drive or media
420505 Ciss Device, Sequential Seek Test No fibre channel port selected Use a more recent version of diagnostics
420505 Ciss Device, Sequential Seek Test Could not access file Use a more recent version of diagnostics
420505 Ciss Device, Sequential Seek Test Invalid access order Select a different access order for this test
420505 Ciss Device, Sequential Seek Test Invalid parameter list Select different parameters for this test
420710 Ciss Device, Sequential Seek Test Could not access media Replace disk drive or media
420202 Ciss Device, Sequential Seek Test Cannot determine bus speed Check that Smart Array firmware and device drivers are up to date
420202 Ciss Device, Sequential Seek Test Cannot determine bus width Check that Smart Array firmware and device drivers are up to date
420505 Ciss Device, Sequential Seek Test SCSI command is not supported Use a more recent version of diagnostics
420505 Ciss Device, Sequential Seek Test SCSI adapter not implemented Use a more recent version of diagnostics
420710 Ciss Device, Sequential Seek Test Could not transfer SCSI data Check SCSI cables and connectors
420505 Ciss Device, Sequential Seek Test SCSI device not implemented Use a more recent version of diagnostics
420505 Ciss Device, Sequential Seek Test Undefined SCSI adapter Use a more recent version of diagnostics
420505 Ciss Device, Sequential Seek Test Device reported problem Use a more recent version of diagnostics
420505 Ciss Device, Sequential Seek Test Unknown device type Use a more recent version of diagnostics
420202 Ciss Device, Butterfly Seek Test BMIC driver reported problem Check that Smart Array firmware and device drivers are up to date
420505 Ciss Device, Butterfly Seek Test Cannot open filesystem table Use a more recent version of diagnostics
420303 Ciss Device, Butterfly Seek Test CISS driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Ciss Device, Butterfly Seek Test Driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Ciss Device, Butterfly Seek Test Controller is not supported Check that Smart Array firmware and device drivers are up to date
420710 Ciss Device, Butterfly Seek Test Error limit exceeded Replace disk drive or media
420505 Ciss Device, Butterfly Seek Test No fibre channel port selected Use a more recent version of diagnostics
420505 Ciss Device, Butterfly Seek Test Could not access file Use a more recent version of diagnostics
420505 Ciss Device, Butterfly Seek Test Invalid access order Select a different access order for this test
420505 Ciss Device, Butterfly Seek Test Invalid parameter list Select different parameters for this test
420710 Ciss Device, Butterfly Seek Test Could not access media Replace disk drive or media
420202 Ciss Device, Butterfly Seek Test Cannot determine bus speed Check that Smart Array firmware and device drivers are up to date
420202 Ciss Device, Butterfly Seek Test Cannot determine bus width Check that Smart Array firmware and device drivers are up to date
420505 Ciss Device, Butterfly Seek Test SCSI command is not supported Use a more recent version of diagnostics
420505 Ciss Device, Butterfly Seek Test SCSI adapter not implemented Use a more recent version of diagnostics
420710 Ciss Device, Butterfly Seek Test Could not transfer SCSI data Check SCSI cables and connectors
420505 Ciss Device, Butterfly Seek Test SCSI device not implemented Use a more recent version of diagnostics
420505 Ciss Device, Butterfly Seek Test Undefined SCSI adapter Use a more recent version of diagnostics
420505 Ciss Device, Butterfly Seek Test Device reported problem Use a more recent version of diagnostics
420505 Ciss Device, Butterfly Seek Test Unknown device type Use a more recent version of diagnostics
420202 Ciss Device, Random Seek Test BMIC driver reported problem Check that Smart Array firmware and device drivers are up to date
420505 Ciss Device, Random Seek Test Cannot open filesystem table Use a more recent version of diagnostics
420303 Ciss Device, Random Seek Test CISS driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Ciss Device, Random Seek Test Driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Ciss Device, Random Seek Test Controller is not supported Check that Smart Array firmware and device drivers are up to date
420710 Ciss Device, Random Seek Test Error limit exceeded Replace disk drive or media
420505 Ciss Device, Random Seek Test No fibre channel port selected Use a more recent version of diagnostics
420505 Ciss Device, Random Seek Test Could not access file Use a more recent version of diagnostics
420505 Ciss Device, Random Seek Test Invalid access order Select a different access order for this test
420505 Ciss Device, Random Seek Test Invalid parameter list Select different parameters for this test
420710 Ciss Device, Random Seek Test Could not access media Replace disk drive or media
420202 Ciss Device, Random Seek Test Cannot determine bus speed Check that Smart Array firmware and device drivers are up to date
420202 Ciss Device, Random Seek Test Cannot determine bus width Check that Smart Array firmware and device drivers are up to date
420505 Ciss Device, Random Seek Test SCSI command is not supported Use a more recent version of diagnostics
420505 Ciss Device, Random Seek Test SCSI adapter not implemented Use a more recent version of diagnostics
420710 Ciss Device, Random Seek Test Could not transfer SCSI data Check SCSI cables and connectors
420505 Ciss Device, Random Seek Test SCSI device not implemented Use a more recent version of diagnostics
420505 Ciss Device, Random Seek Test Undefined SCSI adapter Use a more recent version of diagnostics
420505 Ciss Device, Random Seek Test Device reported problem Use a more recent version of diagnostics
420505 Ciss Device, Random Seek Test Unknown device type Use a more recent version of diagnostics
420202 Logical Volume, SCSI Self Test BMIC driver reported problem Check that Smart Array firmware and device drivers are up to date
420505 Logical Volume, SCSI Self Test Cannot open filesystem table Use a more recent version of diagnostics
420303 Logical Volume, SCSI Self Test CISS driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Logical Volume, SCSI Self Test Driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Logical Volume, SCSI Self Test Controller is not supported Check that Smart Array firmware and device drivers are up to date
420710 Logical Volume, SCSI Self Test Error limit exceeded Replace disk drive or media
420505 Logical Volume, SCSI Self Test No fibre channel port selected Use a more recent version of diagnostics
420505 Logical Volume, SCSI Self Test Could not access file Use a more recent version of diagnostics
420505 Logical Volume, SCSI Self Test Invalid access order Select a different access order for this test
420505 Logical Volume, SCSI Self Test Invalid parameter list Select different parameters for this test
420710 Logical Volume, SCSI Self Test Could not access media Replace disk drive or media
420202 Logical Volume, SCSI Self Test Cannot determine bus speed Check that Smart Array firmware and device drivers are up to date
420202 Logical Volume, SCSI Self Test Cannot determine bus width Check that Smart Array firmware and device drivers are up to date
420505 Logical Volume, SCSI Self Test SCSI command is not supported Use a more recent version of diagnostics
420505 Logical Volume, SCSI Self Test SCSI adapter not implemented Use a more recent version of diagnostics
420710 Logical Volume, SCSI Self Test Could not transfer SCSI data Check SCSI cables and connectors
420505 Logical Volume, SCSI Self Test SCSI device not implemented Use a more recent version of diagnostics
420505 Logical Volume, SCSI Self Test Undefined SCSI adapter Use a more recent version of diagnostics
420505 Logical Volume, SCSI Self Test Device reported problem Use a more recent version of diagnostics
420505 Logical Volume, SCSI Self Test Unknown device type Use a more recent version of diagnostics
420202 Logical Volume, Bus Speed Test BMIC driver reported problem Check that Smart Array firmware and device drivers are up to date
420505 Logical Volume, Bus Speed Test Cannot open filesystem table Use a more recent version of diagnostics
420303 Logical Volume, Bus Speed Test CISS driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Logical Volume, Bus Speed Test Driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Logical Volume, Bus Speed Test Controller is not supported Check that Smart Array firmware and device drivers are up to date
420710 Logical Volume, Bus Speed Test Error limit exceeded Replace disk drive or media
420505 Logical Volume, Bus Speed Test No fibre channel port selected Use a more recent version of diagnostics
420505 Logical Volume, Bus Speed Test Could not access file Use a more recent version of diagnostics
420505 Logical Volume, Bus Speed Test Invalid access order Select a different access order for this test
420505 Logical Volume, Bus Speed Test Invalid parameter list Select different parameters for this test
420710 Logical Volume, Bus Speed Test Could not access media Replace disk drive or media
420202 Logical Volume, Bus Speed Test Cannot determine bus speed Check that Smart Array firmware and device drivers are up to date
420202 Logical Volume, Bus Speed Test Cannot determine bus width Check that Smart Array firmware and device drivers are up to date
420505 Logical Volume, Bus Speed Test SCSI command is not supported Use a more recent version of diagnostics
420505 Logical Volume, Bus Speed Test SCSI adapter not implemented Use a more recent version of diagnostics
420710 Logical Volume, Bus Speed Test Could not transfer SCSI data Check SCSI cables and connectors
420505 Logical Volume, Bus Speed Test SCSI device not implemented Use a more recent version of diagnostics
420505 Logical Volume, Bus Speed Test Undefined SCSI adapter Use a more recent version of diagnostics
420505 Logical Volume, Bus Speed Test Device reported problem Use a more recent version of diagnostics
420505 Logical Volume, Bus Speed Test Unknown device type Use a more recent version of diagnostics
420202 Logical Volume, Sequential Verify Test BMIC driver reported problem Check that Smart Array firmware and device drivers are up to date
420505 Logical Volume, Sequential Verify Test Cannot open filesystem table Use a more recent version of diagnostics
420303 Logical Volume, Sequential Verify Test CISS driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Logical Volume, Sequential Verify Test Driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Logical Volume, Sequential Verify Test Controller is not supported Check that Smart Array firmware and device drivers are up to date
420710 Logical Volume, Sequential Verify Test Error limit exceeded Replace disk drive or media
420505 Logical Volume, Sequential Verify Test No fibre channel port selected Use a more recent version of diagnostics
420505 Logical Volume, Sequential Verify Test Could not access file Use a more recent version of diagnostics
420505 Logical Volume, Sequential Verify Test Invalid access order Select a different access order for this test
420505 Logical Volume, Sequential Verify Test Invalid parameter list Select different parameters for this test
420710 Logical Volume, Sequential Verify Test Could not access media Replace disk drive or media
420202 Logical Volume, Sequential Verify Test Cannot determine bus speed Check that Smart Array firmware and device drivers are up to date
420202 Logical Volume, Sequential Verify Test Cannot determine bus width Check that Smart Array firmware and device drivers are up to date
420505 Logical Volume, Sequential Verify Test SCSI command is not supported Use a more recent version of diagnostics
420505 Logical Volume, Sequential Verify Test SCSI adapter not implemented Use a more recent version of diagnostics
420710 Logical Volume, Sequential Verify Test Could not transfer SCSI data Check SCSI cables and connectors
420505 Logical Volume, Sequential Verify Test SCSI device not implemented Use a more recent version of diagnostics
420505 Logical Volume, Sequential Verify Test Undefined SCSI adapter Use a more recent version of diagnostics
420505 Logical Volume, Sequential Verify Test Device reported problem Use a more recent version of diagnostics
420505 Logical Volume, Sequential Verify Test Unknown device type Use a more recent version of diagnostics
420202 Logical Volume, Sequential Read Test BMIC driver reported problem Check that Smart Array firmware and device drivers are up to date
420505 Logical Volume, Sequential Read Test Cannot open filesystem table Use a more recent version of diagnostics
420303 Logical Volume, Sequential Read Test CISS driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Logical Volume, Sequential Read Test Driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Logical Volume, Sequential Read Test Controller is not supported Check that Smart Array firmware and device drivers are up to date
420710 Logical Volume, Sequential Read Test Error limit exceeded Replace disk drive or media
420505 Logical Volume, Sequential Read Test No fibre channel port selected Use a more recent version of diagnostics
420505 Logical Volume, Sequential Read Test Could not access file Use a more recent version of diagnostics
420505 Logical Volume, Sequential Read Test Invalid access order Select a different access order for this test
420505 Logical Volume, Sequential Read Test Invalid parameter list Select different parameters for this test
420710 Logical Volume, Sequential Read Test Could not access media Replace disk drive or media
420202 Logical Volume, Sequential Read Test Cannot determine bus speed Check that Smart Array firmware and device drivers are up to date
420202 Logical Volume, Sequential Read Test Cannot determine bus width Check that Smart Array firmware and device drivers are up to date
420505 Logical Volume, Sequential Read Test SCSI command is not supported Use a more recent version of diagnostics
420505 Logical Volume, Sequential Read Test SCSI adapter not implemented Use a more recent version of diagnostics
420710 Logical Volume, Sequential Read Test Could not transfer SCSI data Check SCSI cables and connectors
420505 Logical Volume, Sequential Read Test SCSI device not implemented Use a more recent version of diagnostics
420505 Logical Volume, Sequential Read Test Undefined SCSI adapter Use a more recent version of diagnostics
420505 Logical Volume, Sequential Read Test Device reported problem Use a more recent version of diagnostics
420505 Logical Volume, Sequential Read Test Unknown device type Use a more recent version of diagnostics
420202 Logical Volume, Butterfly Read Test BMIC driver reported problem Check that Smart Array firmware and device drivers are up to date
420505 Logical Volume, Butterfly Read Test Cannot open filesystem table Use a more recent version of diagnostics
420303 Logical Volume, Butterfly Read Test CISS driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Logical Volume, Butterfly Read Test Driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Logical Volume, Butterfly Read Test Controller is not supported Check that Smart Array firmware and device drivers are up to date
420710 Logical Volume, Butterfly Read Test Error limit exceeded Replace disk drive or media
420505 Logical Volume, Butterfly Read Test No fibre channel port selected Use a more recent version of diagnostics
420505 Logical Volume, Butterfly Read Test Could not access file Use a more recent version of diagnostics
420505 Logical Volume, Butterfly Read Test Invalid access order Select a different access order for this test
420505 Logical Volume, Butterfly Read Test Invalid parameter list Select different parameters for this test
420710 Logical Volume, Butterfly Read Test Could not access media Replace disk drive or media
420202 Logical Volume, Butterfly Read Test Cannot determine bus speed Check that Smart Array firmware and device drivers are up to date
420202 Logical Volume, Butterfly Read Test Cannot determine bus width Check that Smart Array firmware and device drivers are up to date
420505 Logical Volume, Butterfly Read Test SCSI command is not supported Use a more recent version of diagnostics
420505 Logical Volume, Butterfly Read Test SCSI adapter not implemented Use a more recent version of diagnostics
420710 Logical Volume, Butterfly Read Test Could not transfer SCSI data Check SCSI cables and connectors
420505 Logical Volume, Butterfly Read Test SCSI device not implemented Use a more recent version of diagnostics
420505 Logical Volume, Butterfly Read Test Undefined SCSI adapter Use a more recent version of diagnostics
420505 Logical Volume, Butterfly Read Test Device reported problem Use a more recent version of diagnostics
420505 Logical Volume, Butterfly Read Test Unknown device type Use a more recent version of diagnostics
420202 Logical Volume, Random Read Test BMIC driver reported problem Check that Smart Array firmware and device drivers are up to date
420505 Logical Volume, Random Read Test Cannot open filesystem table Use a more recent version of diagnostics
420303 Logical Volume, Random Read Test CISS driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Logical Volume, Random Read Test Driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Logical Volume, Random Read Test Controller is not supported Check that Smart Array firmware and device drivers are up to date
420710 Logical Volume, Random Read Test Error limit exceeded Replace disk drive or media
420505 Logical Volume, Random Read Test No fibre channel port selected Use a more recent version of diagnostics
420505 Logical Volume, Random Read Test Could not access file Use a more recent version of diagnostics
420505 Logical Volume, Random Read Test Invalid access order Select a different access order for this test
420505 Logical Volume, Random Read Test Invalid parameter list Select different parameters for this test
420710 Logical Volume, Random Read Test Could not access media Replace disk drive or media
420202 Logical Volume, Random Read Test Cannot determine bus speed Check that Smart Array firmware and device drivers are up to date
420202 Logical Volume, Random Read Test Cannot determine bus width Check that Smart Array firmware and device drivers are up to date
420505 Logical Volume, Random Read Test SCSI command is not supported Use a more recent version of diagnostics
420505 Logical Volume, Random Read Test SCSI adapter not implemented Use a more recent version of diagnostics
420710 Logical Volume, Random Read Test Could not transfer SCSI data Check SCSI cables and connectors
420505 Logical Volume, Random Read Test SCSI device not implemented Use a more recent version of diagnostics
420505 Logical Volume, Random Read Test Undefined SCSI adapter Use a more recent version of diagnostics
420505 Logical Volume, Random Read Test Device reported problem Use a more recent version of diagnostics
420505 Logical Volume, Random Read Test Unknown device type Use a more recent version of diagnostics
420202 Logical Volume, Sequential Seek Test BMIC driver reported problem Check that Smart Array firmware and device drivers are up to date
420505 Logical Volume, Sequential Seek Test Cannot open filesystem table Use a more recent version of diagnostics
420303 Logical Volume, Sequential Seek Test CISS driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Logical Volume, Sequential Seek Test Driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Logical Volume, Sequential Seek Test Controller is not supported Check that Smart Array firmware and device drivers are up to date
420710 Logical Volume, Sequential Seek Test Error limit exceeded Replace disk drive or media
420505 Logical Volume, Sequential Seek Test No fibre channel port selected Use a more recent version of diagnostics
420505 Logical Volume, Sequential Seek Test Could not access file Use a more recent version of diagnostics
420505 Logical Volume, Sequential Seek Test Invalid access order Select a different access order for this test
420505 Logical Volume, Sequential Seek Test Invalid parameter list Select different parameters for this test
420710 Logical Volume, Sequential Seek Test Could not access media Replace disk drive or media
420202 Logical Volume, Sequential Seek Test Cannot determine bus speed Check that Smart Array firmware and device drivers are up to date
420202 Logical Volume, Sequential Seek Test Cannot determine bus width Check that Smart Array firmware and device drivers are up to date
420505 Logical Volume, Sequential Seek Test SCSI command is not supported Use a more recent version of diagnostics
420505 Logical Volume, Sequential Seek Test SCSI adapter not implemented Use a more recent version of diagnostics
420710 Logical Volume, Sequential Seek Test Could not transfer SCSI data Check SCSI cables and connectors
420505 Logical Volume, Sequential Seek Test SCSI device not implemented Use a more recent version of diagnostics
420505 Logical Volume, Sequential Seek Test Undefined SCSI adapter Use a more recent version of diagnostics
420505 Logical Volume, Sequential Seek Test Device reported problem Use a more recent version of diagnostics
420505 Logical Volume, Sequential Seek Test Unknown device type Use a more recent version of diagnostics
420202 Logical Volume, Butterfly Seek Test BMIC driver reported problem Check that Smart Array firmware and device drivers are up to date
420505 Logical Volume, Butterfly Seek Test Cannot open filesystem table Use a more recent version of diagnostics
420303 Logical Volume, Butterfly Seek Test CISS driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Logical Volume, Butterfly Seek Test Driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Logical Volume, Butterfly Seek Test Controller is not supported Check that Smart Array firmware and device drivers are up to date
420710 Logical Volume, Butterfly Seek Test Error limit exceeded Replace disk drive or media
420505 Logical Volume, Butterfly Seek Test No fibre channel port selected Use a more recent version of diagnostics
420505 Logical Volume, Butterfly Seek Test Could not access file Use a more recent version of diagnostics
420505 Logical Volume, Butterfly Seek Test Invalid access order Select a different access order for this test
420505 Logical Volume, Butterfly Seek Test Invalid parameter list Select different parameters for this test
420710 Logical Volume, Butterfly Seek Test Could not access media Replace disk drive or media
420202 Logical Volume, Butterfly Seek Test Cannot determine bus speed Check that Smart Array firmware and device drivers are up to date
420202 Logical Volume, Butterfly Seek Test Cannot determine bus width Check that Smart Array firmware and device drivers are up to date
420505 Logical Volume, Butterfly Seek Test SCSI command is not supported Use a more recent version of diagnostics
420505 Logical Volume, Butterfly Seek Test SCSI adapter not implemented Use a more recent version of diagnostics
420710 Logical Volume, Butterfly Seek Test Could not transfer SCSI data Check SCSI cables and connectors
420505 Logical Volume, Butterfly Seek Test SCSI device not implemented Use a more recent version of diagnostics
420505 Logical Volume, Butterfly Seek Test Undefined SCSI adapter Use a more recent version of diagnostics
420505 Logical Volume, Butterfly Seek Test Device reported problem Use a more recent version of diagnostics
420505 Logical Volume, Butterfly Seek Test Unknown device type Use a more recent version of diagnostics
420202 Logical Volume, Random Seek Test BMIC driver reported problem Check that Smart Array firmware and device drivers are up to date
420505 Logical Volume, Random Seek Test Cannot open filesystem table Use a more recent version of diagnostics
420303 Logical Volume, Random Seek Test CISS driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Logical Volume, Random Seek Test Driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Logical Volume, Random Seek Test Controller is not supported Check that Smart Array firmware and device drivers are up to date
420710 Logical Volume, Random Seek Test Error limit exceeded Replace disk drive or media
420505 Logical Volume, Random Seek Test No fibre channel port selected Use a more recent version of diagnostics
420505 Logical Volume, Random Seek Test Could not access file Use a more recent version of diagnostics
420505 Logical Volume, Random Seek Test Invalid access order Select a different access order for this test
420505 Logical Volume, Random Seek Test Invalid parameter list Select different parameters for this test
420710 Logical Volume, Random Seek Test Could not access media Replace disk drive or media
420202 Logical Volume, Random Seek Test Cannot determine bus speed Check that Smart Array firmware and device drivers are up to date
420202 Logical Volume, Random Seek Test Cannot determine bus width Check that Smart Array firmware and device drivers are up to date
420505 Logical Volume, Random Seek Test SCSI command is not supported Use a more recent version of diagnostics
420505 Logical Volume, Random Seek Test SCSI adapter not implemented Use a more recent version of diagnostics
420710 Logical Volume, Random Seek Test Could not transfer SCSI data Check SCSI cables and connectors
420505 Logical Volume, Random Seek Test SCSI device not implemented Use a more recent version of diagnostics
420505 Logical Volume, Random Seek Test Undefined SCSI adapter Use a more recent version of diagnostics
420505 Logical Volume, Random Seek Test Device reported problem Use a more recent version of diagnostics
420505 Logical Volume, Random Seek Test Unknown device type Use a more recent version of diagnostics
420202 Raid Disk, SCSI Self Test BMIC driver reported problem Upgrade the controller driver and firmware. Verify you are using the latest version of the Insight Diagnostics software.
420505 Raid Disk, SCSI Self Test Cannot open filesystem table Reboot or restart Insight Diagnostics. Retry the test. If the problem persists, upgrade to the latest version of Insight Diagnostics.
420303 Raid Disk, SCSI Self Test CISS driver reported problem Upgrade the controller driver and firmware. Verify you are using the latest version of the Insight Diagnostics software.
420101 Raid Disk, SCSI Self Test Driver reported problem Upgrade the controller driver and firmware. Verify you are using the latest version of the Insight Diagnostics software.
420101 Raid Disk, SCSI Self Test Controller is not supported Upgrade to the latest controller driver and firmware. Verify you are using the latest version of the Insight Diagnostics software. If the problem persists, replace the controller.
420710 Raid Disk, SCSI Self Test Error limit exceeded Check the SCSI setup and configuration by confirming the SCSI IDs and checking that the SCSI bus is properly terminated. Inspect the SCSI cables and connectors for damage. Reseat drives and controllers. Try to isolate the error to a particular component in the SCSI subsystem by swapping with known, good devices. Remove non-HP devices when isolating the problem. Replace the failed component if the problem persists.
420505 Raid Disk, SCSI Self Test No fibre channel port selected Reboot or restart Insight Diagnostics. Retry the test. If the problem persists, upgrade to the latest version of Insight Diagnostics.
420505 Raid Disk, SCSI Self Test Could not access file Reboot or restart Insight Diagnostics. Retry the tests. If the problem persists, upgrade to the latest version of the Insight Diagnostics software. Check your operating system for available disk space. Insight Diagnostics requires some free disk space during normal operating procedures.
420505 Raid Disk, SCSI Self Test Invalid access order If the test was script-based, check and select valid test parameters. Retry the test. Verify you are using the latest version of Insight Diagnostics.
420505 Raid Disk, SCSI Self Test Invalid parameter list If the test was script-based, check and select valid test parameters. Retry the test. Verify you are using the latest version of Insight Diagnostics.
420710 Raid Disk, SCSI Self Test Could not access media Make sure proper known, good media is in the device. For tape devices, apply the head cleaner according to the user guide. Retest with new media. Replace the failed device if the error persists.
420202 Raid Disk, SCSI Self Test Cannot determine bus speed Upgrade the controller driver and firmware. Verify you are using the latest version of the Insight Diagnostics software. Check SCSI cables for damaged or bent pins. Check for proper bus termination.
420202 Raid Disk, SCSI Self Test Cannot determine bus width Upgrade the controller driver and firmware. Verify you are using the latest version of the Insight Diagnostics software. Check SCSI cables for damaged or bent pins. Check for proper bus termination.
420505 Raid Disk, SCSI Self Test SCSI command is not supported Reboot or restart Insight Diagnostics. Retry the test. If the problem persists, upgrade to the latest version of Insight Diagnostics.
420505 Raid Disk, SCSI Self Test SCSI adapter not implemented Reboot or restart Insight Diagnostics. Retry the test. If the problem persists, upgrade to the latest version of Insight Diagnostics.
420710 Raid Disk, SCSI Self Test Could not transfer SCSI data Check SCSI cables for damaged or bent pins. Check for proper bus termination.
420505 Raid Disk, SCSI Self Test SCSI device not implemented Reboot or restart Insight Diagnostics. Retry the test. If the problem persists, upgrade to the latest version of Insight Diagnostics.
420505 Raid Disk, SCSI Self Test Undefined SCSI adapter Upgrade the controller driver and firmware. Verify you are using the latest version of the Insight Diagnostics software. Check the SCSI setup and configuration by confirming the SCSI IDs and checking that the SCSI bus is properly terminated. Inspect the SCSI cables and connectors for damage. Reseat drives and controllers. Try to isolate the error to a particular component in the SCSI subsystem by swapping with known, good devices. Remove non-HP devices when isolating the problem. Replace the failed component if the problem persists.
420505 Raid Disk, SCSI Self Test Device reported problem Reboot or restart Insight Diagnostics. Retry the test. If the problem persists, upgrade to the latest version of Insight Diagnostics.
420505 Raid Disk, SCSI Self Test Unknown device type Upgrade the controller driver and firmware. Verify you are using the latest version of the Insight Diagnostics software. Check the SCSI setup and configuration by confirming the SCSI IDs and checking that the SCSI bus is properly terminated. Inspect the SCSI cables and connectors for damage. Reseat drives and controllers. Try to isolate the error to a particular component in the SCSI subsystem by swapping with known, good devices. Remove non-HP devices when isolating the problem. Replace the failed component if the problem persists.
420202 Raid Disk, Bus Speed Test BMIC driver reported problem Upgrade the controller driver and firmware. Verify you are using the latest version of the Insight Diagnostics software.
420505 Raid Disk, Bus Speed Test Cannot open filesystem table Reboot or restart Insight Diagnostics. Retry the test. If the problem persists, upgrade to the latest version of Insight Diagnostics.
420303 Raid Disk, Bus Speed Test CISS driver reported problem Upgrade the controller driver and firmware. Verify you are using the latest version of the Insight Diagnostics software.
420101 Raid Disk, Bus Speed Test Driver reported problem Upgrade the controller driver and firmware. Verify you are using the latest version of the Insight Diagnostics software.
420101 Raid Disk, Bus Speed Test Controller is not supported Upgrade to the latest controller driver and firmware. Verify you are using the latest version of the Insight Diagnostics software. If the problem persists, replace the controller.
420710 Raid Disk, Bus Speed Test Error limit exceeded Check the SCSI setup and configuration by confirming the SCSI IDs and checking that the SCSI bus is properly terminated. Inspect the SCSI cables and connectors for damage. Reseat drives and controllers. Try to isolate the error to a particular component in the SCSI subsystem by swapping with known, good devices. Remove non-HP devices when isolating the problem. Replace the failed component if the problem persists.
420505 Raid Disk, Bus Speed Test No fibre channel port selected Reboot or restart Insight Diagnostics. Retry the test. If the problem persists, upgrade to the latest version of Insight Diagnostics.
420505 Raid Disk, Bus Speed Test Could not access file Reboot or restart Insight Diagnostics. Retry the tests. If the problem persists, upgrade to the latest version of the Insight Diagnostics software. Check your operating system for available disk space. Insight Diagnostics requires some free disk space during normal operating procedures.
420505 Raid Disk, Bus Speed Test Invalid access order If the test was script-based, check and select valid test parameters. Retry the test. Verify you are using the latest version of Insight Diagnostics.
420505 Raid Disk, Bus Speed Test Invalid parameter list If the test was script-based, check and select valid test parameters. Retry the test. Verify you are using the latest version of Insight Diagnostics.
420710 Raid Disk, Bus Speed Test Could not access media Make sure proper known, good media is in the device. For tape devices, apply the head cleaner according to the user guide. Retest with new media. Replace the failed device if the error persists.
420202 Raid Disk, Bus Speed Test Cannot determine bus speed Upgrade the controller driver and firmware. Verify you are using the latest version of the Insight Diagnostics software. Check SCSI cables for damaged or bent pins. Check for proper bus termination.
420202 Raid Disk, Bus Speed Test Cannot determine bus width Upgrade the controller driver and firmware. Verify you are using the latest version of the Insight Diagnostics software. Check SCSI cables for damaged or bent pins. Check for proper bus termination.
420505 Raid Disk, Bus Speed Test SCSI command is not supported Reboot or restart Insight Diagnostics. Retry the test. If the problem persists, upgrade to the latest version of Insight Diagnostics.
420505 Raid Disk, Bus Speed Test SCSI adapter not implemented Reboot or restart Insight Diagnostics. Retry the test. If the problem persists, upgrade to the latest version of Insight Diagnostics.
420710 Raid Disk, Bus Speed Test Could not transfer SCSI data Check SCSI cables for damaged or bent pins. Check for proper bus termination.
420505 Raid Disk, Bus Speed Test SCSI device not implemented Reboot or restart Insight Diagnostics. Retry the test. If the problem persists, upgrade to the latest version of Insight Diagnostics.
420505 Raid Disk, Bus Speed Test Undefined SCSI adapter Upgrade the controller driver and firmware. Verify you are using the latest version of the Insight Diagnostics software. Check the SCSI setup and configuration by confirming the SCSI IDs and checking that the SCSI bus is properly terminated. Inspect the SCSI cables and connectors for damage. Reseat drives and controllers. Try to isolate the error to a particular component in the SCSI subsystem by swapping with known, good devices. Remove non-HP devices when isolating the problem. Replace the failed component if the problem persists.
420505 Raid Disk, Bus Speed Test Device reported problem Reboot or restart Insight Diagnostics. Retry the test. If the problem persists, upgrade to the latest version of Insight Diagnostics.
420505 Raid Disk, Bus Speed Test Unknown device type Upgrade the controller driver and firmware. Verify you are using the latest version of the Insight Diagnostics software. Check the SCSI setup and configuration by confirming the SCSI IDs and checking that the SCSI bus is properly terminated. Inspect the SCSI cables and connectors for damage. Reseat drives and controllers. Try to isolate the error to a particular component in the SCSI subsystem by swapping with known, good devices. Remove non-HP devices when isolating the problem. Replace the failed component if the problem persists.
420202 Raid Disk, Sequential Verify Test BMIC driver reported problem Upgrade the controller driver and firmware. Verify you are using the latest version of the Insight Diagnostics software.
420505 Raid Disk, Sequential Verify Test Cannot open filesystem table Reboot or restart Insight Diagnostics. Retry the test. If the problem persists, upgrade to the latest version of Insight Diagnostics.
420303 Raid Disk, Sequential Verify Test CISS driver reported problem Upgrade the controller driver and firmware. Verify you are using the latest version of the Insight Diagnostics software.
420101 Raid Disk, Sequential Verify Test Driver reported problem Upgrade the controller driver and firmware. Verify you are using the latest version of the Insight Diagnostics software.
420101 Raid Disk, Sequential Verify Test Controller is not supported Upgrade to the latest controller driver and firmware. Verify you are using the latest version of the Insight Diagnostics software. If the problem persists, replace the controller.
420710 Raid Disk, Sequential Verify Test Error limit exceeded Check the SCSI setup and configuration by confirming the SCSI IDs and checking that the SCSI bus is properly terminated. Inspect the SCSI cables and connectors for damage. Reseat drives and controllers. Try to isolate the error to a particular component in the SCSI subsystem by swapping with known, good devices. Remove non-HP devices when isolating the problem. Replace the failed component if the problem persists.
420505 Raid Disk, Sequential Verify Test No fibre channel port selected Reboot or restart Insight Diagnostics. Retry the test. If the problem persists, upgrade to the latest version of Insight Diagnostics.
420505 Raid Disk, Sequential Verify Test Could not access file Reboot or restart Insight Diagnostics. Retry the tests. If the problem persists, upgrade to the latest version of the Insight Diagnostics software. Check your operating system for available disk space. Insight Diagnostics requires some free disk space during normal operating procedures.
420505 Raid Disk, Sequential Verify Test Invalid access order If the test was script-based, check and select valid test parameters. Retry the test. Verify you are using the latest version of Insight Diagnostics.
420505 Raid Disk, Sequential Verify Test Invalid parameter list If the test was script-based, check and select valid test parameters. Retry the test. Verify you are using the latest version of Insight Diagnostics.
420710 Raid Disk, Sequential Verify Test Could not access media Make sure proper known, good media is in the device. For tape devices, apply the head cleaner according to the user guide. Retest with new media. Replace the failed device if the error persists.
420202 Raid Disk, Sequential Verify Test Cannot determine bus speed Upgrade the controller driver and firmware. Verify you are using the latest version of the Insight Diagnostics software. Check SCSI cables for damaged or bent pins. Check for proper bus termination.
420202 Raid Disk, Sequential Verify Test Cannot determine bus width Upgrade the controller driver and firmware. Verify you are using the latest version of the Insight Diagnostics software. Check SCSI cables for damaged or bent pins. Check for proper bus termination.
420505 Raid Disk, Sequential Verify Test SCSI command is not supported Reboot or restart Insight Diagnostics. Retry the test. If the problem persists, upgrade to the latest version of Insight Diagnostics.
420505 Raid Disk, Sequential Verify Test SCSI adapter not implemented Reboot or restart Insight Diagnostics. Retry the test. If the problem persists, upgrade to the latest version of Insight Diagnostics.
420710 Raid Disk, Sequential Verify Test Could not transfer SCSI data Check SCSI cables for damaged or bent pins. Check for proper bus termination.
420505 Raid Disk, Sequential Verify Test SCSI device not implemented Reboot or restart Insight Diagnostics. Retry the test. If the problem persists, upgrade to the latest version of Insight Diagnostics.
420505 Raid Disk, Sequential Verify Test Undefined SCSI adapter Upgrade the controller driver and firmware. Verify you are using the latest version of the Insight Diagnostics software. Check the SCSI setup and configuration by confirming the SCSI IDs and checking that the SCSI bus is properly terminated. Inspect the SCSI cables and connectors for damage. Reseat drives and controllers. Try to isolate the error to a particular component in the SCSI subsystem by swapping with known, good devices. Remove non-HP devices when isolating the problem. Replace the failed component if the problem persists.
420505 Raid Disk, Sequential Verify Test Device reported problem Reboot or restart Insight Diagnostics. Retry the test. If the problem persists, upgrade to the latest version of Insight Diagnostics.
420505 Raid Disk, Sequential Verify Test Unknown device type Upgrade the controller driver and firmware. Verify you are using the latest version of the Insight Diagnostics software. Check the SCSI setup and configuration by confirming the SCSI IDs and checking that the SCSI bus is properly terminated. Inspect the SCSI cables and connectors for damage. Reseat drives and controllers. Try to isolate the error to a particular component in the SCSI subsystem by swapping with known, good devices. Remove non-HP devices when isolating the problem. Replace the failed component if the problem persists.
420202 Raid Disk, Sequential Read Test BMIC driver reported problem Upgrade the controller driver and firmware. Verify you are using the latest version of the Insight Diagnostics software.
420505 Raid Disk, Sequential Read Test Cannot open filesystem table Reboot or restart Insight Diagnostics. Retry the test. If the problem persists, upgrade to the latest version of Insight Diagnostics.
420303 Raid Disk, Sequential Read Test CISS driver reported problem Upgrade the controller driver and firmware. Verify you are using the latest version of the Insight Diagnostics software.
420101 Raid Disk, Sequential Read Test Driver reported problem Upgrade the controller driver and firmware. Verify you are using the latest version of the Insight Diagnostics software.
420101 Raid Disk, Sequential Read Test Controller is not supported Upgrade to the latest controller driver and firmware. Verify you are using the latest version of the Insight Diagnostics software. If the problem persists, replace the controller.
420710 Raid Disk, Sequential Read Test Error limit exceeded Check the SCSI setup and configuration by confirming the SCSI IDs and checking that the SCSI bus is properly terminated. Inspect the SCSI cables and connectors for damage. Reseat drives and controllers. Try to isolate the error to a particular component in the SCSI subsystem by swapping with known, good devices. Remove non-HP devices when isolating the problem. Replace the failed component if the problem persists.
420505 Raid Disk, Sequential Read Test No fibre channel port selected Reboot or restart Insight Diagnostics. Retry the test. If the problem persists, upgrade to the latest version of Insight Diagnostics.
420505 Raid Disk, Sequential Read Test Could not access file Reboot or restart Insight Diagnostics. Retry the tests. If the problem persists, upgrade to the latest version of the Insight Diagnostics software. Check your operating system for available disk space. Insight Diagnostics requires some free disk space during normal operating procedures.
420505 Raid Disk, Sequential Read Test Invalid access order If the test was script-based, check and select valid test parameters. Retry the test. Verify you are using the latest version of Insight Diagnostics.
420505 Raid Disk, Sequential Read Test Invalid parameter list If the test was script-based, check and select valid test parameters. Retry the test. Verify you are using the latest version of Insight Diagnostics.
420710 Raid Disk, Sequential Read Test Could not access media Make sure proper known, good media is in the device. For tape devices, apply the head cleaner according to the user guide. Retest with new media. Replace the failed device if the error persists.
420202 Raid Disk, Sequential Read Test Cannot determine bus speed Upgrade the controller driver and firmware. Verify you are using the latest version of the Insight Diagnostics software. Check SCSI cables for damaged or bent pins. Check for proper bus termination.
420202 Raid Disk, Sequential Read Test Cannot determine bus width Upgrade the controller driver and firmware. Verify you are using the latest version of the Insight Diagnostics software. Check SCSI cables for damaged or bent pins. Check for proper bus termination.
420505 Raid Disk, Sequential Read Test SCSI command is not supported Reboot or restart Insight Diagnostics. Retry the test. If the problem persists, upgrade to the latest version of Insight Diagnostics.
420505 Raid Disk, Sequential Read Test SCSI adapter not implemented Reboot or restart Insight Diagnostics. Retry the test. If the problem persists, upgrade to the latest version of Insight Diagnostics.
420710 Raid Disk, Sequential Read Test Could not transfer SCSI data Check SCSI cables for damaged or bent pins. Check for proper bus termination.
420505 Raid Disk, Sequential Read Test SCSI device not implemented Reboot or restart Insight Diagnostics. Retry the test. If the problem persists, upgrade to the latest version of Insight Diagnostics.
420505 Raid Disk, Sequential Read Test Undefined SCSI adapter Upgrade the controller driver and firmware. Verify you are using the latest version of the Insight Diagnostics software. Check the SCSI setup and configuration by confirming the SCSI IDs and checking that the SCSI bus is properly terminated. Inspect the SCSI cables and connectors for damage. Reseat drives and controllers. Try to isolate the error to a particular component in the SCSI subsystem by swapping with known, good devices. Remove non-HP devices when isolating the problem. Replace the failed component if the problem persists.
420505 Raid Disk, Sequential Read Test Device reported problem Reboot or restart Insight Diagnostics. Retry the test. If the problem persists, upgrade to the latest version of Insight Diagnostics.
420505 Raid Disk, Sequential Read Test Unknown device type Upgrade the controller driver and firmware. Verify you are using the latest version of the Insight Diagnostics software. Check the SCSI setup and configuration by confirming the SCSI IDs and checking that the SCSI bus is properly terminated. Inspect the SCSI cables and connectors for damage. Reseat drives and controllers. Try to isolate the error to a particular component in the SCSI subsystem by swapping with known, good devices. Remove non-HP devices when isolating the problem. Replace the failed component if the problem persists.
420202 Raid Disk, Butterfly Read Test BMIC driver reported problem Upgrade the controller driver and firmware. Verify you are using the latest version of the Insight Diagnostics software.
420505 Raid Disk, Butterfly Read Test Cannot open filesystem table Reboot or restart Insight Diagnostics. Retry the test. If the problem persists, upgrade to the latest version of Insight Diagnostics.
420303 Raid Disk, Butterfly Read Test CISS driver reported problem Upgrade the controller driver and firmware. Verify you are using the latest version of the Insight Diagnostics software.
420101 Raid Disk, Butterfly Read Test Driver reported problem Upgrade the controller driver and firmware. Verify you are using the latest version of the Insight Diagnostics software.
420101 Raid Disk, Butterfly Read Test Controller is not supported Upgrade to the latest controller driver and firmware. Verify you are using the latest version of the Insight Diagnostics software. If the problem persists, replace the controller.
420710 Raid Disk, Butterfly Read Test Error limit exceeded Check the SCSI setup and configuration by confirming the SCSI IDs and checking that the SCSI bus is properly terminated. Inspect the SCSI cables and connectors for damage. Reseat drives and controllers. Try to isolate the error to a particular component in the SCSI subsystem by swapping with known, good devices. Remove non-HP devices when isolating the problem. Replace the failed component if the problem persists.
420505 Raid Disk, Butterfly Read Test No fibre channel port selected Reboot or restart Insight Diagnostics. Retry the test. If the problem persists, upgrade to the latest version of Insight Diagnostics.
420505 Raid Disk, Butterfly Read Test Could not access file Reboot or restart Insight Diagnostics. Retry the tests. If the problem persists, upgrade to the latest version of the Insight Diagnostics software. Check your operating system for available disk space. Insight Diagnostics requires some free disk space during normal operating procedures.
420505 Raid Disk, Butterfly Read Test Invalid access order If the test was script-based, check and select valid test parameters. Retry the test. Verify you are using the latest version of Insight Diagnostics.
420505 Raid Disk, Butterfly Read Test Invalid parameter list If the test was script-based, check and select valid test parameters. Retry the test. Verify you are using the latest version of Insight Diagnostics.
420710 Raid Disk, Butterfly Read Test Could not access media Make sure proper known, good media is in the device. For tape devices, apply the head cleaner according to the user guide. Retest with new media. Replace the failed device if the error persists.
420202 Raid Disk, Butterfly Read Test Cannot determine bus speed Upgrade the controller driver and firmware. Verify you are using the latest version of the Insight Diagnostics software. Check SCSI cables for damaged or bent pins. Check for proper bus termination.
420202 Raid Disk, Butterfly Read Test Cannot determine bus width Upgrade the controller driver and firmware. Verify you are using the latest version of the Insight Diagnostics software. Check SCSI cables for damaged or bent pins. Check for proper bus termination.
420505 Raid Disk, Butterfly Read Test SCSI command is not supported Reboot or restart Insight Diagnostics. Retry the test. If the problem persists, upgrade to the latest version of Insight Diagnostics.
420505 Raid Disk, Butterfly Read Test SCSI adapter not implemented Reboot or restart Insight Diagnostics. Retry the test. If the problem persists, upgrade to the latest version of Insight Diagnostics.
420710 Raid Disk, Butterfly Read Test Could not transfer SCSI data Check SCSI cables for damaged or bent pins. Check for proper bus termination.
420505 Raid Disk, Butterfly Read Test SCSI device not implemented Reboot or restart Insight Diagnostics. Retry the test. If the problem persists, upgrade to the latest version of Insight Diagnostics.
420505 Raid Disk, Butterfly Read Test Undefined SCSI adapter Upgrade the controller driver and firmware. Verify you are using the latest version of the Insight Diagnostics software. Check the SCSI setup and configuration by confirming the SCSI IDs and checking that the SCSI bus is properly terminated. Inspect the SCSI cables and connectors for damage. Reseat drives and controllers. Try to isolate the error to a particular component in the SCSI subsystem by swapping with known, good devices. Remove non-HP devices when isolating the problem. Replace the failed component if the problem persists.
420505 Raid Disk, Butterfly Read Test Device reported problem Reboot or restart Insight Diagnostics. Retry the test. If the problem persists, upgrade to the latest version of Insight Diagnostics.
420505 Raid Disk, Butterfly Read Test Unknown device type Upgrade the controller driver and firmware. Verify you are using the latest version of the Insight Diagnostics software. Check the SCSI setup and configuration by confirming the SCSI IDs and checking that the SCSI bus is properly terminated. Inspect the SCSI cables and connectors for damage. Reseat drives and controllers. Try to isolate the error to a particular component in the SCSI subsystem by swapping with known, good devices. Remove non-HP devices when isolating the problem. Replace the failed component if the problem persists.
420202 Raid Disk, Random Read Test BMIC driver reported problem Upgrade the controller driver and firmware. Verify you are using the latest version of the Insight Diagnostics software.
420505 Raid Disk, Random Read Test Cannot open filesystem table Reboot or restart Insight Diagnostics. Retry the test. If the problem persists, upgrade to the latest version of Insight Diagnostics.
420303 Raid Disk, Random Read Test CISS driver reported problem Upgrade the controller driver and firmware. Verify you are using the latest version of the Insight Diagnostics software.
420101 Raid Disk, Random Read Test Driver reported problem Upgrade the controller driver and firmware. Verify you are using the latest version of the Insight Diagnostics software.
420101 Raid Disk, Random Read Test Controller is not supported Upgrade to the latest controller driver and firmware. Verify you are using the latest version of the Insight Diagnostics software. If the problem persists, replace the controller.
420710 Raid Disk, Random Read Test Error limit exceeded Check the SCSI setup and configuration by confirming the SCSI IDs and checking that the SCSI bus is properly terminated. Inspect the SCSI cables and connectors for damage. Reseat drives and controllers. Try to isolate the error to a particular component in the SCSI subsystem by swapping with known, good devices. Remove non-HP devices when isolating the problem. Replace the failed component if the problem persists.
420505 Raid Disk, Random Read Test No fibre channel port selected Reboot or restart Insight Diagnostics. Retry the test. If the problem persists, upgrade to the latest version of Insight Diagnostics.
420505 Raid Disk, Random Read Test Could not access file Reboot or restart Insight Diagnostics. Retry the tests. If the problem persists, upgrade to the latest version of the Insight Diagnostics software. Check your operating system for available disk space. Insight Diagnostics requires some free disk space during normal operating procedures.
420505 Raid Disk, Random Read Test Invalid access order If the test was script-based, check and select valid test parameters. Retry the test. Verify you are using the latest version of Insight Diagnostics.
420505 Raid Disk, Random Read Test Invalid parameter list If the test was script-based, check and select valid test parameters. Retry the test. Verify you are using the latest version of Insight Diagnostics.
420710 Raid Disk, Random Read Test Could not access media Make sure proper known, good media is in the device. For tape devices, apply the head cleaner according to the user guide. Retest with new media. Replace the failed device if the error persists.
420202 Raid Disk, Random Read Test Cannot determine bus speed Upgrade the controller driver and firmware. Verify you are using the latest version of the Insight Diagnostics software. Check SCSI cables for damaged or bent pins. Check for proper bus termination.
420202 Raid Disk, Random Read Test Cannot determine bus width Upgrade the controller driver and firmware. Verify you are using the latest version of the Insight Diagnostics software. Check SCSI cables for damaged or bent pins. Check for proper bus termination.
420505 Raid Disk, Random Read Test SCSI command is not supported Reboot or restart Insight Diagnostics. Retry the test. If the problem persists, upgrade to the latest version of Insight Diagnostics.
420505 Raid Disk, Random Read Test SCSI adapter not implemented Reboot or restart Insight Diagnostics. Retry the test. If the problem persists, upgrade to the latest version of Insight Diagnostics.
420710 Raid Disk, Random Read Test Could not transfer SCSI data Check SCSI cables for damaged or bent pins. Check for proper bus termination.
420505 Raid Disk, Random Read Test SCSI device not implemented Reboot or restart Insight Diagnostics. Retry the test. If the problem persists, upgrade to the latest version of Insight Diagnostics.
420505 Raid Disk, Random Read Test Undefined SCSI adapter Upgrade the controller driver and firmware. Verify you are using the latest version of the Insight Diagnostics software. Check the SCSI setup and configuration by confirming the SCSI IDs and checking that the SCSI bus is properly terminated. Inspect the SCSI cables and connectors for damage. Reseat drives and controllers. Try to isolate the error to a particular component in the SCSI subsystem by swapping with known, good devices. Remove non-HP devices when isolating the problem. Replace the failed component if the problem persists.
420505 Raid Disk, Random Read Test Device reported problem Reboot or restart Insight Diagnostics. Retry the test. If the problem persists, upgrade to the latest version of Insight Diagnostics.
420505 Raid Disk, Random Read Test Unknown device type Upgrade the controller driver and firmware. Verify you are using the latest version of the Insight Diagnostics software. Check the SCSI setup and configuration by confirming the SCSI IDs and checking that the SCSI bus is properly terminated. Inspect the SCSI cables and connectors for damage. Reseat drives and controllers. Try to isolate the error to a particular component in the SCSI subsystem by swapping with known, good devices. Remove non-HP devices when isolating the problem. Replace the failed component if the problem persists.
420202 Raid Disk, Sequential Seek Test BMIC driver reported problem Upgrade the controller driver and firmware. Verify you are using the latest version of the Insight Diagnostics software.
420505 Raid Disk, Sequential Seek Test Cannot open filesystem table Reboot or restart Insight Diagnostics. Retry the test. If the problem persists, upgrade to the latest version of Insight Diagnostics.
420303 Raid Disk, Sequential Seek Test CISS driver reported problem Upgrade the controller driver and firmware. Verify you are using the latest version of the Insight Diagnostics software.
420101 Raid Disk, Sequential Seek Test Driver reported problem Upgrade the controller driver and firmware. Verify you are using the latest version of the Insight Diagnostics software.
420101 Raid Disk, Sequential Seek Test Controller is not supported Upgrade to the latest controller driver and firmware. Verify you are using the latest version of the Insight Diagnostics software. If the problem persists, replace the controller.
420710 Raid Disk, Sequential Seek Test Error limit exceeded Check the SCSI setup and configuration by confirming the SCSI IDs and checking that the SCSI bus is properly terminated. Inspect the SCSI cables and connectors for damage. Reseat drives and controllers. Try to isolate the error to a particular component in the SCSI subsystem by swapping with known, good devices. Remove non-HP devices when isolating the problem. Replace the failed component if the problem persists.
420505 Raid Disk, Sequential Seek Test No fibre channel port selected Reboot or restart Insight Diagnostics. Retry the test. If the problem persists, upgrade to the latest version of Insight Diagnostics.
420505 Raid Disk, Sequential Seek Test Could not access file Reboot or restart Insight Diagnostics. Retry the tests. If the problem persists, upgrade to the latest version of the Insight Diagnostics software. Check your operating system for available disk space. Insight Diagnostics requires some free disk space during normal operating procedures.
420505 Raid Disk, Sequential Seek Test Invalid access order If the test was script-based, check and select valid test parameters. Retry the test. Verify you are using the latest version of Insight Diagnostics.
420505 Raid Disk, Sequential Seek Test Invalid parameter list If the test was script-based, check and select valid test parameters. Retry the test. Verify you are using the latest version of Insight Diagnostics.
420710 Raid Disk, Sequential Seek Test Could not access media Make sure proper known, good media is in the device. For tape devices, apply the head cleaner according to the user guide. Retest with new media. Replace the failed device if the error persists.
420202 Raid Disk, Sequential Seek Test Cannot determine bus speed Upgrade the controller driver and firmware. Verify you are using the latest version of the Insight Diagnostics software. Check SCSI cables for damaged or bent pins. Check for proper bus termination.
420202 Raid Disk, Sequential Seek Test Cannot determine bus width Upgrade the controller driver and firmware. Verify you are using the latest version of the Insight Diagnostics software. Check SCSI cables for damaged or bent pins. Check for proper bus termination.
420505 Raid Disk, Sequential Seek Test SCSI command is not supported Reboot or restart Insight Diagnostics. Retry the test. If the problem persists, upgrade to the latest version of Insight Diagnostics.
420505 Raid Disk, Sequential Seek Test SCSI adapter not implemented Reboot or restart Insight Diagnostics. Retry the test. If the problem persists, upgrade to the latest version of Insight Diagnostics.
420710 Raid Disk, Sequential Seek Test Could not transfer SCSI data Check SCSI cables for damaged or bent pins. Check for proper bus termination.
420505 Raid Disk, Sequential Seek Test SCSI device not implemented Reboot or restart Insight Diagnostics. Retry the test. If the problem persists, upgrade to the latest version of Insight Diagnostics.
420505 Raid Disk, Sequential Seek Test Undefined SCSI adapter Upgrade the controller driver and firmware. Verify you are using the latest version of the Insight Diagnostics software. Check the SCSI setup and configuration by confirming the SCSI IDs and checking that the SCSI bus is properly terminated. Inspect the SCSI cables and connectors for damage. Reseat drives and controllers. Try to isolate the error to a particular component in the SCSI subsystem by swapping with known, good devices. Remove non-HP devices when isolating the problem. Replace the failed component if the problem persists.
420505 Raid Disk, Sequential Seek Test Device reported problem Reboot or restart Insight Diagnostics. Retry the test. If the problem persists, upgrade to the latest version of Insight Diagnostics.
420505 Raid Disk, Sequential Seek Test Unknown device type Upgrade the controller driver and firmware. Verify you are using the latest version of the Insight Diagnostics software. Check the SCSI setup and configuration by confirming the SCSI IDs and checking that the SCSI bus is properly terminated. Inspect the SCSI cables and connectors for damage. Reseat drives and controllers. Try to isolate the error to a particular component in the SCSI subsystem by swapping with known, good devices. Remove non-HP devices when isolating the problem. Replace the failed component if the problem persists.
420202 Raid Disk, Butterfly Seek Test BMIC driver reported problem Upgrade the controller driver and firmware. Verify you are using the latest version of the Insight Diagnostics software.
420505 Raid Disk, Butterfly Seek Test Cannot open filesystem table Reboot or restart Insight Diagnostics. Retry the test. If the problem persists, upgrade to the latest version of Insight Diagnostics.
420303 Raid Disk, Butterfly Seek Test CISS driver reported problem Upgrade the controller driver and firmware. Verify you are using the latest version of the Insight Diagnostics software.
420101 Raid Disk, Butterfly Seek Test Driver reported problem Upgrade the controller driver and firmware. Verify you are using the latest version of the Insight Diagnostics software.
420101 Raid Disk, Butterfly Seek Test Controller is not supported Upgrade to the latest controller driver and firmware. Verify you are using the latest version of the Insight Diagnostics software. If the problem persists, replace the controller.
420710 Raid Disk, Butterfly Seek Test Error limit exceeded Check the SCSI setup and configuration by confirming the SCSI IDs and checking that the SCSI bus is properly terminated. Inspect the SCSI cables and connectors for damage. Reseat drives and controllers. Try to isolate the error to a particular component in the SCSI subsystem by swapping with known, good devices. Remove non-HP devices when isolating the problem. Replace the failed component if the problem persists.
420505 Raid Disk, Butterfly Seek Test No fibre channel port selected Reboot or restart Insight Diagnostics. Retry the test. If the problem persists, upgrade to the latest version of Insight Diagnostics.
420505 Raid Disk, Butterfly Seek Test Could not access file Reboot or restart Insight Diagnostics. Retry the tests. If the problem persists, upgrade to the latest version of the Insight Diagnostics software. Check your operating system for available disk space. Insight Diagnostics requires some free disk space during normal operating procedures.
420505 Raid Disk, Butterfly Seek Test Invalid access order If the test was script-based, check and select valid test parameters. Retry the test. Verify you are using the latest version of Insight Diagnostics.
420505 Raid Disk, Butterfly Seek Test Invalid parameter list If the test was script-based, check and select valid test parameters. Retry the test. Verify you are using the latest version of Insight Diagnostics.
420710 Raid Disk, Butterfly Seek Test Could not access media Make sure proper known, good media is in the device. For tape devices, apply the head cleaner according to the user guide. Retest with new media. Replace the failed device if the error persists.
420202 Raid Disk, Butterfly Seek Test Cannot determine bus speed Upgrade the controller driver and firmware. Verify you are using the latest version of the Insight Diagnostics software. Check SCSI cables for damaged or bent pins. Check for proper bus termination.
420202 Raid Disk, Butterfly Seek Test Cannot determine bus width Upgrade the controller driver and firmware. Verify you are using the latest version of the Insight Diagnostics software. Check SCSI cables for damaged or bent pins. Check for proper bus termination.
420505 Raid Disk, Butterfly Seek Test SCSI command is not supported Reboot or restart Insight Diagnostics. Retry the test. If the problem persists, upgrade to the latest version of Insight Diagnostics.
420505 Raid Disk, Butterfly Seek Test SCSI adapter not implemented Reboot or restart Insight Diagnostics. Retry the test. If the problem persists, upgrade to the latest version of Insight Diagnostics.
420710 Raid Disk, Butterfly Seek Test Could not transfer SCSI data Check SCSI cables for damaged or bent pins. Check for proper bus termination.
420505 Raid Disk, Butterfly Seek Test SCSI device not implemented Reboot or restart Insight Diagnostics. Retry the test. If the problem persists, upgrade to the latest version of Insight Diagnostics.
420505 Raid Disk, Butterfly Seek Test Undefined SCSI adapter Upgrade the controller driver and firmware. Verify you are using the latest version of the Insight Diagnostics software. Check the SCSI setup and configuration by confirming the SCSI IDs and checking that the SCSI bus is properly terminated. Inspect the SCSI cables and connectors for damage. Reseat drives and controllers. Try to isolate the error to a particular component in the SCSI subsystem by swapping with known, good devices. Remove non-HP devices when isolating the problem. Replace the failed component if the problem persists.
420505 Raid Disk, Butterfly Seek Test Device reported problem Reboot or restart Insight Diagnostics. Retry the test. If the problem persists, upgrade to the latest version of Insight Diagnostics.
420505 Raid Disk, Butterfly Seek Test Unknown device type Upgrade the controller driver and firmware. Verify you are using the latest version of the Insight Diagnostics software. Check the SCSI setup and configuration by confirming the SCSI IDs and checking that the SCSI bus is properly terminated. Inspect the SCSI cables and connectors for damage. Reseat drives and controllers. Try to isolate the error to a particular component in the SCSI subsystem by swapping with known, good devices. Remove non-HP devices when isolating the problem. Replace the failed component if the problem persists.
420202 Raid Disk, Random Seek Test BMIC driver reported problem Upgrade the controller driver and firmware. Verify you are using the latest version of the Insight Diagnostics software.
420505 Raid Disk, Random Seek Test Cannot open filesystem table Reboot or restart Insight Diagnostics. Retry the test. If the problem persists, upgrade to the latest version of Insight Diagnostics.
420303 Raid Disk, Random Seek Test CISS driver reported problem Upgrade the controller driver and firmware. Verify you are using the latest version of the Insight Diagnostics software.
420101 Raid Disk, Random Seek Test Driver reported problem Upgrade the controller driver and firmware. Verify you are using the latest version of the Insight Diagnostics software.
420101 Raid Disk, Random Seek Test Controller is not supported Upgrade to the latest controller driver and firmware. Verify you are using the latest version of the Insight Diagnostics software. If the problem persists, replace the controller.
420710 Raid Disk, Random Seek Test Error limit exceeded Check the SCSI setup and configuration by confirming the SCSI IDs and checking that the SCSI bus is properly terminated. Inspect the SCSI cables and connectors for damage. Reseat drives and controllers. Try to isolate the error to a particular component in the SCSI subsystem by swapping with known, good devices. Remove non-HP devices when isolating the problem. Replace the failed component if the problem persists.
420505 Raid Disk, Random Seek Test No fibre channel port selected Reboot or restart Insight Diagnostics. Retry the test. If the problem persists, upgrade to the latest version of Insight Diagnostics.
420505 Raid Disk, Random Seek Test Could not access file Reboot or restart Insight Diagnostics. Retry the tests. If the problem persists, upgrade to the latest version of the Insight Diagnostics software. Check your operating system for available disk space. Insight Diagnostics requires some free disk space during normal operating procedures.
420505 Raid Disk, Random Seek Test Invalid access order If the test was script-based, check and select valid test parameters. Retry the test. Verify you are using the latest version of Insight Diagnostics.
420505 Raid Disk, Random Seek Test Invalid parameter list If the test was script-based, check and select valid test parameters. Retry the test. Verify you are using the latest version of Insight Diagnostics.
420710 Raid Disk, Random Seek Test Could not access media Make sure proper known, good media is in the device. For tape devices, apply the head cleaner according to the user guide. Retest with new media. Replace the failed device if the error persists.
420202 Raid Disk, Random Seek Test Cannot determine bus speed Upgrade the controller driver and firmware. Verify you are using the latest version of the Insight Diagnostics software. Check SCSI cables for damaged or bent pins. Check for proper bus termination.
420202 Raid Disk, Random Seek Test Cannot determine bus width Upgrade the controller driver and firmware. Verify you are using the latest version of the Insight Diagnostics software. Check SCSI cables for damaged or bent pins. Check for proper bus termination.
420505 Raid Disk, Random Seek Test SCSI command is not supported Reboot or restart Insight Diagnostics. Retry the test. If the problem persists, upgrade to the latest version of Insight Diagnostics.
420505 Raid Disk, Random Seek Test SCSI adapter not implemented Reboot or restart Insight Diagnostics. Retry the test. If the problem persists, upgrade to the latest version of Insight Diagnostics.
420710 Raid Disk, Random Seek Test Could not transfer SCSI data Check SCSI cables for damaged or bent pins. Check for proper bus termination.
420505 Raid Disk, Random Seek Test SCSI device not implemented Reboot or restart Insight Diagnostics. Retry the test. If the problem persists, upgrade to the latest version of Insight Diagnostics.
420505 Raid Disk, Random Seek Test Undefined SCSI adapter Upgrade the controller driver and firmware. Verify you are using the latest version of the Insight Diagnostics software. Check the SCSI setup and configuration by confirming the SCSI IDs and checking that the SCSI bus is properly terminated. Inspect the SCSI cables and connectors for damage. Reseat drives and controllers. Try to isolate the error to a particular component in the SCSI subsystem by swapping with known, good devices. Remove non-HP devices when isolating the problem. Replace the failed component if the problem persists.
420505 Raid Disk, Random Seek Test Device reported problem Reboot or restart Insight Diagnostics. Retry the test. If the problem persists, upgrade to the latest version of Insight Diagnostics.
420505 Raid Disk, Random Seek Test Unknown device type Upgrade the controller driver and firmware. Verify you are using the latest version of the Insight Diagnostics software. Check the SCSI setup and configuration by confirming the SCSI IDs and checking that the SCSI bus is properly terminated. Inspect the SCSI cables and connectors for damage. Reseat drives and controllers. Try to isolate the error to a particular component in the SCSI subsystem by swapping with known, good devices. Remove non-HP devices when isolating the problem. Replace the failed component if the problem persists.
420202 SCSI Tape, SCSI Self Test BMIC driver reported problem Check that Smart Array firmware and device drivers are up to date
420505 SCSI Tape, SCSI Self Test Cannot open filesystem table Use a more recent version of diagnostics
420303 SCSI Tape, SCSI Self Test CISS driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 SCSI Tape, SCSI Self Test Driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 SCSI Tape, SCSI Self Test Controller is not supported Check that Smart Array firmware and device drivers are up to date
420710 SCSI Tape, SCSI Self Test Error limit exceeded Replace disk drive or media
420505 SCSI Tape, SCSI Self Test No fibre channel port selected Use a more recent version of diagnostics
420505 SCSI Tape, SCSI Self Test Could not access file Use a more recent version of diagnostics
420505 SCSI Tape, SCSI Self Test Invalid access order Select a different access order for this test
420505 SCSI Tape, SCSI Self Test Invalid parameter list Select different parameters for this test
420710 SCSI Tape, SCSI Self Test Could not access media Replace disk drive or media
420202 SCSI Tape, SCSI Self Test Cannot determine bus speed Check that Smart Array firmware and device drivers are up to date
420202 SCSI Tape, SCSI Self Test Cannot determine bus width Check that Smart Array firmware and device drivers are up to date
420505 SCSI Tape, SCSI Self Test SCSI command is not supported Use a more recent version of diagnostics
420505 SCSI Tape, SCSI Self Test SCSI adapter not implemented Use a more recent version of diagnostics
420710 SCSI Tape, SCSI Self Test Could not transfer SCSI data Check SCSI cables and connectors
420505 SCSI Tape, SCSI Self Test SCSI device not implemented Use a more recent version of diagnostics
420505 SCSI Tape, SCSI Self Test Undefined SCSI adapter Use a more recent version of diagnostics
420505 SCSI Tape, SCSI Self Test Device reported problem Use a more recent version of diagnostics
420505 SCSI Tape, SCSI Self Test Unknown device type Use a more recent version of diagnostics
420202 SCSI Tape, Bus Speed Test BMIC driver reported problem Check that Smart Array firmware and device drivers are up to date
420505 SCSI Tape, Bus Speed Test Cannot open filesystem table Use a more recent version of diagnostics
420303 SCSI Tape, Bus Speed Test CISS driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 SCSI Tape, Bus Speed Test Driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 SCSI Tape, Bus Speed Test Controller is not supported Check that Smart Array firmware and device drivers are up to date
420710 SCSI Tape, Bus Speed Test Error limit exceeded Replace disk drive or media
420505 SCSI Tape, Bus Speed Test No fibre channel port selected Use a more recent version of diagnostics
420505 SCSI Tape, Bus Speed Test Could not access file Use a more recent version of diagnostics
420505 SCSI Tape, Bus Speed Test Invalid access order Select a different access order for this test
420505 SCSI Tape, Bus Speed Test Invalid parameter list Select different parameters for this test
420710 SCSI Tape, Bus Speed Test Could not access media Replace disk drive or media
420202 SCSI Tape, Bus Speed Test Cannot determine bus speed Check that Smart Array firmware and device drivers are up to date
420202 SCSI Tape, Bus Speed Test Cannot determine bus width Check that Smart Array firmware and device drivers are up to date
420505 SCSI Tape, Bus Speed Test SCSI command is not supported Use a more recent version of diagnostics
420505 SCSI Tape, Bus Speed Test SCSI adapter not implemented Use a more recent version of diagnostics
420710 SCSI Tape, Bus Speed Test Could not transfer SCSI data Check SCSI cables and connectors
420505 SCSI Tape, Bus Speed Test SCSI device not implemented Use a more recent version of diagnostics
420505 SCSI Tape, Bus Speed Test Undefined SCSI adapter Use a more recent version of diagnostics
420505 SCSI Tape, Bus Speed Test Device reported problem Use a more recent version of diagnostics
420505 SCSI Tape, Bus Speed Test Unknown device type Use a more recent version of diagnostics
420202 SCSI Tape, Sequential Verify Test BMIC driver reported problem Check that Smart Array firmware and device drivers are up to date
420505 SCSI Tape, Sequential Verify Test Cannot open filesystem table Use a more recent version of diagnostics
420303 SCSI Tape, Sequential Verify Test CISS driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 SCSI Tape, Sequential Verify Test Driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 SCSI Tape, Sequential Verify Test Controller is not supported Check that Smart Array firmware and device drivers are up to date
420710 SCSI Tape, Sequential Verify Test Error limit exceeded Replace disk drive or media
420505 SCSI Tape, Sequential Verify Test No fibre channel port selected Use a more recent version of diagnostics
420505 SCSI Tape, Sequential Verify Test Could not access file Use a more recent version of diagnostics
420505 SCSI Tape, Sequential Verify Test Invalid access order Select a different access order for this test
420505 SCSI Tape, Sequential Verify Test Invalid parameter list Select different parameters for this test
420710 SCSI Tape, Sequential Verify Test Could not access media Replace disk drive or media
420202 SCSI Tape, Sequential Verify Test Cannot determine bus speed Check that Smart Array firmware and device drivers are up to date
420202 SCSI Tape, Sequential Verify Test Cannot determine bus width Check that Smart Array firmware and device drivers are up to date
420505 SCSI Tape, Sequential Verify Test SCSI command is not supported Use a more recent version of diagnostics
420505 SCSI Tape, Sequential Verify Test SCSI adapter not implemented Use a more recent version of diagnostics
420710 SCSI Tape, Sequential Verify Test Could not transfer SCSI data Check SCSI cables and connectors
420505 SCSI Tape, Sequential Verify Test SCSI device not implemented Use a more recent version of diagnostics
420505 SCSI Tape, Sequential Verify Test Undefined SCSI adapter Use a more recent version of diagnostics
420505 SCSI Tape, Sequential Verify Test Device reported problem Use a more recent version of diagnostics
420505 SCSI Tape, Sequential Verify Test Unknown device type Use a more recent version of diagnostics
420202 SCSI Tape, Sequential Read Test BMIC driver reported problem Check that Smart Array firmware and device drivers are up to date
420505 SCSI Tape, Sequential Read Test Cannot open filesystem table Use a more recent version of diagnostics
420303 SCSI Tape, Sequential Read Test CISS driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 SCSI Tape, Sequential Read Test Driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 SCSI Tape, Sequential Read Test Controller is not supported Check that Smart Array firmware and device drivers are up to date
420710 SCSI Tape, Sequential Read Test Error limit exceeded Replace disk drive or media
420505 SCSI Tape, Sequential Read Test No fibre channel port selected Use a more recent version of diagnostics
420505 SCSI Tape, Sequential Read Test Could not access file Use a more recent version of diagnostics
420505 SCSI Tape, Sequential Read Test Invalid access order Select a different access order for this test
420505 SCSI Tape, Sequential Read Test Invalid parameter list Select different parameters for this test
420710 SCSI Tape, Sequential Read Test Could not access media Replace disk drive or media
420202 SCSI Tape, Sequential Read Test Cannot determine bus speed Check that Smart Array firmware and device drivers are up to date
420202 SCSI Tape, Sequential Read Test Cannot determine bus width Check that Smart Array firmware and device drivers are up to date
420505 SCSI Tape, Sequential Read Test SCSI command is not supported Use a more recent version of diagnostics
420505 SCSI Tape, Sequential Read Test SCSI adapter not implemented Use a more recent version of diagnostics
420710 SCSI Tape, Sequential Read Test Could not transfer SCSI data Check SCSI cables and connectors
420505 SCSI Tape, Sequential Read Test SCSI device not implemented Use a more recent version of diagnostics
420505 SCSI Tape, Sequential Read Test Undefined SCSI adapter Use a more recent version of diagnostics
420505 SCSI Tape, Sequential Read Test Device reported problem Use a more recent version of diagnostics
420505 SCSI Tape, Sequential Read Test Unknown device type Use a more recent version of diagnostics
420202 SCSI Tape, Butterfly Read Test BMIC driver reported problem Check that Smart Array firmware and device drivers are up to date
420505 SCSI Tape, Butterfly Read Test Cannot open filesystem table Use a more recent version of diagnostics
420303 SCSI Tape, Butterfly Read Test CISS driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 SCSI Tape, Butterfly Read Test Driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 SCSI Tape, Butterfly Read Test Controller is not supported Check that Smart Array firmware and device drivers are up to date
420710 SCSI Tape, Butterfly Read Test Error limit exceeded Replace disk drive or media
420505 SCSI Tape, Butterfly Read Test No fibre channel port selected Use a more recent version of diagnostics
420505 SCSI Tape, Butterfly Read Test Could not access file Use a more recent version of diagnostics
420505 SCSI Tape, Butterfly Read Test Invalid access order Select a different access order for this test
420505 SCSI Tape, Butterfly Read Test Invalid parameter list Select different parameters for this test
420710 SCSI Tape, Butterfly Read Test Could not access media Replace disk drive or media
420202 SCSI Tape, Butterfly Read Test Cannot determine bus speed Check that Smart Array firmware and device drivers are up to date
420202 SCSI Tape, Butterfly Read Test Cannot determine bus width Check that Smart Array firmware and device drivers are up to date
420505 SCSI Tape, Butterfly Read Test SCSI command is not supported Use a more recent version of diagnostics
420505 SCSI Tape, Butterfly Read Test SCSI adapter not implemented Use a more recent version of diagnostics
420710 SCSI Tape, Butterfly Read Test Could not transfer SCSI data Check SCSI cables and connectors
420505 SCSI Tape, Butterfly Read Test SCSI device not implemented Use a more recent version of diagnostics
420505 SCSI Tape, Butterfly Read Test Undefined SCSI adapter Use a more recent version of diagnostics
420505 SCSI Tape, Butterfly Read Test Device reported problem Use a more recent version of diagnostics
420505 SCSI Tape, Butterfly Read Test Unknown device type Use a more recent version of diagnostics
420202 SCSI Tape, Random Read Test BMIC driver reported problem Check that Smart Array firmware and device drivers are up to date
420505 SCSI Tape, Random Read Test Cannot open filesystem table Use a more recent version of diagnostics
420303 SCSI Tape, Random Read Test CISS driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 SCSI Tape, Random Read Test Driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 SCSI Tape, Random Read Test Controller is not supported Check that Smart Array firmware and device drivers are up to date
420710 SCSI Tape, Random Read Test Error limit exceeded Replace disk drive or media
420505 SCSI Tape, Random Read Test No fibre channel port selected Use a more recent version of diagnostics
420505 SCSI Tape, Random Read Test Could not access file Use a more recent version of diagnostics
420505 SCSI Tape, Random Read Test Invalid access order Select a different access order for this test
420505 SCSI Tape, Random Read Test Invalid parameter list Select different parameters for this test
420710 SCSI Tape, Random Read Test Could not access media Replace disk drive or media
420202 SCSI Tape, Random Read Test Cannot determine bus speed Check that Smart Array firmware and device drivers are up to date
420202 SCSI Tape, Random Read Test Cannot determine bus width Check that Smart Array firmware and device drivers are up to date
420505 SCSI Tape, Random Read Test SCSI command is not supported Use a more recent version of diagnostics
420505 SCSI Tape, Random Read Test SCSI adapter not implemented Use a more recent version of diagnostics
420710 SCSI Tape, Random Read Test Could not transfer SCSI data Check SCSI cables and connectors
420505 SCSI Tape, Random Read Test SCSI device not implemented Use a more recent version of diagnostics
420505 SCSI Tape, Random Read Test Undefined SCSI adapter Use a more recent version of diagnostics
420505 SCSI Tape, Random Read Test Device reported problem Use a more recent version of diagnostics
420505 SCSI Tape, Random Read Test Unknown device type Use a more recent version of diagnostics
420202 SCSI Tape, Sequential Seek Test BMIC driver reported problem Check that Smart Array firmware and device drivers are up to date
420505 SCSI Tape, Sequential Seek Test Cannot open filesystem table Use a more recent version of diagnostics
420303 SCSI Tape, Sequential Seek Test CISS driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 SCSI Tape, Sequential Seek Test Driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 SCSI Tape, Sequential Seek Test Controller is not supported Check that Smart Array firmware and device drivers are up to date
420710 SCSI Tape, Sequential Seek Test Error limit exceeded Replace disk drive or media
420505 SCSI Tape, Sequential Seek Test No fibre channel port selected Use a more recent version of diagnostics
420505 SCSI Tape, Sequential Seek Test Could not access file Use a more recent version of diagnostics
420505 SCSI Tape, Sequential Seek Test Invalid access order Select a different access order for this test
420505 SCSI Tape, Sequential Seek Test Invalid parameter list Select different parameters for this test
420710 SCSI Tape, Sequential Seek Test Could not access media Replace disk drive or media
420202 SCSI Tape, Sequential Seek Test Cannot determine bus speed Check that Smart Array firmware and device drivers are up to date
420202 SCSI Tape, Sequential Seek Test Cannot determine bus width Check that Smart Array firmware and device drivers are up to date
420505 SCSI Tape, Sequential Seek Test SCSI command is not supported Use a more recent version of diagnostics
420505 SCSI Tape, Sequential Seek Test SCSI adapter not implemented Use a more recent version of diagnostics
420710 SCSI Tape, Sequential Seek Test Could not transfer SCSI data Check SCSI cables and connectors
420505 SCSI Tape, Sequential Seek Test SCSI device not implemented Use a more recent version of diagnostics
420505 SCSI Tape, Sequential Seek Test Undefined SCSI adapter Use a more recent version of diagnostics
420505 SCSI Tape, Sequential Seek Test Device reported problem Use a more recent version of diagnostics
420505 SCSI Tape, Sequential Seek Test Unknown device type Use a more recent version of diagnostics
420202 SCSI Tape, Butterfly Seek Test BMIC driver reported problem Check that Smart Array firmware and device drivers are up to date
420505 SCSI Tape, Butterfly Seek Test Cannot open filesystem table Use a more recent version of diagnostics
420303 SCSI Tape, Butterfly Seek Test CISS driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 SCSI Tape, Butterfly Seek Test Driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 SCSI Tape, Butterfly Seek Test Controller is not supported Check that Smart Array firmware and device drivers are up to date
420710 SCSI Tape, Butterfly Seek Test Error limit exceeded Replace disk drive or media
420505 SCSI Tape, Butterfly Seek Test No fibre channel port selected Use a more recent version of diagnostics
420505 SCSI Tape, Butterfly Seek Test Could not access file Use a more recent version of diagnostics
420505 SCSI Tape, Butterfly Seek Test Invalid access order Select a different access order for this test
420505 SCSI Tape, Butterfly Seek Test Invalid parameter list Select different parameters for this test
420710 SCSI Tape, Butterfly Seek Test Could not access media Replace disk drive or media
420202 SCSI Tape, Butterfly Seek Test Cannot determine bus speed Check that Smart Array firmware and device drivers are up to date
420202 SCSI Tape, Butterfly Seek Test Cannot determine bus width Check that Smart Array firmware and device drivers are up to date
420505 SCSI Tape, Butterfly Seek Test SCSI command is not supported Use a more recent version of diagnostics
420505 SCSI Tape, Butterfly Seek Test SCSI adapter not implemented Use a more recent version of diagnostics
420710 SCSI Tape, Butterfly Seek Test Could not transfer SCSI data Check SCSI cables and connectors
420505 SCSI Tape, Butterfly Seek Test SCSI device not implemented Use a more recent version of diagnostics
420505 SCSI Tape, Butterfly Seek Test Undefined SCSI adapter Use a more recent version of diagnostics
420505 SCSI Tape, Butterfly Seek Test Device reported problem Use a more recent version of diagnostics
420505 SCSI Tape, Butterfly Seek Test Unknown device type Use a more recent version of diagnostics
420202 SCSI Tape, Random Seek Test BMIC driver reported problem Check that Smart Array firmware and device drivers are up to date
420505 SCSI Tape, Random Seek Test Cannot open filesystem table Use a more recent version of diagnostics
420303 SCSI Tape, Random Seek Test CISS driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 SCSI Tape, Random Seek Test Driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 SCSI Tape, Random Seek Test Controller is not supported Check that Smart Array firmware and device drivers are up to date
420710 SCSI Tape, Random Seek Test Error limit exceeded Replace disk drive or media
420505 SCSI Tape, Random Seek Test No fibre channel port selected Use a more recent version of diagnostics
420505 SCSI Tape, Random Seek Test Could not access file Use a more recent version of diagnostics
420505 SCSI Tape, Random Seek Test Invalid access order Select a different access order for this test
420505 SCSI Tape, Random Seek Test Invalid parameter list Select different parameters for this test
420710 SCSI Tape, Random Seek Test Could not access media Replace disk drive or media
420202 SCSI Tape, Random Seek Test Cannot determine bus speed Check that Smart Array firmware and device drivers are up to date
420202 SCSI Tape, Random Seek Test Cannot determine bus width Check that Smart Array firmware and device drivers are up to date
420505 SCSI Tape, Random Seek Test SCSI command is not supported Use a more recent version of diagnostics
420505 SCSI Tape, Random Seek Test SCSI adapter not implemented Use a more recent version of diagnostics
420710 SCSI Tape, Random Seek Test Could not transfer SCSI data Check SCSI cables and connectors
420505 SCSI Tape, Random Seek Test SCSI device not implemented Use a more recent version of diagnostics
420505 SCSI Tape, Random Seek Test Undefined SCSI adapter Use a more recent version of diagnostics
420505 SCSI Tape, Random Seek Test Device reported problem Use a more recent version of diagnostics
420505 SCSI Tape, Random Seek Test Unknown device type Use a more recent version of diagnostics
420202 SCSI Tape, SCSI Tape Test Undefined Message Check that Smart Array firmware and device drivers are up to date
420505 SCSI Tape, SCSI Tape Test Undefined Message Use a more recent version of diagnostics
420303 SCSI Tape, SCSI Tape Test Undefined Message Check that Smart Array firmware and device drivers are up to date
420101 SCSI Tape, SCSI Tape Test Undefined Message Check that Smart Array firmware and device drivers are up to date
420101 SCSI Tape, SCSI Tape Test Undefined Message Check that Smart Array firmware and device drivers are up to date
420710 SCSI Tape, SCSI Tape Test Undefined Message Replace disk drive or media
420505 SCSI Tape, SCSI Tape Test Undefined Message Use a more recent version of diagnostics
420202 SCSI Controller, SCSI Self Test BMIC driver reported problem Check that Smart Array firmware and device drivers are up to date
420505 SCSI Controller, SCSI Self Test Cannot open filesystem table Use a more recent version of diagnostics
420303 SCSI Controller, SCSI Self Test CISS driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 SCSI Controller, SCSI Self Test Driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 SCSI Controller, SCSI Self Test Controller is not supported Check that Smart Array firmware and device drivers are up to date
420710 SCSI Controller, SCSI Self Test Error limit exceeded Replace disk drive or media
420505 SCSI Controller, SCSI Self Test No fibre channel port selected Use a more recent version of diagnostics
420505 SCSI Controller, SCSI Self Test Could not access file Use a more recent version of diagnostics
420505 SCSI Controller, SCSI Self Test Invalid access order Select a different access order for this test
420505 SCSI Controller, SCSI Self Test Invalid parameter list Select different parameters for this test
420710 SCSI Controller, SCSI Self Test Could not access media Replace disk drive or media
420202 SCSI Controller, SCSI Self Test Cannot determine bus speed Check that Smart Array firmware and device drivers are up to date
420202 SCSI Controller, SCSI Self Test Cannot determine bus width Check that Smart Array firmware and device drivers are up to date
420505 SCSI Controller, SCSI Self Test SCSI command is not supported Use a more recent version of diagnostics
420505 SCSI Controller, SCSI Self Test SCSI adapter not implemented Use a more recent version of diagnostics
420710 SCSI Controller, SCSI Self Test Could not transfer SCSI data Check SCSI cables and connectors
420505 SCSI Controller, SCSI Self Test SCSI device not implemented Use a more recent version of diagnostics
420505 SCSI Controller, SCSI Self Test Undefined SCSI adapter Use a more recent version of diagnostics
420505 SCSI Controller, SCSI Self Test Device reported problem Use a more recent version of diagnostics
420505 SCSI Controller, SCSI Self Test Unknown device type Use a more recent version of diagnostics
420202 SCSI Controller, Bus Speed Test BMIC driver reported problem Check that Smart Array firmware and device drivers are up to date
420505 SCSI Controller, Bus Speed Test Cannot open filesystem table Use a more recent version of diagnostics
420303 SCSI Controller, Bus Speed Test CISS driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 SCSI Controller, Bus Speed Test Driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 SCSI Controller, Bus Speed Test Controller is not supported Check that Smart Array firmware and device drivers are up to date
420710 SCSI Controller, Bus Speed Test Error limit exceeded Replace disk drive or media
420505 SCSI Controller, Bus Speed Test No fibre channel port selected Use a more recent version of diagnostics
420505 SCSI Controller, Bus Speed Test Could not access file Use a more recent version of diagnostics
420505 SCSI Controller, Bus Speed Test Invalid access order Select a different access order for this test
420505 SCSI Controller, Bus Speed Test Invalid parameter list Select different parameters for this test
420710 SCSI Controller, Bus Speed Test Could not access media Replace disk drive or media
420202 SCSI Controller, Bus Speed Test Cannot determine bus speed Check that Smart Array firmware and device drivers are up to date
420202 SCSI Controller, Bus Speed Test Cannot determine bus width Check that Smart Array firmware and device drivers are up to date
420505 SCSI Controller, Bus Speed Test SCSI command is not supported Use a more recent version of diagnostics
420505 SCSI Controller, Bus Speed Test SCSI adapter not implemented Use a more recent version of diagnostics
420710 SCSI Controller, Bus Speed Test Could not transfer SCSI data Check SCSI cables and connectors
420505 SCSI Controller, Bus Speed Test SCSI device not implemented Use a more recent version of diagnostics
420505 SCSI Controller, Bus Speed Test Undefined SCSI adapter Use a more recent version of diagnostics
420505 SCSI Controller, Bus Speed Test Device reported problem Use a more recent version of diagnostics
420505 SCSI Controller, Bus Speed Test Unknown device type Use a more recent version of diagnostics
420202 SCSI Controller, Sequential Read Test BMIC driver reported problem Check that Smart Array firmware and device drivers are up to date
420505 SCSI Controller, Sequential Read Test Cannot open filesystem table Use a more recent version of diagnostics
420303 SCSI Controller, Sequential Read Test CISS driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 SCSI Controller, Sequential Read Test Driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 SCSI Controller, Sequential Read Test Controller is not supported Check that Smart Array firmware and device drivers are up to date
420710 SCSI Controller, Sequential Read Test Error limit exceeded Replace disk drive or media
420505 SCSI Controller, Sequential Read Test No fibre channel port selected Use a more recent version of diagnostics
420505 SCSI Controller, Sequential Read Test Could not access file Use a more recent version of diagnostics
420505 SCSI Controller, Sequential Read Test Invalid access order Select a different access order for this test
420505 SCSI Controller, Sequential Read Test Invalid parameter list Select different parameters for this test
420710 SCSI Controller, Sequential Read Test Could not access media Replace disk drive or media
420202 SCSI Controller, Sequential Read Test Cannot determine bus speed Check that Smart Array firmware and device drivers are up to date
420202 SCSI Controller, Sequential Read Test Cannot determine bus width Check that Smart Array firmware and device drivers are up to date
420505 SCSI Controller, Sequential Read Test SCSI command is not supported Use a more recent version of diagnostics
420505 SCSI Controller, Sequential Read Test SCSI adapter not implemented Use a more recent version of diagnostics
420710 SCSI Controller, Sequential Read Test Could not transfer SCSI data Check SCSI cables and connectors
420505 SCSI Controller, Sequential Read Test SCSI device not implemented Use a more recent version of diagnostics
420505 SCSI Controller, Sequential Read Test Undefined SCSI adapter Use a more recent version of diagnostics
420505 SCSI Controller, Sequential Read Test Device reported problem Use a more recent version of diagnostics
420505 SCSI Controller, Sequential Read Test Unknown device type Use a more recent version of diagnostics
420202 SCSI Controller, Sequential Verify Test BMIC driver reported problem Check that Smart Array firmware and device drivers are up to date
420505 SCSI Controller, Sequential Verify Test Cannot open filesystem table Use a more recent version of diagnostics
420303 SCSI Controller, Sequential Verify Test CISS driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 SCSI Controller, Sequential Verify Test Driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 SCSI Controller, Sequential Verify Test Controller is not supported Check that Smart Array firmware and device drivers are up to date
420710 SCSI Controller, Sequential Verify Test Error limit exceeded Replace disk drive or media
420505 SCSI Controller, Sequential Verify Test No fibre channel port selected Use a more recent version of diagnostics
420505 SCSI Controller, Sequential Verify Test Could not access file Use a more recent version of diagnostics
420505 SCSI Controller, Sequential Verify Test Invalid access order Select a different access order for this test
420505 SCSI Controller, Sequential Verify Test Invalid parameter list Select different parameters for this test
420710 SCSI Controller, Sequential Verify Test Could not access media Replace disk drive or media
420202 SCSI Controller, Sequential Verify Test Cannot determine bus speed Check that Smart Array firmware and device drivers are up to date
420202 SCSI Controller, Sequential Verify Test Cannot determine bus width Check that Smart Array firmware and device drivers are up to date
420505 SCSI Controller, Sequential Verify Test SCSI command is not supported Use a more recent version of diagnostics
420505 SCSI Controller, Sequential Verify Test SCSI adapter not implemented Use a more recent version of diagnostics
420710 SCSI Controller, Sequential Verify Test Could not transfer SCSI data Check SCSI cables and connectors
420505 SCSI Controller, Sequential Verify Test SCSI device not implemented Use a more recent version of diagnostics
420505 SCSI Controller, Sequential Verify Test Undefined SCSI adapter Use a more recent version of diagnostics
420505 SCSI Controller, Sequential Verify Test Device reported problem Use a more recent version of diagnostics
420505 SCSI Controller, Sequential Verify Test Unknown device type Use a more recent version of diagnostics
420202 SCSI Controller, Butterfly Read Test BMIC driver reported problem Check that Smart Array firmware and device drivers are up to date
420505 SCSI Controller, Butterfly Read Test Cannot open filesystem table Use a more recent version of diagnostics
420303 SCSI Controller, Butterfly Read Test CISS driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 SCSI Controller, Butterfly Read Test Driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 SCSI Controller, Butterfly Read Test Controller is not supported Check that Smart Array firmware and device drivers are up to date
420710 SCSI Controller, Butterfly Read Test Error limit exceeded Replace disk drive or media
420505 SCSI Controller, Butterfly Read Test No fibre channel port selected Use a more recent version of diagnostics
420505 SCSI Controller, Butterfly Read Test Could not access file Use a more recent version of diagnostics
420505 SCSI Controller, Butterfly Read Test Invalid access order Select a different access order for this test
420505 SCSI Controller, Butterfly Read Test Invalid parameter list Select different parameters for this test
420710 SCSI Controller, Butterfly Read Test Could not access media Replace disk drive or media
420202 SCSI Controller, Butterfly Read Test Cannot determine bus speed Check that Smart Array firmware and device drivers are up to date
420202 SCSI Controller, Butterfly Read Test Cannot determine bus width Check that Smart Array firmware and device drivers are up to date
420505 SCSI Controller, Butterfly Read Test SCSI command is not supported Use a more recent version of diagnostics
420505 SCSI Controller, Butterfly Read Test SCSI adapter not implemented Use a more recent version of diagnostics
420710 SCSI Controller, Butterfly Read Test Could not transfer SCSI data Check SCSI cables and connectors
420505 SCSI Controller, Butterfly Read Test SCSI device not implemented Use a more recent version of diagnostics
420505 SCSI Controller, Butterfly Read Test Undefined SCSI adapter Use a more recent version of diagnostics
420505 SCSI Controller, Butterfly Read Test Device reported problem Use a more recent version of diagnostics
420505 SCSI Controller, Butterfly Read Test Unknown device type Use a more recent version of diagnostics
420202 SCSI Controller, Random Read Test BMIC driver reported problem Check that Smart Array firmware and device drivers are up to date
420505 SCSI Controller, Random Read Test Cannot open filesystem table Use a more recent version of diagnostics
420303 SCSI Controller, Random Read Test CISS driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 SCSI Controller, Random Read Test Driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 SCSI Controller, Random Read Test Controller is not supported Check that Smart Array firmware and device drivers are up to date
420710 SCSI Controller, Random Read Test Error limit exceeded Replace disk drive or media
420505 SCSI Controller, Random Read Test No fibre channel port selected Use a more recent version of diagnostics
420505 SCSI Controller, Random Read Test Could not access file Use a more recent version of diagnostics
420505 SCSI Controller, Random Read Test Invalid access order Select a different access order for this test
420505 SCSI Controller, Random Read Test Invalid parameter list Select different parameters for this test
420710 SCSI Controller, Random Read Test Could not access media Replace disk drive or media
420202 SCSI Controller, Random Read Test Cannot determine bus speed Check that Smart Array firmware and device drivers are up to date
420202 SCSI Controller, Random Read Test Cannot determine bus width Check that Smart Array firmware and device drivers are up to date
420505 SCSI Controller, Random Read Test SCSI command is not supported Use a more recent version of diagnostics
420505 SCSI Controller, Random Read Test SCSI adapter not implemented Use a more recent version of diagnostics
420710 SCSI Controller, Random Read Test Could not transfer SCSI data Check SCSI cables and connectors
420505 SCSI Controller, Random Read Test SCSI device not implemented Use a more recent version of diagnostics
420505 SCSI Controller, Random Read Test Undefined SCSI adapter Use a more recent version of diagnostics
420505 SCSI Controller, Random Read Test Device reported problem Use a more recent version of diagnostics
420505 SCSI Controller, Random Read Test Unknown device type Use a more recent version of diagnostics
420202 SCSI Controller, Sequential Seek Test BMIC driver reported problem Check that Smart Array firmware and device drivers are up to date
420505 SCSI Controller, Sequential Seek Test Cannot open filesystem table Use a more recent version of diagnostics
420303 SCSI Controller, Sequential Seek Test CISS driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 SCSI Controller, Sequential Seek Test Driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 SCSI Controller, Sequential Seek Test Controller is not supported Check that Smart Array firmware and device drivers are up to date
420710 SCSI Controller, Sequential Seek Test Error limit exceeded Replace disk drive or media
420505 SCSI Controller, Sequential Seek Test No fibre channel port selected Use a more recent version of diagnostics
420505 SCSI Controller, Sequential Seek Test Could not access file Use a more recent version of diagnostics
420505 SCSI Controller, Sequential Seek Test Invalid access order Select a different access order for this test
420505 SCSI Controller, Sequential Seek Test Invalid parameter list Select different parameters for this test
420710 SCSI Controller, Sequential Seek Test Could not access media Replace disk drive or media
420202 SCSI Controller, Sequential Seek Test Cannot determine bus speed Check that Smart Array firmware and device drivers are up to date
420202 SCSI Controller, Sequential Seek Test Cannot determine bus width Check that Smart Array firmware and device drivers are up to date
420505 SCSI Controller, Sequential Seek Test SCSI command is not supported Use a more recent version of diagnostics
420505 SCSI Controller, Sequential Seek Test SCSI adapter not implemented Use a more recent version of diagnostics
420710 SCSI Controller, Sequential Seek Test Could not transfer SCSI data Check SCSI cables and connectors
420505 SCSI Controller, Sequential Seek Test SCSI device not implemented Use a more recent version of diagnostics
420505 SCSI Controller, Sequential Seek Test Undefined SCSI adapter Use a more recent version of diagnostics
420505 SCSI Controller, Sequential Seek Test Device reported problem Use a more recent version of diagnostics
420505 SCSI Controller, Sequential Seek Test Unknown device type Use a more recent version of diagnostics
420202 SCSI Controller, Butterfly Seek Test BMIC driver reported problem Check that Smart Array firmware and device drivers are up to date
420505 SCSI Controller, Butterfly Seek Test Cannot open filesystem table Use a more recent version of diagnostics
420303 SCSI Controller, Butterfly Seek Test CISS driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 SCSI Controller, Butterfly Seek Test Driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 SCSI Controller, Butterfly Seek Test Controller is not supported Check that Smart Array firmware and device drivers are up to date
420710 SCSI Controller, Butterfly Seek Test Error limit exceeded Replace disk drive or media
420505 SCSI Controller, Butterfly Seek Test No fibre channel port selected Use a more recent version of diagnostics
420505 SCSI Controller, Butterfly Seek Test Could not access file Use a more recent version of diagnostics
420505 SCSI Controller, Butterfly Seek Test Invalid access order Select a different access order for this test
420505 SCSI Controller, Butterfly Seek Test Invalid parameter list Select different parameters for this test
420710 SCSI Controller, Butterfly Seek Test Could not access media Replace disk drive or media
420202 SCSI Controller, Butterfly Seek Test Cannot determine bus speed Check that Smart Array firmware and device drivers are up to date
420202 SCSI Controller, Butterfly Seek Test Cannot determine bus width Check that Smart Array firmware and device drivers are up to date
420505 SCSI Controller, Butterfly Seek Test SCSI command is not supported Use a more recent version of diagnostics
420505 SCSI Controller, Butterfly Seek Test SCSI adapter not implemented Use a more recent version of diagnostics
420710 SCSI Controller, Butterfly Seek Test Could not transfer SCSI data Check SCSI cables and connectors
420505 SCSI Controller, Butterfly Seek Test SCSI device not implemented Use a more recent version of diagnostics
420505 SCSI Controller, Butterfly Seek Test Undefined SCSI adapter Use a more recent version of diagnostics
420505 SCSI Controller, Butterfly Seek Test Device reported problem Use a more recent version of diagnostics
420505 SCSI Controller, Butterfly Seek Test Unknown device type Use a more recent version of diagnostics
420202 SCSI Controller, Random Seek Test BMIC driver reported problem Check that Smart Array firmware and device drivers are up to date
420505 SCSI Controller, Random Seek Test Cannot open filesystem table Use a more recent version of diagnostics
420303 SCSI Controller, Random Seek Test CISS driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 SCSI Controller, Random Seek Test Driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 SCSI Controller, Random Seek Test Controller is not supported Check that Smart Array firmware and device drivers are up to date
420710 SCSI Controller, Random Seek Test Error limit exceeded Replace disk drive or media
420505 SCSI Controller, Random Seek Test No fibre channel port selected Use a more recent version of diagnostics
420505 SCSI Controller, Random Seek Test Could not access file Use a more recent version of diagnostics
420505 SCSI Controller, Random Seek Test Invalid access order Select a different access order for this test
420505 SCSI Controller, Random Seek Test Invalid parameter list Select different parameters for this test
420710 SCSI Controller, Random Seek Test Could not access media Replace disk drive or media
420202 SCSI Controller, Random Seek Test Cannot determine bus speed Check that Smart Array firmware and device drivers are up to date
420202 SCSI Controller, Random Seek Test Cannot determine bus width Check that Smart Array firmware and device drivers are up to date
420505 SCSI Controller, Random Seek Test SCSI command is not supported Use a more recent version of diagnostics
420505 SCSI Controller, Random Seek Test SCSI adapter not implemented Use a more recent version of diagnostics
420710 SCSI Controller, Random Seek Test Could not transfer SCSI data Check SCSI cables and connectors
420505 SCSI Controller, Random Seek Test SCSI device not implemented Use a more recent version of diagnostics
420505 SCSI Controller, Random Seek Test Undefined SCSI adapter Use a more recent version of diagnostics
420505 SCSI Controller, Random Seek Test Device reported problem Use a more recent version of diagnostics
420505 SCSI Controller, Random Seek Test Unknown device type Use a more recent version of diagnostics
420202 Fibre Adapter, SCSI Self Test BMIC driver reported problem Check that Smart Array firmware and device drivers are up to date
420505 Fibre Adapter, SCSI Self Test Cannot open filesystem table Use a more recent version of diagnostics
420303 Fibre Adapter, SCSI Self Test CISS driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Fibre Adapter, SCSI Self Test Driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Fibre Adapter, SCSI Self Test Controller is not supported Check that Smart Array firmware and device drivers are up to date
420710 Fibre Adapter, SCSI Self Test Error limit exceeded Replace disk drive or media
420505 Fibre Adapter, SCSI Self Test No fibre channel port selected Use a more recent version of diagnostics
420505 Fibre Adapter, SCSI Self Test Could not access file Use a more recent version of diagnostics
420505 Fibre Adapter, SCSI Self Test Invalid access order Select a different access order for this test
420505 Fibre Adapter, SCSI Self Test Invalid parameter list Select different parameters for this test
420710 Fibre Adapter, SCSI Self Test Could not access media Replace disk drive or media
420202 Fibre Adapter, SCSI Self Test Cannot determine bus speed Check that Smart Array firmware and device drivers are up to date
420202 Fibre Adapter, SCSI Self Test Cannot determine bus width Check that Smart Array firmware and device drivers are up to date
420505 Fibre Adapter, SCSI Self Test SCSI command is not supported Use a more recent version of diagnostics
420505 Fibre Adapter, SCSI Self Test SCSI adapter not implemented Use a more recent version of diagnostics
420710 Fibre Adapter, SCSI Self Test Could not transfer SCSI data Check SCSI cables and connectors
420505 Fibre Adapter, SCSI Self Test SCSI device not implemented Use a more recent version of diagnostics
420505 Fibre Adapter, SCSI Self Test Undefined SCSI adapter Use a more recent version of diagnostics
420505 Fibre Adapter, SCSI Self Test Device reported problem Use a more recent version of diagnostics
420505 Fibre Adapter, SCSI Self Test Unknown device type Use a more recent version of diagnostics
420202 Fibre Adapter, Bus Speed Test BMIC driver reported problem Check that Smart Array firmware and device drivers are up to date
420505 Fibre Adapter, Bus Speed Test Cannot open filesystem table Use a more recent version of diagnostics
420303 Fibre Adapter, Bus Speed Test CISS driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Fibre Adapter, Bus Speed Test Driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Fibre Adapter, Bus Speed Test Controller is not supported Check that Smart Array firmware and device drivers are up to date
420710 Fibre Adapter, Bus Speed Test Error limit exceeded Replace disk drive or media
420505 Fibre Adapter, Bus Speed Test No fibre channel port selected Use a more recent version of diagnostics
420505 Fibre Adapter, Bus Speed Test Could not access file Use a more recent version of diagnostics
420505 Fibre Adapter, Bus Speed Test Invalid access order Select a different access order for this test
420505 Fibre Adapter, Bus Speed Test Invalid parameter list Select different parameters for this test
420710 Fibre Adapter, Bus Speed Test Could not access media Replace disk drive or media
420202 Fibre Adapter, Bus Speed Test Cannot determine bus speed Check that Smart Array firmware and device drivers are up to date
420202 Fibre Adapter, Bus Speed Test Cannot determine bus width Check that Smart Array firmware and device drivers are up to date
420505 Fibre Adapter, Bus Speed Test SCSI command is not supported Use a more recent version of diagnostics
420505 Fibre Adapter, Bus Speed Test SCSI adapter not implemented Use a more recent version of diagnostics
420710 Fibre Adapter, Bus Speed Test Could not transfer SCSI data Check SCSI cables and connectors
420505 Fibre Adapter, Bus Speed Test SCSI device not implemented Use a more recent version of diagnostics
420505 Fibre Adapter, Bus Speed Test Undefined SCSI adapter Use a more recent version of diagnostics
420505 Fibre Adapter, Bus Speed Test Device reported problem Use a more recent version of diagnostics
420505 Fibre Adapter, Bus Speed Test Unknown device type Use a more recent version of diagnostics
420202 Fibre Adapter, Sequential Verify Test BMIC driver reported problem Check that Smart Array firmware and device drivers are up to date
420505 Fibre Adapter, Sequential Verify Test Cannot open filesystem table Use a more recent version of diagnostics
420303 Fibre Adapter, Sequential Verify Test CISS driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Fibre Adapter, Sequential Verify Test Driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Fibre Adapter, Sequential Verify Test Controller is not supported Check that Smart Array firmware and device drivers are up to date
420710 Fibre Adapter, Sequential Verify Test Error limit exceeded Replace disk drive or media
420505 Fibre Adapter, Sequential Verify Test No fibre channel port selected Use a more recent version of diagnostics
420505 Fibre Adapter, Sequential Verify Test Could not access file Use a more recent version of diagnostics
420505 Fibre Adapter, Sequential Verify Test Invalid access order Select a different access order for this test
420505 Fibre Adapter, Sequential Verify Test Invalid parameter list Select different parameters for this test
420710 Fibre Adapter, Sequential Verify Test Could not access media Replace disk drive or media
420202 Fibre Adapter, Sequential Verify Test Cannot determine bus speed Check that Smart Array firmware and device drivers are up to date
420202 Fibre Adapter, Sequential Verify Test Cannot determine bus width Check that Smart Array firmware and device drivers are up to date
420505 Fibre Adapter, Sequential Verify Test SCSI command is not supported Use a more recent version of diagnostics
420505 Fibre Adapter, Sequential Verify Test SCSI adapter not implemented Use a more recent version of diagnostics
420710 Fibre Adapter, Sequential Verify Test Could not transfer SCSI data Check SCSI cables and connectors
420505 Fibre Adapter, Sequential Verify Test SCSI device not implemented Use a more recent version of diagnostics
420505 Fibre Adapter, Sequential Verify Test Undefined SCSI adapter Use a more recent version of diagnostics
420505 Fibre Adapter, Sequential Verify Test Device reported problem Use a more recent version of diagnostics
420505 Fibre Adapter, Sequential Verify Test Unknown device type Use a more recent version of diagnostics
420202 Fibre Adapter, Sequential Read Test BMIC driver reported problem Check that Smart Array firmware and device drivers are up to date
420505 Fibre Adapter, Sequential Read Test Cannot open filesystem table Use a more recent version of diagnostics
420303 Fibre Adapter, Sequential Read Test CISS driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Fibre Adapter, Sequential Read Test Driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Fibre Adapter, Sequential Read Test Controller is not supported Check that Smart Array firmware and device drivers are up to date
420710 Fibre Adapter, Sequential Read Test Error limit exceeded Replace disk drive or media
420505 Fibre Adapter, Sequential Read Test No fibre channel port selected Use a more recent version of diagnostics
420505 Fibre Adapter, Sequential Read Test Could not access file Use a more recent version of diagnostics
420505 Fibre Adapter, Sequential Read Test Invalid access order Select a different access order for this test
420505 Fibre Adapter, Sequential Read Test Invalid parameter list Select different parameters for this test
420710 Fibre Adapter, Sequential Read Test Could not access media Replace disk drive or media
420202 Fibre Adapter, Sequential Read Test Cannot determine bus speed Check that Smart Array firmware and device drivers are up to date
420202 Fibre Adapter, Sequential Read Test Cannot determine bus width Check that Smart Array firmware and device drivers are up to date
420505 Fibre Adapter, Sequential Read Test SCSI command is not supported Use a more recent version of diagnostics
420505 Fibre Adapter, Sequential Read Test SCSI adapter not implemented Use a more recent version of diagnostics
420710 Fibre Adapter, Sequential Read Test Could not transfer SCSI data Check SCSI cables and connectors
420505 Fibre Adapter, Sequential Read Test SCSI device not implemented Use a more recent version of diagnostics
420505 Fibre Adapter, Sequential Read Test Undefined SCSI adapter Use a more recent version of diagnostics
420505 Fibre Adapter, Sequential Read Test Device reported problem Use a more recent version of diagnostics
420505 Fibre Adapter, Sequential Read Test Unknown device type Use a more recent version of diagnostics
420202 Fibre Adapter, Butterfly Read Test BMIC driver reported problem Check that Smart Array firmware and device drivers are up to date
420505 Fibre Adapter, Butterfly Read Test Cannot open filesystem table Use a more recent version of diagnostics
420303 Fibre Adapter, Butterfly Read Test CISS driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Fibre Adapter, Butterfly Read Test Driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Fibre Adapter, Butterfly Read Test Controller is not supported Check that Smart Array firmware and device drivers are up to date
420710 Fibre Adapter, Butterfly Read Test Error limit exceeded Replace disk drive or media
420505 Fibre Adapter, Butterfly Read Test No fibre channel port selected Use a more recent version of diagnostics
420505 Fibre Adapter, Butterfly Read Test Could not access file Use a more recent version of diagnostics
420505 Fibre Adapter, Butterfly Read Test Invalid access order Select a different access order for this test
420505 Fibre Adapter, Butterfly Read Test Invalid parameter list Select different parameters for this test
420710 Fibre Adapter, Butterfly Read Test Could not access media Replace disk drive or media
420202 Fibre Adapter, Butterfly Read Test Cannot determine bus speed Check that Smart Array firmware and device drivers are up to date
420202 Fibre Adapter, Butterfly Read Test Cannot determine bus width Check that Smart Array firmware and device drivers are up to date
420505 Fibre Adapter, Butterfly Read Test SCSI command is not supported Use a more recent version of diagnostics
420505 Fibre Adapter, Butterfly Read Test SCSI adapter not implemented Use a more recent version of diagnostics
420710 Fibre Adapter, Butterfly Read Test Could not transfer SCSI data Check SCSI cables and connectors
420505 Fibre Adapter, Butterfly Read Test SCSI device not implemented Use a more recent version of diagnostics
420505 Fibre Adapter, Butterfly Read Test Undefined SCSI adapter Use a more recent version of diagnostics
420505 Fibre Adapter, Butterfly Read Test Device reported problem Use a more recent version of diagnostics
420505 Fibre Adapter, Butterfly Read Test Unknown device type Use a more recent version of diagnostics
420202 Fibre Adapter, Random Read Test BMIC driver reported problem Check that Smart Array firmware and device drivers are up to date
420505 Fibre Adapter, Random Read Test Cannot open filesystem table Use a more recent version of diagnostics
420303 Fibre Adapter, Random Read Test CISS driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Fibre Adapter, Random Read Test Driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Fibre Adapter, Random Read Test Controller is not supported Check that Smart Array firmware and device drivers are up to date
420710 Fibre Adapter, Random Read Test Error limit exceeded Replace disk drive or media
420505 Fibre Adapter, Random Read Test No fibre channel port selected Use a more recent version of diagnostics
420505 Fibre Adapter, Random Read Test Could not access file Use a more recent version of diagnostics
420505 Fibre Adapter, Random Read Test Invalid access order Select a different access order for this test
420505 Fibre Adapter, Random Read Test Invalid parameter list Select different parameters for this test
420710 Fibre Adapter, Random Read Test Could not access media Replace disk drive or media
420202 Fibre Adapter, Random Read Test Cannot determine bus speed Check that Smart Array firmware and device drivers are up to date
420202 Fibre Adapter, Random Read Test Cannot determine bus width Check that Smart Array firmware and device drivers are up to date
420505 Fibre Adapter, Random Read Test SCSI command is not supported Use a more recent version of diagnostics
420505 Fibre Adapter, Random Read Test SCSI adapter not implemented Use a more recent version of diagnostics
420710 Fibre Adapter, Random Read Test Could not transfer SCSI data Check SCSI cables and connectors
420505 Fibre Adapter, Random Read Test SCSI device not implemented Use a more recent version of diagnostics
420505 Fibre Adapter, Random Read Test Undefined SCSI adapter Use a more recent version of diagnostics
420505 Fibre Adapter, Random Read Test Device reported problem Use a more recent version of diagnostics
420505 Fibre Adapter, Random Read Test Unknown device type Use a more recent version of diagnostics
420202 Fibre Adapter, Sequential Seek Test BMIC driver reported problem Check that Smart Array firmware and device drivers are up to date
420505 Fibre Adapter, Sequential Seek Test Cannot open filesystem table Use a more recent version of diagnostics
420303 Fibre Adapter, Sequential Seek Test CISS driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Fibre Adapter, Sequential Seek Test Driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Fibre Adapter, Sequential Seek Test Controller is not supported Check that Smart Array firmware and device drivers are up to date
420710 Fibre Adapter, Sequential Seek Test Error limit exceeded Replace disk drive or media
420505 Fibre Adapter, Sequential Seek Test No fibre channel port selected Use a more recent version of diagnostics
420505 Fibre Adapter, Sequential Seek Test Could not access file Use a more recent version of diagnostics
420505 Fibre Adapter, Sequential Seek Test Invalid access order Select a different access order for this test
420505 Fibre Adapter, Sequential Seek Test Invalid parameter list Select different parameters for this test
420710 Fibre Adapter, Sequential Seek Test Could not access media Replace disk drive or media
420202 Fibre Adapter, Sequential Seek Test Cannot determine bus speed Check that Smart Array firmware and device drivers are up to date
420202 Fibre Adapter, Sequential Seek Test Cannot determine bus width Check that Smart Array firmware and device drivers are up to date
420505 Fibre Adapter, Sequential Seek Test SCSI command is not supported Use a more recent version of diagnostics
420505 Fibre Adapter, Sequential Seek Test SCSI adapter not implemented Use a more recent version of diagnostics
420710 Fibre Adapter, Sequential Seek Test Could not transfer SCSI data Check SCSI cables and connectors
420505 Fibre Adapter, Sequential Seek Test SCSI device not implemented Use a more recent version of diagnostics
420505 Fibre Adapter, Sequential Seek Test Undefined SCSI adapter Use a more recent version of diagnostics
420505 Fibre Adapter, Sequential Seek Test Device reported problem Use a more recent version of diagnostics
420505 Fibre Adapter, Sequential Seek Test Unknown device type Use a more recent version of diagnostics
420202 Fibre Adapter, Butterfly Seek Test BMIC driver reported problem Check that Smart Array firmware and device drivers are up to date
420505 Fibre Adapter, Butterfly Seek Test Cannot open filesystem table Use a more recent version of diagnostics
420303 Fibre Adapter, Butterfly Seek Test CISS driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Fibre Adapter, Butterfly Seek Test Driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Fibre Adapter, Butterfly Seek Test Controller is not supported Check that Smart Array firmware and device drivers are up to date
420710 Fibre Adapter, Butterfly Seek Test Error limit exceeded Replace disk drive or media
420505 Fibre Adapter, Butterfly Seek Test No fibre channel port selected Use a more recent version of diagnostics
420505 Fibre Adapter, Butterfly Seek Test Could not access file Use a more recent version of diagnostics
420505 Fibre Adapter, Butterfly Seek Test Invalid access order Select a different access order for this test
420505 Fibre Adapter, Butterfly Seek Test Invalid parameter list Select different parameters for this test
420710 Fibre Adapter, Butterfly Seek Test Could not access media Replace disk drive or media
420202 Fibre Adapter, Butterfly Seek Test Cannot determine bus speed Check that Smart Array firmware and device drivers are up to date
420202 Fibre Adapter, Butterfly Seek Test Cannot determine bus width Check that Smart Array firmware and device drivers are up to date
420505 Fibre Adapter, Butterfly Seek Test SCSI command is not supported Use a more recent version of diagnostics
420505 Fibre Adapter, Butterfly Seek Test SCSI adapter not implemented Use a more recent version of diagnostics
420710 Fibre Adapter, Butterfly Seek Test Could not transfer SCSI data Check SCSI cables and connectors
420505 Fibre Adapter, Butterfly Seek Test SCSI device not implemented Use a more recent version of diagnostics
420505 Fibre Adapter, Butterfly Seek Test Undefined SCSI adapter Use a more recent version of diagnostics
420505 Fibre Adapter, Butterfly Seek Test Device reported problem Use a more recent version of diagnostics
420505 Fibre Adapter, Butterfly Seek Test Unknown device type Use a more recent version of diagnostics
420202 Fibre Adapter, Random Seek Test BMIC driver reported problem Check that Smart Array firmware and device drivers are up to date
420505 Fibre Adapter, Random Seek Test Cannot open filesystem table Use a more recent version of diagnostics
420303 Fibre Adapter, Random Seek Test CISS driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Fibre Adapter, Random Seek Test Driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Fibre Adapter, Random Seek Test Controller is not supported Check that Smart Array firmware and device drivers are up to date
420710 Fibre Adapter, Random Seek Test Error limit exceeded Replace disk drive or media
420505 Fibre Adapter, Random Seek Test No fibre channel port selected Use a more recent version of diagnostics
420505 Fibre Adapter, Random Seek Test Could not access file Use a more recent version of diagnostics
420505 Fibre Adapter, Random Seek Test Invalid access order Select a different access order for this test
420505 Fibre Adapter, Random Seek Test Invalid parameter list Select different parameters for this test
420710 Fibre Adapter, Random Seek Test Could not access media Replace disk drive or media
420202 Fibre Adapter, Random Seek Test Cannot determine bus speed Check that Smart Array firmware and device drivers are up to date
420202 Fibre Adapter, Random Seek Test Cannot determine bus width Check that Smart Array firmware and device drivers are up to date
420505 Fibre Adapter, Random Seek Test SCSI command is not supported Use a more recent version of diagnostics
420505 Fibre Adapter, Random Seek Test SCSI adapter not implemented Use a more recent version of diagnostics
420710 Fibre Adapter, Random Seek Test Could not transfer SCSI data Check SCSI cables and connectors
420505 Fibre Adapter, Random Seek Test SCSI device not implemented Use a more recent version of diagnostics
420505 Fibre Adapter, Random Seek Test Undefined SCSI adapter Use a more recent version of diagnostics
420505 Fibre Adapter, Random Seek Test Device reported problem Use a more recent version of diagnostics
420505 Fibre Adapter, Random Seek Test Unknown device type Use a more recent version of diagnostics
420202 Fibre Array Controller, SCSI Self Test BMIC driver reported problem Check that Smart Array firmware and device drivers are up to date
420505 Fibre Array Controller, SCSI Self Test Cannot open filesystem table Use a more recent version of diagnostics
420303 Fibre Array Controller, SCSI Self Test CISS driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Fibre Array Controller, SCSI Self Test Driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Fibre Array Controller, SCSI Self Test Controller is not supported Check that Smart Array firmware and device drivers are up to date
420710 Fibre Array Controller, SCSI Self Test Error limit exceeded Replace disk drive or media
420505 Fibre Array Controller, SCSI Self Test No fibre channel port selected Use a more recent version of diagnostics
420505 Fibre Array Controller, SCSI Self Test Could not access file Use a more recent version of diagnostics
420505 Fibre Array Controller, SCSI Self Test Invalid access order Select a different access order for this test
420505 Fibre Array Controller, SCSI Self Test Invalid parameter list Select different parameters for this test
420710 Fibre Array Controller, SCSI Self Test Could not access media Replace disk drive or media
420202 Fibre Array Controller, SCSI Self Test Cannot determine bus speed Check that Smart Array firmware and device drivers are up to date
420202 Fibre Array Controller, SCSI Self Test Cannot determine bus width Check that Smart Array firmware and device drivers are up to date
420505 Fibre Array Controller, SCSI Self Test SCSI command is not supported Use a more recent version of diagnostics
420505 Fibre Array Controller, SCSI Self Test SCSI adapter not implemented Use a more recent version of diagnostics
420710 Fibre Array Controller, SCSI Self Test Could not transfer SCSI data Check SCSI cables and connectors
420505 Fibre Array Controller, SCSI Self Test SCSI device not implemented Use a more recent version of diagnostics
420505 Fibre Array Controller, SCSI Self Test Undefined SCSI adapter Use a more recent version of diagnostics
420505 Fibre Array Controller, SCSI Self Test Device reported problem Use a more recent version of diagnostics
420505 Fibre Array Controller, SCSI Self Test Unknown device type Use a more recent version of diagnostics
420202 Fibre Array Controller, Bus Speed Test BMIC driver reported problem Check that Smart Array firmware and device drivers are up to date
420505 Fibre Array Controller, Bus Speed Test Cannot open filesystem table Use a more recent version of diagnostics
420303 Fibre Array Controller, Bus Speed Test CISS driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Fibre Array Controller, Bus Speed Test Driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Fibre Array Controller, Bus Speed Test Controller is not supported Check that Smart Array firmware and device drivers are up to date
420710 Fibre Array Controller, Bus Speed Test Error limit exceeded Replace disk drive or media
420505 Fibre Array Controller, Bus Speed Test No fibre channel port selected Use a more recent version of diagnostics
420505 Fibre Array Controller, Bus Speed Test Could not access file Use a more recent version of diagnostics
420505 Fibre Array Controller, Bus Speed Test Invalid access order Select a different access order for this test
420505 Fibre Array Controller, Bus Speed Test Invalid parameter list Select different parameters for this test
420710 Fibre Array Controller, Bus Speed Test Could not access media Replace disk drive or media
420202 Fibre Array Controller, Bus Speed Test Cannot determine bus speed Check that Smart Array firmware and device drivers are up to date
420202 Fibre Array Controller, Bus Speed Test Cannot determine bus width Check that Smart Array firmware and device drivers are up to date
420505 Fibre Array Controller, Bus Speed Test SCSI command is not supported Use a more recent version of diagnostics
420505 Fibre Array Controller, Bus Speed Test SCSI adapter not implemented Use a more recent version of diagnostics
420710 Fibre Array Controller, Bus Speed Test Could not transfer SCSI data Check SCSI cables and connectors
420505 Fibre Array Controller, Bus Speed Test SCSI device not implemented Use a more recent version of diagnostics
420505 Fibre Array Controller, Bus Speed Test Undefined SCSI adapter Use a more recent version of diagnostics
420505 Fibre Array Controller, Bus Speed Test Device reported problem Use a more recent version of diagnostics
420505 Fibre Array Controller, Bus Speed Test Unknown device type Use a more recent version of diagnostics
420202 Fibre Array Controller, Sequential Verify Test BMIC driver reported problem Check that Smart Array firmware and device drivers are up to date
420505 Fibre Array Controller, Sequential Verify Test Cannot open filesystem table Use a more recent version of diagnostics
420303 Fibre Array Controller, Sequential Verify Test CISS driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Fibre Array Controller, Sequential Verify Test Driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Fibre Array Controller, Sequential Verify Test Controller is not supported Check that Smart Array firmware and device drivers are up to date
420710 Fibre Array Controller, Sequential Verify Test Error limit exceeded Replace disk drive or media
420505 Fibre Array Controller, Sequential Verify Test No fibre channel port selected Use a more recent version of diagnostics
420505 Fibre Array Controller, Sequential Verify Test Could not access file Use a more recent version of diagnostics
420505 Fibre Array Controller, Sequential Verify Test Invalid access order Select a different access order for this test
420505 Fibre Array Controller, Sequential Verify Test Invalid parameter list Select different parameters for this test
420710 Fibre Array Controller, Sequential Verify Test Could not access media Replace disk drive or media
420202 Fibre Array Controller, Sequential Verify Test Cannot determine bus speed Check that Smart Array firmware and device drivers are up to date
420202 Fibre Array Controller, Sequential Verify Test Cannot determine bus width Check that Smart Array firmware and device drivers are up to date
420505 Fibre Array Controller, Sequential Verify Test SCSI command is not supported Use a more recent version of diagnostics
420505 Fibre Array Controller, Sequential Verify Test SCSI adapter not implemented Use a more recent version of diagnostics
420710 Fibre Array Controller, Sequential Verify Test Could not transfer SCSI data Check SCSI cables and connectors
420505 Fibre Array Controller, Sequential Verify Test SCSI device not implemented Use a more recent version of diagnostics
420505 Fibre Array Controller, Sequential Verify Test Undefined SCSI adapter Use a more recent version of diagnostics
420505 Fibre Array Controller, Sequential Verify Test Device reported problem Use a more recent version of diagnostics
420505 Fibre Array Controller, Sequential Verify Test Unknown device type Use a more recent version of diagnostics
420202 Fibre Array Controller, Sequential Read Test BMIC driver reported problem Check that Smart Array firmware and device drivers are up to date
420505 Fibre Array Controller, Sequential Read Test Cannot open filesystem table Use a more recent version of diagnostics
420303 Fibre Array Controller, Sequential Read Test CISS driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Fibre Array Controller, Sequential Read Test Driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Fibre Array Controller, Sequential Read Test Controller is not supported Check that Smart Array firmware and device drivers are up to date
420710 Fibre Array Controller, Sequential Read Test Error limit exceeded Replace disk drive or media
420505 Fibre Array Controller, Sequential Read Test No fibre channel port selected Use a more recent version of diagnostics
420505 Fibre Array Controller, Sequential Read Test Could not access file Use a more recent version of diagnostics
420505 Fibre Array Controller, Sequential Read Test Invalid access order Select a different access order for this test
420505 Fibre Array Controller, Sequential Read Test Invalid parameter list Select different parameters for this test
420710 Fibre Array Controller, Sequential Read Test Could not access media Replace disk drive or media
420202 Fibre Array Controller, Sequential Read Test Cannot determine bus speed Check that Smart Array firmware and device drivers are up to date
420202 Fibre Array Controller, Sequential Read Test Cannot determine bus width Check that Smart Array firmware and device drivers are up to date
420505 Fibre Array Controller, Sequential Read Test SCSI command is not supported Use a more recent version of diagnostics
420505 Fibre Array Controller, Sequential Read Test SCSI adapter not implemented Use a more recent version of diagnostics
420710 Fibre Array Controller, Sequential Read Test Could not transfer SCSI data Check SCSI cables and connectors
420505 Fibre Array Controller, Sequential Read Test SCSI device not implemented Use a more recent version of diagnostics
420505 Fibre Array Controller, Sequential Read Test Undefined SCSI adapter Use a more recent version of diagnostics
420505 Fibre Array Controller, Sequential Read Test Device reported problem Use a more recent version of diagnostics
420505 Fibre Array Controller, Sequential Read Test Unknown device type Use a more recent version of diagnostics
420202 Fibre Array Controller, Butterfly Read Test BMIC driver reported problem Check that Smart Array firmware and device drivers are up to date
420505 Fibre Array Controller, Butterfly Read Test Cannot open filesystem table Use a more recent version of diagnostics
420303 Fibre Array Controller, Butterfly Read Test CISS driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Fibre Array Controller, Butterfly Read Test Driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Fibre Array Controller, Butterfly Read Test Controller is not supported Check that Smart Array firmware and device drivers are up to date
420710 Fibre Array Controller, Butterfly Read Test Error limit exceeded Replace disk drive or media
420505 Fibre Array Controller, Butterfly Read Test No fibre channel port selected Use a more recent version of diagnostics
420505 Fibre Array Controller, Butterfly Read Test Could not access file Use a more recent version of diagnostics
420505 Fibre Array Controller, Butterfly Read Test Invalid access order Select a different access order for this test
420505 Fibre Array Controller, Butterfly Read Test Invalid parameter list Select different parameters for this test
420710 Fibre Array Controller, Butterfly Read Test Could not access media Replace disk drive or media
420202 Fibre Array Controller, Butterfly Read Test Cannot determine bus speed Check that Smart Array firmware and device drivers are up to date
420202 Fibre Array Controller, Butterfly Read Test Cannot determine bus width Check that Smart Array firmware and device drivers are up to date
420505 Fibre Array Controller, Butterfly Read Test SCSI command is not supported Use a more recent version of diagnostics
420505 Fibre Array Controller, Butterfly Read Test SCSI adapter not implemented Use a more recent version of diagnostics
420710 Fibre Array Controller, Butterfly Read Test Could not transfer SCSI data Check SCSI cables and connectors
420505 Fibre Array Controller, Butterfly Read Test SCSI device not implemented Use a more recent version of diagnostics
420505 Fibre Array Controller, Butterfly Read Test Undefined SCSI adapter Use a more recent version of diagnostics
420505 Fibre Array Controller, Butterfly Read Test Device reported problem Use a more recent version of diagnostics
420505 Fibre Array Controller, Butterfly Read Test Unknown device type Use a more recent version of diagnostics
420202 Fibre Array Controller, Random Read Test BMIC driver reported problem Check that Smart Array firmware and device drivers are up to date
420505 Fibre Array Controller, Random Read Test Cannot open filesystem table Use a more recent version of diagnostics
420303 Fibre Array Controller, Random Read Test CISS driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Fibre Array Controller, Random Read Test Driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Fibre Array Controller, Random Read Test Controller is not supported Check that Smart Array firmware and device drivers are up to date
420710 Fibre Array Controller, Random Read Test Error limit exceeded Replace disk drive or media
420505 Fibre Array Controller, Random Read Test No fibre channel port selected Use a more recent version of diagnostics
420505 Fibre Array Controller, Random Read Test Could not access file Use a more recent version of diagnostics
420505 Fibre Array Controller, Random Read Test Invalid access order Select a different access order for this test
420505 Fibre Array Controller, Random Read Test Invalid parameter list Select different parameters for this test
420710 Fibre Array Controller, Random Read Test Could not access media Replace disk drive or media
420202 Fibre Array Controller, Random Read Test Cannot determine bus speed Check that Smart Array firmware and device drivers are up to date
420202 Fibre Array Controller, Random Read Test Cannot determine bus width Check that Smart Array firmware and device drivers are up to date
420505 Fibre Array Controller, Random Read Test SCSI command is not supported Use a more recent version of diagnostics
420505 Fibre Array Controller, Random Read Test SCSI adapter not implemented Use a more recent version of diagnostics
420710 Fibre Array Controller, Random Read Test Could not transfer SCSI data Check SCSI cables and connectors
420505 Fibre Array Controller, Random Read Test SCSI device not implemented Use a more recent version of diagnostics
420505 Fibre Array Controller, Random Read Test Undefined SCSI adapter Use a more recent version of diagnostics
420505 Fibre Array Controller, Random Read Test Device reported problem Use a more recent version of diagnostics
420505 Fibre Array Controller, Random Read Test Unknown device type Use a more recent version of diagnostics
420202 Fibre Array Controller, Sequential Seek Test BMIC driver reported problem Check that Smart Array firmware and device drivers are up to date
420505 Fibre Array Controller, Sequential Seek Test Cannot open filesystem table Use a more recent version of diagnostics
420303 Fibre Array Controller, Sequential Seek Test CISS driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Fibre Array Controller, Sequential Seek Test Driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Fibre Array Controller, Sequential Seek Test Controller is not supported Check that Smart Array firmware and device drivers are up to date
420710 Fibre Array Controller, Sequential Seek Test Error limit exceeded Replace disk drive or media
420505 Fibre Array Controller, Sequential Seek Test No fibre channel port selected Use a more recent version of diagnostics
420505 Fibre Array Controller, Sequential Seek Test Could not access file Use a more recent version of diagnostics
420505 Fibre Array Controller, Sequential Seek Test Invalid access order Select a different access order for this test
420505 Fibre Array Controller, Sequential Seek Test Invalid parameter list Select different parameters for this test
420710 Fibre Array Controller, Sequential Seek Test Could not access media Replace disk drive or media
420202 Fibre Array Controller, Sequential Seek Test Cannot determine bus speed Check that Smart Array firmware and device drivers are up to date
420202 Fibre Array Controller, Sequential Seek Test Cannot determine bus width Check that Smart Array firmware and device drivers are up to date
420505 Fibre Array Controller, Sequential Seek Test SCSI command is not supported Use a more recent version of diagnostics
420505 Fibre Array Controller, Sequential Seek Test SCSI adapter not implemented Use a more recent version of diagnostics
420710 Fibre Array Controller, Sequential Seek Test Could not transfer SCSI data Check SCSI cables and connectors
420505 Fibre Array Controller, Sequential Seek Test SCSI device not implemented Use a more recent version of diagnostics
420505 Fibre Array Controller, Sequential Seek Test Undefined SCSI adapter Use a more recent version of diagnostics
420505 Fibre Array Controller, Sequential Seek Test Device reported problem Use a more recent version of diagnostics
420505 Fibre Array Controller, Sequential Seek Test Unknown device type Use a more recent version of diagnostics
420202 Fibre Array Controller, Butterfly Seek Test BMIC driver reported problem Check that Smart Array firmware and device drivers are up to date
420505 Fibre Array Controller, Butterfly Seek Test Cannot open filesystem table Use a more recent version of diagnostics
420303 Fibre Array Controller, Butterfly Seek Test CISS driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Fibre Array Controller, Butterfly Seek Test Driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Fibre Array Controller, Butterfly Seek Test Controller is not supported Check that Smart Array firmware and device drivers are up to date
420710 Fibre Array Controller, Butterfly Seek Test Error limit exceeded Replace disk drive or media
420505 Fibre Array Controller, Butterfly Seek Test No fibre channel port selected Use a more recent version of diagnostics
420505 Fibre Array Controller, Butterfly Seek Test Could not access file Use a more recent version of diagnostics
420505 Fibre Array Controller, Butterfly Seek Test Invalid access order Select a different access order for this test
420505 Fibre Array Controller, Butterfly Seek Test Invalid parameter list Select different parameters for this test
420710 Fibre Array Controller, Butterfly Seek Test Could not access media Replace disk drive or media
420202 Fibre Array Controller, Butterfly Seek Test Cannot determine bus speed Check that Smart Array firmware and device drivers are up to date
420202 Fibre Array Controller, Butterfly Seek Test Cannot determine bus width Check that Smart Array firmware and device drivers are up to date
420505 Fibre Array Controller, Butterfly Seek Test SCSI command is not supported Use a more recent version of diagnostics
420505 Fibre Array Controller, Butterfly Seek Test SCSI adapter not implemented Use a more recent version of diagnostics
420710 Fibre Array Controller, Butterfly Seek Test Could not transfer SCSI data Check SCSI cables and connectors
420505 Fibre Array Controller, Butterfly Seek Test SCSI device not implemented Use a more recent version of diagnostics
420505 Fibre Array Controller, Butterfly Seek Test Undefined SCSI adapter Use a more recent version of diagnostics
420505 Fibre Array Controller, Butterfly Seek Test Device reported problem Use a more recent version of diagnostics
420505 Fibre Array Controller, Butterfly Seek Test Unknown device type Use a more recent version of diagnostics
420202 Fibre Array Controller, Random Seek Test BMIC driver reported problem Check that Smart Array firmware and device drivers are up to date
420505 Fibre Array Controller, Random Seek Test Cannot open filesystem table Use a more recent version of diagnostics
420303 Fibre Array Controller, Random Seek Test CISS driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Fibre Array Controller, Random Seek Test Driver reported problem Check that Smart Array firmware and device drivers are up to date
420101 Fibre Array Controller, Random Seek Test Controller is not supported Check that Smart Array firmware and device drivers are up to date
420710 Fibre Array Controller, Random Seek Test Error limit exceeded Replace disk drive or media
420505 Fibre Array Controller, Random Seek Test No fibre channel port selected Use a more recent version of diagnostics
420505 Fibre Array Controller, Random Seek Test Could not access file Use a more recent version of diagnostics
420505 Fibre Array Controller, Random Seek Test Invalid access order Select a different access order for this test
420505 Fibre Array Controller, Random Seek Test Invalid parameter list Select different parameters for this test
420710 Fibre Array Controller, Random Seek Test Could not access media Replace disk drive or media
420202 Fibre Array Controller, Random Seek Test Cannot determine bus speed Check that Smart Array firmware and device drivers are up to date
420202 Fibre Array Controller, Random Seek Test Cannot determine bus width Check that Smart Array firmware and device drivers are up to date
420505 Fibre Array Controller, Random Seek Test SCSI command is not supported Use a more recent version of diagnostics
420505 Fibre Array Controller, Random Seek Test SCSI adapter not implemented Use a more recent version of diagnostics
420710 Fibre Array Controller, Random Seek Test Could not transfer SCSI data Check SCSI cables and connectors
420505 Fibre Array Controller, Random Seek Test SCSI device not implemented Use a more recent version of diagnostics
420505 Fibre Array Controller, Random Seek Test Undefined SCSI adapter Use a more recent version of diagnostics
420505 Fibre Array Controller, Random Seek Test Device reported problem Use a more recent version of diagnostics
420505 Fibre Array Controller, Random Seek Test Unknown device type Use a more recent version of diagnostics
061101 Ide Diskette, Sequential Read Test Could not access media This test failed as a result of the diskette drive not having a formatted diskette present in the diskette drive. Correct the error condition by placing media into the diskette drive, and re-run this test. If there was media present in the drive when the test was last run, then the drive requires replacement.
061102 Ide Diskette, Sequential Read Test Could not seek block Replace and/or format drive media. If this does not correct the problem, the drive may require replacement.
061103 Ide Diskette, Sequential Read Test Could not read block Replace and/or format drive media. If this does not correct the problem, the drive may require replacement.
061201 Ide Diskette, Butterfly Read Test Could not access media This test failed as a result of the diskette drive not having a formatted diskette present in the diskette drive. Correct the error condition by placing media into the diskette drive, and re-run this test. If there was media present in the drive when the test was last run, then the drive requires replacement.
061202 Ide Diskette, Butterfly Read Test Could not seek block Replace and/or format drive media. If this does not correct the problem, the drive may require replacement.
061203 Ide Diskette, Butterfly Read Test Could not read block Replace and/or format drive media. If this does not correct the problem, the drive may require replacement.
061301 Ide Diskette, Random Read Test Could not access media This test failed as a result of the diskette drive not having a formatted diskette present in the diskette drive. Correct the error condition by placing media into the diskette drive, and re-run this test. If there was media present in the drive when the test was last run, then the drive requires replacement.
061302 Ide Diskette, Random Read Test Could not seek block Replace and/or format drive media. If this does not correct the problem, the drive may require replacement.
061303 Ide Diskette, Random Read Test Could not read block Replace and/or format drive media. If this does not correct the problem, the drive may require replacement.
061501 Ide Diskette, Sequential Seek Test Could not access media This test failed as a result of the diskette drive not having a formatted diskette present in the diskette drive. Correct the error condition by placing media into the diskette drive, and re-run this test. If there was media present in the drive when the test was last run, then the drive requires replacement.
061502 Ide Diskette, Sequential Seek Test Could not seek block Replace and/or format drive media. If this does not correct the problem, the drive may require replacement.
061601 Ide Diskette, Butterfly Seek Test Could not access media This test failed as a result of the diskette drive not having a formatted diskette present in the diskette drive. Correct the error condition by placing media into the diskette drive, and re-run this test. If there was media present in the drive when the test was last run, then the drive requires replacement.
061602 Ide Diskette, Butterfly Seek Test Could not seek block Replace and/or format drive media. If this does not correct the problem, the drive may require replacement.
061701 Ide Diskette, Random Seek Test Could not access media This test failed as a result of the diskette drive not having a formatted diskette present in the diskette drive. Correct the error condition by placing media into the diskette drive, and re-run this test. If there was media present in the drive when the test was last run, then the drive requires replacement.
061702 Ide Diskette, Random Seek Test Could not seek block Replace and/or format drive media. If this does not correct the problem, the drive may require replacement.
061801 Ide Diskette, Sequential RWRC Test Could not access media This test failed as a result of the diskette drive not having a formatted diskette present in the diskette drive. Correct the error condition by placing media into the diskette drive, and re-run this test. If there was media present in the drive when the test was last run, then the drive requires replacement.
061802 Ide Diskette, Sequential RWRC Test Could not seek block Replace and/or format drive media. If this does not correct the problem, the drive may require replacement.
061803 Ide Diskette, Sequential RWRC Test Could not read block Replace and/or format drive media. If this does not correct the problem, the drive may require replacement.
061804 Ide Diskette, Sequential RWRC Test Could not write block Replace and/or format drive media. If this does not correct the problem, the drive may require replacement.
061901 Ide Diskette, Butterfly RWRC Test Could not access media This test failed as a result of the diskette drive not having a formatted diskette present in the diskette drive. Correct the error condition by placing media into the diskette drive, and re-run this test. If there was media present in the drive when the test was last run, then the drive requires replacement.
061902 Ide Diskette, Butterfly RWRC Test Could not seek block Replace and/or format drive media. If this does not correct the problem, the drive may require replacement.
061903 Ide Diskette, Butterfly RWRC Test Could not read block Replace and/or format drive media. If this does not correct the problem, the drive may require replacement.
061904 Ide Diskette, Butterfly RWRC Test Could not write block Replace and/or format drive media. If this does not correct the problem, the drive may require replacement.
062001 Ide Diskette, Random RWRC Test Could not access media This test failed as a result of the diskette drive not having a formatted diskette present in the diskette drive. Correct the error condition by placing media into the diskette drive, and re-run this test. If there was media present in the drive when the test was last run, then the drive requires replacement.
062002 Ide Diskette, Random RWRC Test Could not seek block Replace and/or format drive media. If this does not correct the problem, the drive may require replacement.
062003 Ide Diskette, Random RWRC Test Could not read block Replace and/or format drive media. If this does not correct the problem, the drive may require replacement.
062004 Ide Diskette, Random RWRC Test Could not write block Replace and/or format drive media. If this does not correct the problem, the drive may require replacement.
062101 Ide Diskette, Floppy Remove Test Media not present in drive This test failed as a result of the diskette drive not having a formatted diskette present in the diskette drive. Correct the error condition by placing media into the diskette drive, and re-run this test. If there was media present in the drive when the test was last run, then the drive requires replacement.
062102 Ide Diskette, Floppy Remove Test Undefined Message Drive requires replacement.
062201 Ide Diskette, Floppy Write Protect Test Media not present in drive This test failed as a result of the diskette drive not having a formatted diskette present in the diskette drive. Correct the error condition by placing media into the diskette drive, and re-run this test. If there was media present in the drive when the test was last run, then the drive requires replacement.
062202 Ide Diskette, Floppy Write Protect Test Undefined Message Drive requires replacement.
174301 Ide Disk, Sequential Read Test Could not seek block Drive requires replacement.
174302 Ide Disk, Sequential Read Test Could not read block Drive requires replacement.
174401 Ide Disk, Butterfly Read Test Could not seek block Drive requires replacement.
174402 Ide Disk, Butterfly Read Test Could not read block Drive requires replacement.
174501 Ide Disk, Random Read Test Could not seek block Drive requires replacement.
174502 Ide Disk, Random Read Test Could not read block Drive requires replacement.
174601 Ide Disk, Sequential Seek Test Could not seek block Drive requires replacement.
174701 Ide Disk, Butterfly Seek Test Could not seek block Drive requires replacement.
174801 Ide Disk, Random Seek Test Could not seek block Drive requires replacement.
174901 Ide Disk, Sequential RWRC Test Could not seek block Drive requires replacement.
174902 Ide Disk, Sequential RWRC Test Could not read block Drive requires replacement.
174903 Ide Disk, Sequential RWRC Test Could not write block Drive requires replacement.
175001 Ide Disk, Butterfly RWRC Test Could not seek block Drive requires replacement.
175002 Ide Disk, Butterfly RWRC Test Could not read block Drive requires replacement.
175003 Ide Disk, Butterfly RWRC Test Could not write block Drive requires replacement.
175101 Ide Disk, Random RWRC Test Could not seek block Drive requires replacement.
175102 Ide Disk, Random RWRC Test Could not read block Drive requires replacement.
175103 Ide Disk, Random RWRC Test Could not write block Drive requires replacement.
175201 Ide Disk, Self Test Quick Undefined Message The drive should be replace as soon as possible.
175202 Ide Disk, Self Test Quick Undefined Message The drive should be replace as soon as possible.
175203 Ide Disk, Self Test Quick Undefined Message This test is not applicable for this drive.
175205 Ide Disk, Self Test Quick Undefined Message The drive should be replace as soon as possible.
175301 Ide Disk, Self Test Extended Undefined Message The drive should be replace as soon as possible.
175302 Ide Disk, Self Test Extended Undefined Message The drive should be replace as soon as possible.
175303 Ide Disk, Self Test Extended Undefined Message This test is not applicable for this drive.
175304 Ide Disk, Self Test Extended Undefined Message The drive should be replace as soon as possible.
175401 Ide Disk, Reset Test Undefined Message Drive requires replacement.
181201 Ide CDROM, Sequential Read Test Could not access media This test failed as a result of the diskette drive not having a formatted diskette present in the diskette drive. Correct the error condition by placing media into the diskette drive, and re-run this test. If there was media present in the drive when the test was last run, then the drive requires replacement.
181202 Ide CDROM, Sequential Read Test Could not seek block Drive requires replacement.
181203 Ide CDROM, Sequential Read Test Could not read block Drive requires replacement.
181301 Ide CDROM, Butterfly Read Test Could not access media This test failed as a result of the diskette drive not having a formatted diskette present in the diskette drive. Correct the error condition by placing media into the diskette drive, and re-run this test. If there was media present in the drive when the test was last run, then the drive requires replacement.
181302 Ide CDROM, Butterfly Read Test Could not seek block Drive requires replacement.
181303 Ide CDROM, Butterfly Read Test Could not read block Drive requires replacement.
181401 Ide CDROM, Random Read Test Could not access media This test failed as a result of the diskette drive not having a formatted diskette present in the diskette drive. Correct the error condition by placing media into the diskette drive, and re-run this test. If there was media present in the drive when the test was last run, then the drive requires replacement.
181402 Ide CDROM, Random Read Test Could not seek block Drive requires replacement.
181403 Ide CDROM, Random Read Test Could not read block Drive requires replacement.
181501 Ide CDROM, Sequential Seek Test Could not access media This test failed as a result of the diskette drive not having a formatted diskette present in the diskette drive. Correct the error condition by placing media into the diskette drive, and re-run this test. If there was media present in the drive when the test was last run, then the drive requires replacement.
181502 Ide CDROM, Sequential Seek Test Could not seek block Drive requires replacement.
181601 Ide CDROM, Butterfly Seek Test Could not access media This test failed as a result of the diskette drive not having a formatted diskette present in the diskette drive. Correct the error condition by placing media into the diskette drive, and re-run this test. If there was media present in the drive when the test was last run, then the drive requires replacement.
181602 Ide CDROM, Butterfly Seek Test Could not seek block Drive requires replacement.
181701 Ide CDROM, Random Seek Test Could not access media This test failed as a result of the diskette drive not having a formatted diskette present in the diskette drive. Correct the error condition by placing media into the diskette drive, and re-run this test. If there was media present in the drive when the test was last run, then the drive requires replacement.
181702 Ide CDROM, Random Seek Test Could not seek block Drive requires replacement.
181801 Ide CDROM, Reset Test Undefined Message Drive requires replacement.
181901 Ide CDROM, Tray Test Undefined Message Drive requires replacement.
010711 CMOS, CMOS Test CMOS RAM rd/wr/cmp test This test is designed to catch errors associated with the device`s address bus: address lines that are shorted or open, and address lines that are tied together. These errors exhibit themselves by not allowing access to all locations in the device. In addition, multiple addresses result in accesses to the same physical location. The test can also detect stuck-at, transition, and coupling memory faults. The test starts at location 0Eh to avoid corrupting the Real Time Clock. This error would indicate that the board on which the CMOS is on to be replaced. Please call HP Warranty Support for assistance (number can be found in "Help").
800404 POST, POST Test POST problem reported Correct the underlying problem and then either mark the pending error within the Integrated Management Log as "repaired" or clear the entire Log
760000 Fan Slot, Fan Status Test Fan problem exists Undefined Repair
760003 Fan Slot, Fan Status Test Fan missing Undefined Repair
760001 Fan Slot, Fan Detect Test Fan missing Undefined Repair
762000 Temperature Device, Temperature Caution Test Temperature overheating Undefined Repair
760002 UID Device, UID Test UID state unchanged Undefined Repair
764000 Power Supply Module, Power Supply Status Test Power supply not powered Undefined Repair
115025 USB Device, Root Hub Test Unable to detect root hub Undefined Repair
249068 Video Device, Blt Test Blitter video hardware Blitter video hardware failure. Either the driver(s) for the device are not installed correctly or the display adapter needs to be replaced.
249069 Video Device, Line Test Line drawing subsystem Line drawing subsystem failure. Either the driver(s) for the device are not installed correctly or the display adapter needs to be replaced.
249074 Video Device, Memory Test Adapter video memory The video memory verification test failed. Either the display adapter is bad or it could not be set to the mode needed to run the test.
249078 Video Device, Mode Test Mode test Unable to set mode on video adapter. Either the driver reported an incorrect video capability or the display adapter needs to be replaced.
249072 Video Device, Monitor Identification Test Monitor was not detected A monitor was not detected. Check cabling, replace monitor or video adapter
249078 Video Device, Pallete Test Mode test Unable to set mode on video adapter. Either the driver reported an incorrect video capability or the display adapter needs to be replaced.
249071 Video Device, Polygon Test Polygon drawing subsystem Polygon drawing subsystem failure. Either the driver(s) for the device are not installed correctly or the display adapter needs to be replaced.
249070 Video Device, Rectangle Test Rectangle drawing subsystem Rectangle drawing subsystem failure. Either the driver(s) for the device are not installed correctly or the display adapter needs to be replaced.
249073 Video Device, 3D Rendering Test 3D acceleration hardware The 3D acceleration hardware of the display adaptor is not functioning properly. Either the driver(s) for the device are not installed correctly or the display adapter needs to be replaced.
249073 Video Device, 3D Texture Test 3D acceleration hardware The 3D acceleration hardware of the display adaptor is not functioning properly. Either the driver(s) for the device are not installed correctly or the display adapter needs to be replaced.
249073 Video Device, 3D Transparency Test 3D acceleration hardware The 3D acceleration hardware of the display adaptor is not functioning properly. Either the driver(s) for the device are not installed correctly or the display adapter needs to be replaced.
249068 Video Device, Animated Blt Test Blitter video hardware Blitter video hardware failure. Either the driver(s) for the device are not installed correctly or the display adapter needs to be replaced.